7.
TEST
EQUIPMENT
REQUIRED
FOR
SERVICING
Table 1 lists the test equipment required for servicing the Model 1060 Stereo Console Amplifier.
The
wattmeter,
ac
voltmeter,
and
variac
may
be assembled
as a test
fixture
as shown
schematically in Figure 1, and the load resistors and ac ammeter may be assembled into a second
test fixture as shown in Figure2.
Manufacturer and Model No.
Item
:
Use
(or equivalent)
Weston
Model
CVQ-100P
(NOTE:
Less than 0.02 per-
cent
residual
distortion
Is re-
quired.)
Tektronix,
Model
503;
Data,
Model 555
|
RCA
Senior
Volt-Ohmyst,
Model WV-98C
Simpson, Model 390
Audio Oscillator
Sinewave
and squarewave
Sig-
nal source.
Waveform
analysis and
trou-
bleshooting.
Oscilloscope
surements.
sumption of amplifier.
(0 to 10 amps)
Line Voltmeter
(0 to 150 vac)
Variable Autotransformer
(0 to 140 vac, 10 amps)
Shorting Plug
Monitors amplifier output un-
der short circuit condition.
Commercial Grade
Monitors potential of primary
power to amplifier.
Powerstat, Model 116B
Adjusts level of primary power
to amplifier.
Use
phono
plug
with
600
ohms
across
center
pin and
shell.
Commercial
Grade
Shorts
amplifier
input
to
eliminate noise pickup.
Discharges power supply filter
capacitors prior to disassembly
or resistance measurements.
Power Supply Bleeder
Resistor (10 ohms at 1 W)
Commercial Grade
Output Load Resistor
(8Q + 0.5%, 250W)
Output Load Resistor
(42 + 0.5%, 250W)
Output Load
Capacitor (0.5 mfd)
AC Power Control Box
Provides 8-ohm load for ampli-
fier output termination.
Commercial Grade
Provides 4-ohm load for ampli.
fier output termination.
Provides
capacitive
load for
instability checks.
Mylar
Optional
Item.
Fabricate
in
accordance with Figure1.
Monitors and controls primary
power for amplifier.
Optional
Item.
Fabricate
in
accordance with Figure2.
Provides
various
amplifier
loads and can monitor shorted
output.
Amplifier Output