THERMOSTAHL MPB 60 Installation And User Manual

Pellet burner

Advertisement

Quick Links

PELLET BURNER
MPB 60/80
INSTALLATION AND USER MANUAL
VERSION:
1.3
UPDATE:
02.03.2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MPB 60 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for THERMOSTAHL MPB 60

  • Page 1 PELLET BURNER MPB 60/80 INSTALLATION AND USER MANUAL VERSION: UPDATE: 02.03.2022...
  • Page 2: Table Of Contents

    Contents Warnings, Cautions and Notes ................3 1.1. Document information ..................3 Function principle ....................4 Technical specifications ..................4 Boiler ........................ 5 Chimney ......................5 Electrical connections ..................6 Controller ......................7 7.1. General description ................... 7 7.2. Description of buttons ..................7 Operation functions ...................
  • Page 3: Warnings, Cautions And Notes

    1. Warnings, Cautions and Notes Read the safety instructions carefully before Electric switch must be used to the installation. Always follow the safety power supply cable as an emergency stop instructions during installation and during maintenance Installation, operation, service, and other work Always follow the instructions for operations must be carried out by qualified personnel in and service.
  • Page 4: Function Principle

    The burner is also equipped with the self-control systems (detecting the malfunction of the temperature's sensors) and mechanisms monitoring the furnace's work preventing from going beyond the range of safety for the installation of the central heating. 3. Technical specifications Type MPB 60 MPB 80 Heat output 20-60 kW 40-80 kW...
  • Page 5: Boiler

    4. Boiler It is important to check that the combustion chamber in the boiler is big enough to ensure that the flame does not come in contact with the water-cooled walls. Verify that the boiler’s capacity range complies with the burner. There must be enough space for the ash to accumulate. The exhaust gas channels should not be so narrow that they can easily be clogged with ash.
  • Page 6: Electrical Connections

    6. Electrical connections...
  • Page 7: Controller

    7. Controller 7.1. General description Description: • Diodes signalizing the status of outputs and the working mode of the driver, • LCD screen used for communication between the device and the user, • Buttons steering the driver's work. 7.2. Description of buttons Button Function Changes the burner's working mode –...
  • Page 8: Operation Functions

    8. Operation functions After switching the burner on, it is appeared on the LCD screen the program's logo defining the type of the driver and the version of the current software While activating, the burner carries out a test of the connected sensors. In case of one lacking, on the screen appears an appropriate message (---).
  • Page 9: Parameters

    FUNCTION'S NAME DESCRIPTION OF FUNCTIONS STOP Burner stopped. Filling the feeder. FEEDER FILLING Filling stops automatically after about 10 minutes. The burner is on Ignition process, which mean that has fed with ignition dose IGNITION of pellet, the heating element (igniter) and the air fan are working. The mode would be automatically changed after detecting a flame by the sensor.
  • Page 10 WUW BUFFER SETTINGS (B) FUNCTION FUNCTION SETTING SETTING MANUFACTURER NAME UNIT RANGE SETTING WUW BUFFER ºC 20 - 80 TEMPERATUR WUW SURPLUS ºC 5 - 20 TEMPERATURE Yes/No PRIORITY BURNER SETTINGS (C) FUNCTION FUNCTION SETTING SETTING MANUFACTURER NAME UNIT RANGE SETTING BURNER POWER 10 - 80...
  • Page 11: Room Thermostat

    DEVICE SETTINGS (D) FUNCTION FUNCTION SETTING SETTING MANUFACTURER NAME UNIT RANGE SETTING Polish/ LANGUAGE English/ English* SETTINGS German/Greek/ Serbian/... FACTORY Yes/No SETTINGS ENABLE SERVICE 000 - 999 MODE 10. Room thermostat The room thermostat (or a timer) can be connected on the connector which is at the back of the controller, by replacing the “bridge (or on the PINs 1&2 in the controller).
  • Page 12: Stop Of The Burner

    3. By pressing the button “MODE/ “ once changes the operation from “Stop” to “ignition”. By pressing the button “MODE/ “ changes the operation from “Ignition” to “Automatic”. 4. In “Automatic mode”, starts the operation of the burner. 5. When the photo sensors detects fire, then the burner starts its “Work” by increasing its power gradually to the power it has been set (i.e 30kW) 6.
  • Page 13: Restart The Burner After An Error

    14. Restart the burner after an error Turn off the burner by using the electric switch ON/OFF. Open the boiler's door and check the burner tube. 3. Remove any ashes and impurities from burner fire chamber. 4. Close the door and switch on the controller by using the electric switch the burner is connected By pressing the button “MODE/ “...
  • Page 14: Errors

    17. Errors Indication Description Solution / 1. The driver starts up relevant emergency procedures for every sensor in order to prevent the CH:!!!! Malfunction water boiler from working beyond the safe range for the WUW:!!!!!! temperature sensors installation of the central heating STOP 2.
  • Page 15 THERMOSTAHL ROMANIA HEATING SYSTEMS S.R.L. DRUMUL OSIEI 57-59, sector 6 Bucharest 062395, Romania www.thermostahl.ro...