Download Print this page

Technical Data; Data For Hazardous Areas - E.L.B. Ex-Geräte TT-108 Manual

Advertisement

Silicone Keyboard TT-108
3

Data for Hazardous Areas:

Type: TT-108
-
-
II 2 G Ex ia IIC T4
II 2 D Ex tD A21 IP68 T79° C
-
-20° C < T
-
IBExU 05 ATEX 1084 X
-
Meaning of the Marking for Hazardous Areas:
II
2
G Ex ia
IBExU 05 ATEX 1084 X
Feet for grounding
The metal bottom of the case must be grounded to avoid "isolated capacities"
to be charged. Therefore the two feet of the case close to the cable outlet are
electrically connected with the metal bottom of the case, which must have a
conductive connection with the desktop. The user is responsible for the
sufficient ground connection of the desktop.
19.03.2014

Technical Data

< +50° C
amb
II
IIC T4
© E.L.B. Ex-Geräte Bachmann GmbH
-
Technical Documentation
- U
≤ 5,4 V
i
- I
≤ 250 mA
i
- P
≤ 1,2 W
i
- ΣC
≤ 13 µF
i
- ΣL
≤ negligible
i
2
D Ex tD A21 IP68 T79° C
Page 3