INSTRUCTION MANUAL
ISOLATION AMPLIFIER
BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■ PACKAGE INCLUDES:
Amplifier ....................................................................... (1)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■ POWER INPUT RATING & OPERATIONAL RANGE
• Power Supply
Operational voltage range: 11.5 – 16V DC
Power consumption: approx. 7mA DC (no load)
Install the filter for the power supply as indicated below.
+15V
+
POWER
10µF
COM
■ ENVIRONMENT
• Indoor use
• When heavy dust or metal particles are present in the air,
install the unit inside proper housing with sufficient ven-
tilation.
TERMINAL CONNECTIONS
■ EXTERNAL DIMENSIONS mm (inch)
MAX 53 (2.09)
1
6
2.54 (.1)
12.7 (.5)
17.78 (.7)
20.32 (.8)
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
(output isolation)
560µH
6
+
10µF
5
13
17
0.5 (.02)
0.25
(.01)
10.16 (.4)
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +70°C
(14 to 158°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
• Do not install cables (power supply, input and output)
close to noise sources (relay drive cable, high frequency
line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ INSTALLING THE MODULE
When it is installed on the printed wiring board, land diam-
eter ø1.5 and through-hole ø0.9 are recommended.
■ AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
• With voltage output, do not leave the output terminals
shortcircuited for a long time. The unit is designed to en-
dure it without breakdown, however, it may shorten ap-
propriate life duration.
CHECKING
1) Terminal wiring: Check that wiring is correctly connect-
ed according to the connection diagram.
2) Power input voltage: Check voltage across the pins.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
MAX 18 (.71)
PIN ASSIGNMENT
1
2
3
4
5
6
13
14
15
16
17
5.65
(.22)
20VS5-140
20VS5-140
MODEL
INPUT (+)
NC
NC
INPUT (–)
POWER SUPPLY (–)
POWER SUPPLY (+)
REFERENCE VOLTAGE SOURCE (+15V)
REFERENCE VOLTAGE SOURCE (–15V)
REFERENCE VOLTAGE SOURCE (COM (0V))
OUTPUT (COM (–))
OUTPUT (COM (+))
EM-4417 Rev.2
P. 1 / 2

Advertisement

loading
Need help?

Need help?

Do you have a question about the 20VS5-140 and is the answer not in the manual?

Questions and answers

Summary of Contents for MG 20VS5-140

  • Page 1 REFERENCE VOLTAGE SOURCE (COM (0V)) OUTPUT (COM (–)) 0.5 (.02) 2.54 (.1) 0.25 OUTPUT (COM (+)) (.01) 12.7 (.5) 17.78 (.7) 10.16 (.4) 5.65 (.22) 20.32 (.8) MG CO., LTD. www.mgco.jp EM-4417 Rev.2 P. 1 / 2 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 2 50%, 75% and 100% input signal. Check that the output signal for the respective input signal remains within accu- racy described in the data sheet. MG CO., LTD. www.mgco.jp EM-4417 Rev.2 P. 2 / 2 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...