Contents INTRODUCTION ................................1 NOTICE ......................................1 USER LIMITATION ................................... 1 Safety Information ..............................2 Read this first ! ! ..................................2 Software License Agreement .............................. 3 Chapter 1 Before Using the Product ........................4 1.1 Composition ..................................4 1.2 Outline ....................................4 1.3 Explanation of Each Part ...............................
NOTICE ■ It is prohibited to reprint or duplicate any part or the whole of this instruction manual without prior permission from LINEEYE. ■ The contents of this instruction manual and specifications of the products are subject to change without notice.
Safety Information Read this first ! ! This Safety Information includes the important information in order to not only have you learn the right way to use the analyzer, but also prevent you from causing damage to people and property. Before using, please read the main contents after you understand the following contents (symbols and marks).
5. Limitation of Liability In no event shall LINEEYE or its licensors be liable for loss of business or profits, or for any direct, indirect, incidental or consequential damages arising from products of this software or the related software. Besides LINEEYE shall not be liable damages arising from the equipment or the medium.
Instruction Manual(This book): 1 Warranty Customer Registration Card:: 1 * Please contact LINEEYE distributor or us if you find any insufficient part of any damage to the product caused by transportation. * Please keep the box carefully to use it when sending the product back to us for repair etc.
Self-check error, Unusual error (*2) *1: Do not remove the SD card while lighting. *2: Contact LINEEYE distributors or LINEEYE for support. CH1/CH2: Indicate the logic status of CH1/CH2 Line. U1/U2: Able to light the U1 (green) /U2 (red) by trigger actions.
Page 8
5) USB Connector Use the included USB cable to connect the host PC. <Dust-proofing cover> There is a dust-proofing cover on the SD card slot and USB connector. To remove the SD card, open the cover as following. Also, it is possible to open the cover for USB connector only as following. 6) DC Jack Connect the power supply when using the analyzer as a Data Logger.
1. Do not connect the analyzer to the USB port of PC before the driver installation. 2. Download the USB driver compatible with the analyzer from the LINEEYE website, Unzip to a proper folder. (The driver is also included in the CD attached to the product.) Supported OS are Windows 10/8.1/7...
9. Connect the analyzer device to the PC. The installation is completed. Above is the installation for Windows 10. It will be almost same for other Windows OSs. 2.3 Installation Guide ■Install 1. Execute “setup.exe” in the attached CD. If the PC (to which you want to install the software) does not have a CD-ROM drive, copy it to a storage device such as USB flash using another PC which has a CD-ROM drive to bring it to the PC and execute it.
Chapter 3 Basic Operation 3.1 Connection ■ Protocol Analyzer Mode 1). Connect the USB cable to the analyzer 2). Connect USB A connector to the PC which installed the analysis software. 3). Connect the analyzer and target devices using the LE-25M3A-1. ●...
Page 12
○ Measuring Port * Dsub25 pin connector ○ CAN/LIN DSUB cable (LE-25M3A-1) Pin No. Color Signal Meaning Orange (black dot) Signal Ground Gray (black dot) CAN1_H CAN Signal (channel1) Gray (red dot) CAN1_L White (black dot) CAN2_H CAN signal (channel2) White (red dot) CAN2_L Yellow (black dot)
3.2 Configuration of Analysis Software ■ Data Window Execute the analysis software. From [Start] menu of Windows, go to [All programs] -> [LINEEYE] -> [LE-LINK27]. Execute “LE-LINK27” and then following display will be appeared. 1) → 2) → 3) →...
Page 14
● Measurement Data Select the saving folder and file size of measured data. [A folder to save the monitor data] This folder is for saving the measured data. To change the settings, click “Change” button. Then the window to select a folder will be appeared.
Page 15
■ Analyzer Settings Click “ ” on the tool bar of the data window (or click “Measurement” -> “Measurement setting”) to set the target bus, speed and so on. On the measurement setting window, every time you change the setting on the left side of the window, the contents of the setting (on the right side of the window) will be changed.
● Logger Setting [Data Save] Set the file size and number of files to save for a Data Logger Mode. [Auto RUN/STOP] Set the starting time and ending time of the auto-measurement. Chapter 4 Interface Setup Select a port for monitoring. ■...
Chapter 5 Monitor Function The purpose of the monitor function is to record communication data into files without affecting the communication lines. The results will be displayed as CAN/LIN frames. Not only communication data but also time stamp and ex- ternal signals are recorded.
Page 18
● ID Filter Select the ID filter from “OFF”(invalid), “Acceptance”, “Pass”, “Cut”, “Pass & Cut”, or “Acceptance & Pass & Cut”. ・ Acceptance Captures the frames which have corresponding ID by a hardware filter. You can set bit-by-bit ( “0” , “1” , “*” , (Don’ t care)) from high-order bit by acceptance configuration tab.
Page 19
・ Cut NOT capture the frames which have corresponding ID by a software filter. Select standard format of extended format at the cut configuration tab and set the ID by HEX (“0” - “F”, “*”, (Don’t care)). (You can set up to 8 items) Configure values within the scope of ID:0 –...
● Frame End Select the frame end from “Time” (non-communication time exceeds the value set in “Frame End Time”) or “ID” (value of DLC field). Select “ID” for normal operation. If selecting “ID”, select DLC and method of calculating checksum for each ID. ●...
Page 21
■ Stop Measuring Click “ ” on the tool bar of data window (or click “Measurement” -> “Stop measurement”). It is able to scroll data after the measurement in the Data Monitor display. Data will be saved into the specified folder set in the configuration settings.
Page 22
● Data Window Display Meaning Time Displays the time when the frame is received. (time stamp) Displays the difference of time stamps compared to the previous time stamp. deltaT (refer to “5.4 Difference of Time Stamp”) Displays the channel received. (1: CH1, 2: CH2) Break Displays the number of bit for Sync Break width for LIN.
5.3 Watch Data Display It is able to display only specific ID frames while measuring. Only the latest data will be displayed and update it every one second. ■ Setting of Watch Data Display Click “ ” on the tool bar of the data window (or “tool” -> “Watch Data settings”). Set the target channels and ID.
5.4 Difference of Time Stamp <Standard Time Stamp> <Difference of Time Stamp> There are two kinds of time stamp. One is the arrival time of frame. And, the other is the elapsed time from the previous frame. From top menu, go to “Tool” -> “Deference Timestamp”. 5.5 Timer/Counter It is able to check the timer/counter satisfied by the trigger conditions.
5.6 Analog Waveform Display Display the analog waveform at the specified sampling cycle. ■ Analog mode setting Select “ANALOG” (Analog mode) at Function, then select sampling cycle (min.1ms, max.10min). * When selecting Analog mode, time stamp resolution can be selected from [Hr:Min:Sec] or [Min:Sec:x1ms]. Refer to “3.2 Configuration of Analysis Software ■...
Chapter 6 Useful Functions 6.1 Trigger Function Trigger function is to start a specific action upon occurrence of a specific event as the trigger. A perplexing flow of data, which is not easy to be analyzed in the normal monitor operation, is analyzed on the basis of occurrence of the specific event.
Page 27
<Example of ID setting> ID28-24 : - - - 0 0 0 0 0 CAN expansion format it “ID00000023”. ID23-16 : 0 0 0 0 0 0 0 0 ID16-8 : 0 0 0 0 0 0 0 0 ID7-0 : 0 0 1 0 0 0 1 1 CAN standard format is “ID023”.
Page 28
● Trigger Action Eight sets of trigger actions can be set. 1). Stop Measurement will be stopped automatically. Delay time from the occurrence of the trigger until the end of measurement can be set. Quick: Stop the measurement immediately as trigger occurs. Before: Stop the measurement after capturing 6K characters after satisfaction of trigger.
6.2 Timer/Counter The Timer/Counter function, in conjunction with the trigger function, measures the elapsed time since a specific factor occurred, and counts the number of occurrences of a specific factor (set timer/counter as a trigger action). Also, it is able to set the timer/counter as a trigger condition. (refer to “5-5 Timer/Counter”...
6.4 Search Function Click “ ” button on the tool bar of the data window. ● Search Conditions 1). Trigger Search the frame, which satisfies the trigger condition 2). Error Search Break error (LIN), Synch error (LIN), Parity error (LIN), Checksum error (LIN/ CAN), Framing error (LIN) and Error frame (CAN).
Page 31
4). Remote Select the CAN remote frame for a specific channel. [Target]: Select the target channel. [ID 28-0]: Select the target ID in bit. <CAN> Expansion format: ID28-ID0 Standard format: ID28-ID18 (ID17-ID0 have to be “don’t care”.) 5). Time stamp Search the time stamp of the designated time.
6.5 Text Conversion Measured data can be converted into text file or CSV file. Click “ ” on the tool bar of the data window (or “Tool” -> “Text Conversion”). ■ Text Conversion [Folder] Select the file to convert into text. [Conversion Options] Select the type of conversion.
Chapter 7 Data Logger Mode According to the configuration settings in the SD card, analyzer can record data for long hours without a PC. 7.1 Preparation of Data Logger Mode Click “ ” on the tool bar of the data window (or click “Measurement” -> “Measurement setting”). ■...
* The analyzer will not record data if there is not the SD card with configuration data. <Attention> LE-270A supports 8GB SD card. The analyzer will not start operation if using above capacity of the SD card. 3). Supply the power to the analyzer using the AC adapter or power cable (SIH-2PG). LED of POWER/ ERROR will be lighting in orange.
7.3 Auto Run/Stop Function The analyzer can start/end measuring at the specified date. Set “Auto RUN/STOP” using the “LE-LINK27”. ● Mode [Monthly]: Start measuring at the specified time every month. [Daily]: Start measuring at the specified time every day. [Hourly]: Start measuring at the specified time every hour. ●...
Chapter 8 Update Firmware You can update to the latest firmware by the PC, which installed the USB driver. The latest firmware will be available from the LINEEYE website. Connect the analyzer to the PC and execute “LE8FIRM.exe” and follow the instruction.
Page 37
5). A note for updating firmware will be displayed. Read it carefully and click [Start]. The firmware loader will start operating. The LED of POWER/ERROR will be lighted Off and LED of RUN/ACT will be lighted On while the firmware loader is operating.
Chapter 9 Specifications 9.1 Interface (CAN/LIN/External Input) Dsub 25pin connector is for the port of CAN, LIN and external input signal. Pin NO Signal name Function BATT LIN Battery Power Signal Ground Signal Ground EXIN1 External Input 1 EXIN2 External Input 2 EXIN3 External Input 3 EXIN4...
9.3 Specifications Interface CAN: Comfort to ISO11898 standard, TJA1050/ISO11519-2, TJA1054. (Switch by the built-in relay) LIN: Comfort to ISO9141 standard. TJA1021 Connector DSUB 25 pin male connector #4-40UNC Number of Channels 2 channels of CAN or LIN, or 1 CAN and 1 LIN Protocol CAN, Device Net, LIN (Rev1.1, 1.2, 1.3, 2.0, 2.1) Baud Rate...
9.4 Options * Wide input AC adapter: 6A-181WP09: Power supply for Data Logger mode, DC9V center (+) * CAN/LIN water-proofing cable: LE-25M3WP-2: Water-proofing monitor cable (2m) * Clip cable: LE-9LP2: CAN/LIN clip monitor cable. * DIN rail mounting plate: LE-DIN13: To connect analyzer on the 35mm DIN rail. LE-25M3WP-2 DSUB 25pin All signal lines of measurement connectors on the...
* LINEEYE will repair the product according to the warranty. * After the warranty period, LINEEYE will repair the product for you to use the functions properly at your own expense. If your product needs to be repaired, please tell us the model name, serial number, purchased date, and the details of problems.
Page 44
Please register your product for further support. We will provide you the firmware update information and sales information etc. LINE EYE CO., LTD. 4F., Marufuku Bldg., 39-1Karahashi Nishihiragaki-cho, Minami-ku, Kyoto, 601-8468 Japan Phone: 81-75-693-0161 Fax: 81-75-693-0163 URL https://www.lineeye.com Email :info@lineeye.co.jp M-B427AE/LE...