(1) Setting method
* While holding the 'VOL UP' and 'V.SEL' keys depressed, reset the unit.
(2) Common contents
» The TV source is selected.
* The seek mode is set to auto mode.
* The screen mode is set to full-size.
;
+ Pressing the ADJ key in the MENU screen writes the maximum and minimum stop positions of the mechanism tilting/sliding in the
EEPROM.
* Adjusting TOUCH in the SET UP screen writes the reference points (2 points) of the touch panel in the EEPROM.
* When writing in the EEPROM is finished normally, the beep tone is generated twice.
« An error occurrence causes the beep tone to be generated 4 times.
* When a screen other than the picture window is touched, a cross-cursor is displayed.
* The transmitter can be switched ON/OFF using the MODE key on the remote control unit (the transmitter is usually OFF).
* The diversity can be switched ON/OFF using the V.SEL key on the remote control unit (it is usually ON).
* Pressing the SP_MODE key on the remote control unit calls the touch panel adjustment screen.
* Clicking ANGLE, SLIDE, BRT, TIN, COL, CONT or BLK once switches the function between Full-down <=> Center <=> Full-up.
+ Short press of a key causes the beep tone to be generated.
* Display after power ON:
German CH9.
(3) Initial preset channel value
TV Format | Country
Initial Preset CH
Preset No.
CH No.
PAL-B/G
|Germany
TV Format
Initial Preset CH
Preset No.
|©|@[@|@|©|©
TV Format
Initial Preset CH
SECAM-L
Preset No. | @ L@l@/@1o
©
3 | 8 |48|69| 2 |
CH No.
Initial Preset CH
PresetNo.
|©|@/|@|@| ol©
| CHNo. | 2 |10/ 43/69/14 [1 |
| ©
Preset No. | D|@|@|@|
O|©
| CHNo. [3] 9 [43/69] 2 [2 |
(4) Writes the immobilizer mode in the EEPROM.
* Clears the immobilizer code.
* Pressing the FNC key on the remote control unit calls the TV Area setup screen.
TV Format
Country
Hungary
TV Format | Country
SECAM-BIG | Greece
Canceling the Test Mode
Any of the reset, momentary power down, ACC OFF and POWER OFF operations causes the test mode to be carceled and
resets all settings to the initial default vaiues.