Download Print this page

Calimar CMARCIC40-1Y Installation And Operation Manual

Chlorination system replacement salt cell

Advertisement

Quick Links

CHLORINATION SYSTEM REPLACEMENT SALT CELL
INSTALLATION AND OPERATION MANUAL
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS

Advertisement

loading

Summary of Contents for Calimar CMARCIC40-1Y

  • Page 1 CHLORINATION SYSTEM REPLACEMENT SALT CELL INSTALLATION AND OPERATION MANUAL READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS...
  • Page 2 Thank you for your purchase of a CaliMar® replacement salt cell. The CaliMar® CMARCIC series salt cells are compatible with Pentair® IntelliChlor® saltwater chlorination systems. Compatible with CaliMar® Salt Cell Volume in Compatible with Pentair® Warranty Pentair® Salt Cell Part Numbers...
  • Page 3: Table Of Contents

    Contents Important Safety Instructions ............................. 1 Introduction ................................1 Water Chemistry ................................ 6 Installation ................................10 LED Light Instructions ............................... 12 Operation ................................. 13 Maintenance ................................14 Troubleshooting ............................... 17...
  • Page 4: Important Safety Instructions

    Important Safety Instructions Please disconnect all AC power supplies during installation. Do not let children use this product. To reduce the risk of personal injury, the power pack must be installed and wired to the load side of the clock or the load side of the relay. To reduce the risk of electric shock, the power pack must be grounded.
  • Page 5 Dual Voltage 115V-230V Power Center: The Power Center is a dual-voltage power supply, which means that there is no need for 115V/230V wiring. This power supply converts the AC current into the low-voltage DC current needed to generate chlorine gas. The power center contains transformers, fuses, cell connectors, AC current wiring configuration, and DC current output cables which are connected to the CMARCIC series cell.
  • Page 6: Water Chemistry

    Water Chemistry Note: Dry acid can cause a build-up of by-products that can damage the chlorinator cells. New Pool Water: Newly filled or refurbished pools may contain undesirable substances. Such undesirable substances may interfere with the CMARCIC series cell’s ability to properly chlorinate. Before turning on the CMARCIC cell, make sure the water has been tested and properly balanced by a professional pool.
  • Page 7 Ideal Water Chemistry Level Voltage input 230VAC/115VAC 7.2-7.8 50-300 for vinyl Calcium Hardness 220-320 for fiberglass 350-450 for plaster Total Alkalinity 60-180 ppm Ideal Salt Level 2600-4450 ppm Cyanuric Acid 30-50 ppm Chlorine 1-4 ppm How to test chlorine? It is recommended that chlorine test samples be collected and compared from two (2) locations in the pool. A higher level should be found at the pool return line.
  • Page 8 The formula for Si: SI = pH + CHF + AF + TF + TDSF. Cyanuric acid in the form of cyanurate ions contributes to the alkalinity. Therefore, the total alkalinity must be corrected. We subtract 1/3 of the cyanuric acid level from the reading obtained in the total alkalinity test. Total Alkalinity - 1/3 Cyanuric Acid = Corrected Alkalinity This correction can be considerable in established pools with high Cyanuric Acid levels;...
  • Page 9 Pounds and (Kg) Of Salt Needed For 3400 PPM...
  • Page 10: Installation

    Amount Of Stabilizer (Cyanuric Acid) Needed to Obtain 40 PPM in Pool (The Cyanuric Acid should be at 30-50 ppm) Installation Ensure that chlorine/bromine feeder is installed after cell. When CMARCIC is used with the in-floor cleaning system, it is suggested to use a separate return pipe for the cleaner to reduce the increased hydraulic stress on the CMARCIC series cell.
  • Page 11 Be sure to install CMARCIC after the filter and heater. The CMARCIC cell shall be at least three (3) feet from the outlet of the heater. If CMARCIC is installed on a combined swimming pool/spa system, please install it before the backflow valve of the swimming pool/spa (see the figure below).
  • Page 12: Led Light Instructions

    1. Before connecting the power cord to the power center, please make sure that the AC power supply is turned off. 2. Align the two (2) pins of the cell power cord connector with the socket on the top of the power supply. 3.
  • Page 13: Operation

    No Flow LED On: No water in the cell. Sanitize Output Setting: Press the button MIN and MAX, 10% for each setting. Operation IMPORTANT An external pool pump timer required. CMARCIC aims to provide enough chlorine to disinfect the pool water every day. If the pool pump runs continuously for 24 hours and CMARCIC runs at 100%, it will produce more chlorine than most swimming pools need (1-4 ppm).
  • Page 14: Maintenance

    According to the suggestion of APSP, the adjustment should be continued as needed, and the interval between each adjustment should be 24 hours until the free chlorine level in the pool water is stable at 1.0-4.0 ppm. Precautions: Don't fertilize your swimming pool. Fertilizer contains nitrate, which will lead to a high demand for chlorine.
  • Page 15 suggested that the APSP standard of salt pond should be at least 3000 to at most 5700-6000 ppm (including salt). Cleaning Blades Remove calcium buildup from the cell before acid cleaning: Use a garden hose on the spray setup and spray directly into the ends of the cell.
  • Page 16 Continue to check every two (2) months. However, due to possible changes in pool water chemistry and filtration, it is recommended that the cell be removed for inspection at least twice a year. Reconnect the CMARCIC cell communication cable plugs at the power center, then reconnect AC power to the CMARCIC cell power center.
  • Page 17: Troubleshooting

    Troubleshooting PROBLEM POSSIBLE CAUSE SUGGESTED ACTION Sanitizer Output percentage set too low or Increase Output Level. off at 0% Insufficient run time Increase run time to at least 1 hour per 10° ambient temp. Heavy pool use, inclement weather, organic Activate Super CL mode or chemically matter shock pool.
  • Page 18 Insufficient circulation Ensure operation of the pump, at least 25-30 GPM. Check water level, filter pressure, or for air or blockages in PVC plumbing. O-Ring improperly seated Ensure O-Rings are clean and in good condition. Water leak Threaded collars are cross-threaded. Inspect threads for damage, ensure that each screw goes back on without resistance.
  • Page 19 Should a defect in any item or part covered by the warranty become evident during the warranty's term, CaliMar® will at its sole discretion repair or replace such item or part. CaliMar® reserves the right to replace defective parts with new or refurbished parts. This warranty does not include the cost of labor or transportation charges for equipment or component parts to or from CaliMar®, or the removal, reinstallation, or any such costs incurred in...
  • Page 20 CaliMar® Pool Products USA, Inc. Manufacturers of Innovative & Quality Pool & Spa Products sales@calimarpool.com www.calimarpool.com...

This manual is also suitable for:

Cmarcic20-1yCmarcic60-1y