ELREHA VPR 5340 Operating Manual

ELREHA VPR 5340 Operating Manual

Compound control central

Advertisement

Available languages

Available languages

Quick Links

Product description / Application
• Compound control system for cooling plants
Capability for control of 3 Compounds or up to 3
Brine Chiller systems
Control of Compressors / VCondensers / Gascooler
and up to 128 networked Cold Storage Controllers
• Heatpump control is also covered
TFT-Display for display / operation of all plant data
• Cold Storage Controllers are included in
optimization functions
• Integrated error messaging system
• Integrated 12-Channel annual time switch
Communication by Ethernet, E-Mail, USB
Dear customer!
By purchasing a VPR 5340 control system, you have the
new generation of our Compound control system in
hands, which is equipped with modern functions.We
think it is mandantory to make yourself familiar with the
system prior to take it into operation, as the amount of
possible settings may be too much to be overseen at first
sight.
The present document is a short overview which just
covers the general operation and the required technical
data. More detailed info about the parameters and
control functions are provided in a separate
documentation.
If you have any questions, please do not hesitate to
contact us.
In this documentation you will find:
- General instructions for use of the device.
- The structure of the user interface and the screens
and menus.
- Connection diagram and safety instructions.
This document does not contain:
- Tables of all parameters and value ranges.
- Functional descriptions of the controlling
algorithms.
These additional info is covered by separate
documentation.
Please observe safety instructions !
Plase note that the descriptions herein are only valid for
units which are running the above mentioned software
version. The software version is noted on the screen
‚Configuration'.
VPR 5340 5321676-0000e03
Ihr ELREHA Team
How to configure and order a VPR 5340 central unit
When you are planning an application, you will know about the needed
ressources regarding Compressors, Condensation fans or Pumps, or
which messge input signals need to be served. The input and output
signals are assigned dynamically, depending on the configuration of
your application. Therefore you will not see at first glance, which I/O
modules will be needed and how to do the connections. These
information is served by the free Configuration tool VPR53Plan.
How to proceed:
- Get the VPR-Configuration tool VPR53Plan started on your PC. This
- Enter all the basic data of your application into the software: Amounts
- As an output you will get:
Accessories (not included with the central unit)
ELEKTRONISCHE REGELUNGEN GMBH
Operating manual
Compound Control central
Program is running on MS-Windows. You may request it from us or
directly download it from our homepage at "www.elreha.de" ==>
Download ==> Software.
of Compressors / Condenser fans, Error message processing,
Pressure transmitters, Temperature probes etc.
1. An overview of all the needed ressources of the VPR-System
2. A terminal listing, which can be used to set up the plant plans
3. A list of needed items,
which serves as the basis for your purchase order.
4. A parameter listing of the most important data
for starting up your application.
Expansion modules
BMO 3011 / BMO 3031
BMR 3001
BMA 3251/ BMA 3206
5321676-0000e03
2024-01-24 tkd/mr
VPR 5340
from Software Version S 03.05.00
Page 1 of 16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VPR 5340 and is the answer not in the manual?

Questions and answers

Summary of Contents for ELREHA VPR 5340

  • Page 1 • Communication by Ethernet, E-Mail, USB Dear customer! By purchasing a VPR 5340 control system, you have the new generation of our Compound control system in hands, which is equipped with modern functions.We think it is mandantory to make yourself familiar with the...
  • Page 2: Table Of Contents

    Date bus LINE 2 for Subcontrollers....(RS-485) Screw terminals, 2,5mm² Date bus ICOM für I/O-Busmodules....(RS-485) Screw terminals, 2,5mm² USB Connector..............(USB 2.0) A-type socket USB Connector............(USB 2.0) Micro B type socket Network Connector............(Ethernet 100 MBit) RJ-45 Memory card slot........Standard SD/MMC card slot (Push/Push) VPR 5340 5321676-0000e03 Page 2 of 16...
  • Page 3: Connection And Safety Instructions

    The entire operation is carried out via the large TFT display with the touch-sensitive 'touch screen' Basically, the contents are color-coded: Coloured display White font stands for descriptive texts and actual values that cannot be changed. Blue font is used for adjustable values, VPR 5340 5321676-0000e03 Page 3 of 16...
  • Page 4: Display And Control Elements

    On the right side of the screen, fields with directional arrows are displayed if necessary. These are only visible if the screen can be moved down or up to display more content. When the device is switched on, a start screen with ELREHA lettering appears, a gray bar shows the status Startup display...
  • Page 5: Programming Selection Parameters

    <--These four buttons are located at the bottom of the screen. Screen ‚Configuration‘ Configuration screen contains the categories shown here. In the following graphic, the parameter groups contained in each of them are named. VPR 5340 5321676-0000e03 Page 5 of 16...
  • Page 6: Language Selection

    Sub-Controller-Setpoints Like 1. + Programming of Subcontroller setpoints Setpoints Like 2. + Programming of Compound setpoints Configuration parametersLike 3. + Programming of Configuration parameters + Programming of PINs for Users with access levels 1-3 VPR 5340 5321676-0000e03 Page 6 of 16...
  • Page 7: User Logout

    Advanced error codes cannot be prioritized individually. I/O Busmodules In order to read in analog and digital signals and output control signals, the VPR 5340 uses I/O modules that are Usage of the inputs and outputs of connected to the VPR 5340 by a dedicated data bus.
  • Page 8: Bmr 3001

    If the settings have not been previously saved either internally, on a USB stick or on an SD card, they cannot be restored after executing the function! VPR 5340 5321676-0000e03 Page 8 of 16...
  • Page 9: Home-Screen

    Not assigned Subcontrollers All subcontrollers without a compound assignment are displayed on this page. Detailed Subcontroller display On all of these overview pages, selecting a controller symbol opens the detailed view of the respective subcontroller. VPR 5340 5321676-0000e03 Page 9 of 16...
  • Page 10: Contact Data Of Service Company

    The page with contact details is accessible via this. The address of a service company can be stored here. There are 6 lines of 40 characters each available. VPR 5340 5321676-0000e03 Page 10 of 16...
  • Page 11: Appendix: Overview Of Screens

    Appendix: Overview of On this page you will find the structure of the individual screen pages in an enlarged view. screens Detail image: Screen pages of the configuration and service parameters VPR 5340 5321676-0000e03 Page 11 of 16...
  • Page 12: Appendix: Errorcodes

    Kühlstellen- (KST) Warnung Adr.24 *265 V1, Kr.2 Verfl.lüfter 10 Si-kette Kühlstellen- (KST) Warnung Adr.25 *266 V1, Kr.2 Verfl.lüfter 11 Si-kette Kühlstellen- (KST) Ausfall Adr.00 Kühlstellen- (KST) Warnung Adr.26 *267 V1, Kr.2 Verfl.lüfter 12 Si-kette VPR 5340 5321676-0000e03 Page 12 of 16...
  • Page 13 Kühlstellen- (KST) Warng. Adr.30/Line2 Kühlstellen- (KST) Ausfall Adr.00/Line2 KST-Sicherheitsabsch. Verfldruck V3 Kühlstellen- (KST) Warng. Adr.31/Line2 Kühlstellen- (KST) Ausfall Adr.01/Line2 KST-Sicherheitsabsch. extern V3 Kühlstellen- (KST) Warng. Adr.32/Line2 Kühlstellen- (KST) Ausfall Adr.02/Line2 KST-Sicherheitsabsch. Saugdruck tief V1 VPR 5340 5321676-0000e03 Page 13 of 16...
  • Page 14 Def. Druckeingang 24 Abtaueinleitung KST Adr.24/Line1 Abtaueinleitung KST Adr.62/Line2 Def. Druckeingang 25 Abtaueinleitung KST Adr.25/Line1 Abtaueinleitung KST Adr.63 /Line2 Abtaueinleitung KST Adr.26/Line1 Abtaueinleitung KST Adr.27/Line1 Def. Temperatureingang 16 Abtaueinleitung KST Adr.28/Line1 Def. Temperatureingang 17 VPR 5340 5321676-0000e03 Page 14 of 16...
  • Page 15 Zuordnung x_26 FKurzF6 x_11 Intern SDR 3168 Sammlerdruckregler x_29 Untertemperatur x_16 FBruchF1 DatenInit x_30 Übertemperatur x_17 FBruchF2 Hardwarefehler x_31 LineAdresse x_18 FBruchF3 NetzEinReset x_32 ReglerEin x_19 FBruchF4 NetzAus x_33 ReglerAus x_20 FBruchF5 Parallelverd. VPR 5340 5321676-0000e03 Page 15 of 16...
  • Page 16 Die Konformitätserklärung ist unter folgender Adresse hinterlegt: The declaration of conformity is deposited at the following address: ELREHA Elektronische Regelungen GmbH Schwetzinger Str. 103 | 68766 Hockenheim Germany | Phone: +49 6205 2009-0 | E-Mail: sales@elreha.de HINWEIS NOTICE Diese Anleitung haben wir mit größter Sorgfalt und nach bestem Wissen erstellt. Änderungen This manual has been set up with care and our best knowledge.

Table of Contents