Guidelines that apply to Intelbras employees » Intelbras employees are subject to safe trading practices and data confidentiality under the terms of the company's work procedures. » It is imperative that the following rules are observed to ensure that statutory provisions relating to services (be they in-house services or remote administration and maintenance) are strictly followed.
Preparing for installation This document is applicable to the following Ethernet switches: Table 1 Switch series and models Switch series Model SC 3170-24G-4X SC 3170-48G-6X SC 3170 switch series SC 3170-24GP-4X SC 3170-48GP-6X Safety recommendations To avoid any equipment damage or bodily injury caused by improper use, read the following safety recommendations before installation.
Page 6
High temperature can accelerate the aging of insulation materials and significantly lower the reliability and lifespan of the switch. For the temperature and humidity requirements of the switch, see technical specifications in Intelbras SC 3170 Switch Series Hardware Information and Specifications. CAUTION: Ground the switch correctly and verify the grounding.
Item Requirements • Ground the switch, rack, independent power supplies, and lightning arresters separately. • You must ground optical fibers with reinforcing metal stiffener from outdoors on an optical distribution frame (ODF) or fiber splice enclosure. CAUTION: Do not run an Ethernet cable and power cord in parallel. Cable routing •...
Corrosive gas limit Corrosive gases can accelerate corrosion and aging of metal components. Make sure the corrosive gases do not exceed the concentration limits as shown in Table Table 4 Corrosive gas concentration limits Average concentration (mg/m Maximum concentration (mg/m 0.01 0.03 0.05...
Category Definition Example controlled. environment with air conditioners, outdoor air • conditioner cabinets, and heat Completely enclosed or shielded exchanger cabinets. indoor environments. • Simple equipment rooms, ordinary Indoor environments where houses, garages, corridors, and temperature and humidity are partially A2: indoor partially controlled.
Item Requirements • If the external power supply system provides an AC power outlet, prepare a country-specific AC power cord yourself. Make sure the PE wire of the AC power supply is grounded reliably. Power receptacle and • If the external power supply system provides a DC distribution box, prepare cables DC power cords yourself.
Page 11
Code Description Quantity Applicable device models Grounding screw 1, provided All models 1, provided for AC power cord the switch with a built-in power supply All models 1, provided with removable power supplies DB9-to-RJ45 console cable 04042967 1, optional All models USB-to-RJ45 console cable 0404A1EE 1, optional...
CAUTION: Keep the tamper-proof seal on a mounting screw on the chassis cover intact, and if you want to open the chassis, contact Intelbras for permission. Otherwise, Intelbras shall not be liable for any consequence. Figure 1 Hardware installation flow...
Installing the switch in a 19-inch rack Installation methods Table 9 Installation methods Applicable switch Installation Requirements and Installation procedure models method guidelines Select an installation position for SC 3170-24G-4X the front mounting brackets as required: near the power supply SC 3170-48G-6X "Rack-mounting the Using front...
Page 14
Attach the front mounting bracket to the other side of the chassis in the same way. Figure 3 Attaching the front mounting brackets to the port-side mounting position Figure 4 Attaching the front mounting brackets to the power supply-side mounting position Mounting the switch in the rack This task requires two people.
Page 15
Figure 5 Mounting the switch in the rack (port-side mounting position for the front mounting brackets) Figure 6 Mounting the switch in the rack (power supply-side mounting position for the front mounting brackets)
Mounting the switch on a workbench IMPORTANT: • Reserve a minimum clearance of 10 cm (3.9 in) around the chassis for heat dissipation. • Do not place heavy objects on the switch. To mount the switch on a workbench: Verify that the workbench is sturdy and reliably grounded. Place the switch with bottom up, and clean the round holes in the chassis bottom with dry cloth.
Figure 7 Connecting the grounding cable to the chassis (1) Grounding screw (2) Ring terminal (3) Grounding sign (4) Grounding hole (5) Grounding cable Connecting the grounding cable to a grounding strip Use needle-nose pliers to bend the bare metal part to the shape as shown in Figure 8.
Figure 9 Grounding the switch by burying the grounding conductor into the earth ground (1) Grounding screw (2) Grounding cable (3) Earth (4) Welding point (5) Grounding conductor (6) Chassis rear panel Verifying the connection after grounding the switch • If you ground the switch by using a grounding strip, perform the following tasks: a.
Power supply model Installation method PSR920-54A-B PSR1600-54A-B Installing/removing a power supply (1) This section applies to the CA-70A12, PSR75-12A, and PSR150-D1 power supplies, which use a similar installation/removal procedure. A PSR75-12A power supply is used as an example. Installing a power supply Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
Figure 11 Installing a power supply Removing a power supply Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded. Disconnect the power cord. Loosen the captive screws on the power supply with a Phillips screwdriver until they are completely disengaged.
Page 21
Remove the filler panel, if any, from the target power supply slot. Put your forefinger into the hole in the filler panel and then pull the filler panel out of the slot gently. Keep the removed filler panel secure for future use. Figure 13 Removing the filler panel from the target power supply slot Unpack the power supply.
Page 22
Figure 15 Installation completed NOTE: The PSR1110-56A power supply, including its handle, adds 64 mm (2.52 in) to chassis depth. Removing a power supply Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded. Disconnect the power cord.
Connecting the power cord CAUTION: • CA-70A12 and PSR75-12A power supplies use C13 power cords, and PSR180-56A, PSR360-56A, PSR720-56A, PSR1110-56A, PSR600-54A-B, PSR920-54A-B, and PSR1600-54A-B power supplies use C15 power cords (used in high temperature). Do not mix power cords for different power supplies. •...
Figure 17 Connecting the power cord for a built-in power supply(1) Figure 18 Connecting the power cord for a built-in power supply(2) Connecting the power cord for a CA-70A12 or PSR75-12A power supply The power cord connection procedure is similar for the CA-70A12 and PSR75-12A power supplies. The following procedure connects the power cord for a PSR75-12A power supply.
• To use a –48 VDC power source to supply power to the power supply, use the DC power cord supplied with the power supply. • To use an Intelbras RPS (–54 VDC) to supply power to the power supply, use a compatible RPS power cord to connect the RPS to the power supply.
Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded. Unpack the power cord, correctly orient the plug at one end of the cable with the power receptacle on the power supply, and insert the plug into the power receptacle (see callout 1 in Figure 21).
Figure 22 Connecting the power cord for a PSR360-56A power supply Verifying the installation Before powering on the switch, verify the following items: • There is enough space around the switch for heat dissipation. • The rack or workbench on which the switch is mounted is stable. •...
Accessing the switch for the first time Connecting the switch to a configuration terminal The SC 3170 series switches each provide a serial console for connecting to a configuration terminal. Figure 23, the switch is connected to a configuration terminal (PC as an example) from the serial console port.
A DB9-to-RJ45 console cable is an 8-core shielded cable, with a crimped RJ-45 connector at one end for connecting to the serial console port of the switch, and a DB-9 female connector at the other end for connecting to the serial port on the console terminal. Figure 24 DB9-to-RJ45 console cable A side Pin 9...
Starting the switch Pre-start checklist Before powering on the switch, verify the following items: • The power cord is correctly connected. • The input power voltage is as required by the switch. • The console cable is correctly connected. • The PC has started, and the terminal parameters have been correctly configured.
Setting up an IRF fabric (Stacking) You can use Intelbras IRF technology to connect and virtualize SC 3170 switches into a large virtual switch called an "IRF fabric" for flattened network topology, and high availability, scalability, and manageability. A SC 3170 switch can set up an IRF fabric only with switches from the same switch series.
Step Description • Identifying physical IRF ports on the member switches • Planning the cabling scheme "Installing the switch in a 19-inch rack" or "Mounting the switch Install IRF member switches on a workbench." Connect grounding cables and "Grounding the switch"...
Planning IRF topology and connections You can create an IRF fabric in daisy chain topology or more reliable ring topology. In ring topology, the failure of one IRF link does not cause the IRF fabric to split as in daisy chain topology. Instead, the IRF fabric changes to a daisy chain topology without interrupting network services.
SFP port—GE SFP fiber transceiver module and optical fiber, GE SFP copper transceiver module and twisted pair cable or GE SFP cable. For the available transceiver models and cables, see ports in Intelbras SC 3170 Switch Series Hardware Information and Specifications. •...
Page 35
The following subsections describe several Intelbras recommended IRF connection schemes by using SFP+ cables and SFP+ transceiver modules and fibers. All these schemes use a ring topology. IMPORTANT: In these schemes, all physical IRF ports are located on the same side. If physical IRF ports are on different sides, you must measure the distance between them to select an appropriate cable.
Connecting the IRF member switches in a ToR solution You can install IRF member switches in different racks side by side to deploy a top of rack (ToR) solution. Figure 30 ToR cabling Configuring basic IRF settings After you install the IRF member switches, power on the switches, and log in to each IRF member switch to configure their member IDs, member priorities, and IRF port bindings.
Page 37
Table 15 Displaying and maintaining IRF configuration and running status Task Command display irf Display information about the IRF fabric. Display all members’ IRF configurations that take display irf configuration effect at a reboot. display irf topology Display IRF fabric topology information. NOTE: To avoid IP address collision and network problems, configure a minimum of one multi-active detection (MAD) mechanism to detect the presence of multiple identical IRF fabrics and handle...
Symptom The system status LED on the switch indicates a fan tray failure. Solution When a fan tray issue occurs, contact Intelbras Support. Configuration terminal display issues If the configuration environment setup is correct, the configuration terminal displays booting information when the switch is powered on. If the setup is incorrect, the configuration terminal displays nothing or garbled text.
Page 39
Verify that the console cable is correctly connected. Verify that the console cable does not have any issues and the terminal settings are correct. If the issue persists, contact Intelbras Support. Garbled display Symptom The display on the configuration terminal is garbled.
Page 40
Consumer makes a regular backup copy of the data contained in the product. 7. Intelbras is not responsible for the installation of this product, nor for any attempts at fraud and/or sabotage in its products. Keep the software and applications used up to date, if applicable, as well as the necessary network protections to protect against intrusions (hackers).