T Series Hi-Lo Units With Double Gear Pump
READ ALL INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR
MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY
AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
WARNING: THIS INSTRUCTION MANUAL IS INTENDED FOR USE BY QUALIFIED INDIVIDUALS WITH A
WORKING KNOWLEDGE OF HYDRAULIC AND ELECTRICAL PRINCIPLES. PROFESSIONAL INSTALLATION IS
RECOMMENDED.

Advertisement

loading
Need help?

Need help?

Do you have a question about the T Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Bucher Hydraulics T Series

  • Page 1 T Series Hi-Lo Units With Double Gear Pump READ ALL INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 an unloader if the directional control valves are Description to have P ports blocked. Hi-Lo hydraulic units are typically used when the application requires relatively high flow at low The power units can be coupled via suitable pressure and relatively low flow at high pressure. hydraulic lines to a wide variety of hydraulically Typical applications include bearing presses and Proper circuit design must...
  • Page 3 Figure 1 – T92E405C91F4-01 Figure 2 – T92E405C91F1-01 Dimensions Figure 3 – T92E405C91F4-01 Hydraulic schematic P a g e...
  • Page 4 All the power units are packaged fully assembled 3. Make sure that the work area and the and tested. Customer is responsible to fill the hydraulic components are clean and free reservoir with proper level of a quality hydraulic from dirt, lint, etc fluid suitable for use in the intended 4.
  • Page 5 NOTE: Voltage drop increases with the length of WARNING power cord. Larger wire diameter may be REPLACE OR REPAIR DAMAGED OR WORN required. POWER CORDS IMMEDIATELY. 3. Motor nameplate voltage must be available DO NOT OPERATE UNIT WITHOUT PROPER at the motor when it is operating under load. GROUNDING.
  • Page 6: Troubleshooting Chart

    3. Bleed air from systems 4. Oil temperature is too high 4. Let oil cool well below 130°F Recommended Operating Conditions for T Series Hi-Lo Units with Double Gear Pump Oil Temperature Range: ……………………………………….………………………………………10°F -170°F Recommended Operating Temperature: …………………….………………………………..50°F -130°F Oil Viscosity: Optimum: …………………………………………………………………………..….100 - 350 SUS...
  • Page 7 HYDRAULIC POWER UNIT PERFORMANCE MODEL Reservoir Nominal Max. Voltage Phase Hz Rated Capacity Flow Pressure Motor Current T92E405C91F1-01 30GAL.(20 11/2.8 3200 PSI 230/460 60 12.4/6.18 USABLE) P a g e...
  • Page 8 P a g e...
  • Page 9 ITEM NO. PART NO. DESCRIPTION 51020646310 Reservoir, 30 gal, 22gal usable 51020527870 Nut, Muti-thread U, 5/16UNC-18 500205901075 Plug, Steel, 3/4" NPT 500203701436 Gauge, 5" Sight-Temperature 51020830698 Tube,return,1-1/4"NPTX19"long 51020630185 Pump,18/6cc/rev,cw,SAE A 51020330284 Adapter, 8JICM to 10SAEM 51020330375 90 deg swivel JIC elbow 51020441037 Hose ass'y, 1/2"JICF to #10 ORBM 500203201083...

This manual is also suitable for:

T92e405c91f4-01T92e405c91f1-01