Adjustment Method
White Balance Adjustment
Instrument Name
1.
Remote controller
2.
LCD WB meter (Minolta CS-1000A equivalent)
3.
Comunication jig
4.
Computer for external control
White Balance adjustment
1.
Procedure basically performs checking using the production software and
make automatic adjustment using external computer.
2.
It adjusts in the mode of : Colour balance Cool
WHITE
GRAY
Procedure
Viewing Mode Dynamic
Normal
x: 0.270 ± 0.010
y: 0.276 ± 0.010
Normal
x: 0.270 ± 0.010
y: 0.278 ± 0.010
Connect to
16
Remarks
Correlation can be also taken by
CA-210 or equivalent
Remarks
Let the panel standfor more than 3
hours at more than 20 °C.
Basically perform adjustment in the
ambient environment of room
temperature more than 20 °C.
The aging time is more than 20 min
at above room temperature.
100% WHITE