Stereo Input; Led Power - Kenwood RX-28 Service Manual

Table of Contents

Advertisement

RX-28
CIRCUIT DESCRIPTION
Name
Description
Processing
BUSY
Serial "BUSY"
DATA
Serial "DATA"
UNUSED
GND
sc
Communication clock output
PU (+5V)
so
Communication data output
PU (+5V)
Sl
Communmication data input
PU (+5V)
S__REQ
Slave communication request
PD (GND)
S__RDY
Slave communication authorization
PD (GND)
M-REQ
Master communicatioin request
PD (GND)
PROTECT
Protection input
PD (GND)
TUNER MUTE
Tuner mute
PD (GND)
PLL_ST
PLL strobe
PD (GND)
PLL_CK
PLL clock
PD (GND)
PLL_DT
PLL data
PD (GND)
IF_IN
IF count input terminal
,
PD (GND)
SD
SD input
PD (GND)
STEREO
STEREO input
PD (GND)
UNUSED
PD (GND)
POWER
LED POWER
UNUSED
Cc
—|-|-|-|ololojoj—jo/—-|—|-jo;0
O10
BACKUP
Backup input
REMOCON
Remote controller input
a
Key return 0
Key return 2
Key return 3
Key return 4
Key return 5
Key return 6
KR4
KR5
KR6
UNUSED
| vss
| GND
XTAL
aif
Oscillator terminal (4.19 MHz XTAL)
UNUSED
EXTAL
Oscillator terminal (4.19 MHz XTAL)
VREF
Voltage detect reference voltage terminal (unused)
VFDP
FL load power supply terminal (— 30V)
| RKSO
eee
section key scan 0
| RKS1
Receiver section key scan 1
| RKS2
Receiver section key scan 2
RKS3
Receiver section key scan 3
12

Advertisement

Table of Contents
loading