User-Service Manual
Joerns
Bed Frames
®
UltraCare
XT
®
To avoid injury, read user's manual before using.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UltraCare XT and is the answer not in the manual?

Questions and answers

Summary of Contents for Joerns UltraCare XT

  • Page 1 User-Service Manual Joerns Bed Frames ® UltraCare ® To avoid injury, read user’s manual before using.
  • Page 2: Important Precautions

    6 inches deep. Length should match mattress support by Joerns Healthcare on any Joerns bed. Use of unapproved platform. Use of an improperly fitted mattress could result replacement parts may result in injury or death.
  • Page 3 Caution: In the absence of line voltage, all bed adjustments Joerns assist devices are designed to be used with specific can be achieved via an externally available backup battery Joerns bed frames. Once mounted on the appropriate bed (Joerns P/N N111).
  • Page 4: Table Of Contents

    Joerns Healthcare, national healthcare organizations, That is why Joerns offers a wide array of compliance resident advocacy groups, and other federal agencies options. We assist customers in selecting compliant formed the Hospital Bed Safety Workgroup (HBSW).
  • Page 5: Features And Specifications

    Type B Applied Parts, user controls, mattress, Base Bed ............30.00" support platform Equipped with UltraLock(s) ......30.60" Protective Earth (ground) Safe Working Load .......... 650 lbs. Maximum Patient Weight ......... 600 lbs. Pinch Point ©2023 Joerns Healthcare • 6110445 RevA • 000547...
  • Page 6: Assembly

    3. Tap into place with a rubber mallet or press firmly (Figure 5). with the sole of your shoe until it locks into place as shown (Figure 5). ©2023 Joerns Healthcare • 6110445 RevA • 000547...
  • Page 7 ® equipment. There are two sockets at head end of bed and two at foot end (Figure 7). The IV sockets are compatable with Joerns IV poles and most ½" IV poles. Installation Of Staff Control Panel (Optional) (Figure 8) 1.
  • Page 8: Operation

    AutoTransfer Height: Press and hold to level the bed, flatten the head and knee, and lower to a transfer height. To change to a patient-specific transfer height, use the programmable AutoTransfer Height function on staff control. ©2023 Joerns Healthcare • 6110445 RevA • 000547...
  • Page 9 Change lockout BUTTON (OR status in combination SAFELIGHT with function button ACCESSORY, INSTALLED) BACK SECTION: AUTOTRANSFER HEIGHT: Lower Raise / lower back back / knee to flat. Place bed at low height ©2023 Joerns Healthcare • 6110445 RevA • 000547...
  • Page 10 ® height functionality to the UltraCare XT bed frame. ® The UltraCare XT bed can be configured with a single Figure 16 UltraLock at the foot or dual UltraLocks at the head and foot. • When the UltraCare XT is equipped with a single UltraLock, the foot end has swivel casters when the UltraLock is engaged and rollers at the head.
  • Page 11: Servicing

    Warning: Possible High Temperature. Prior to servicing any electrical component ensure the component has cooled to room temperature. ©2023 Joerns Healthcare • 6110445 RevA • 000547...
  • Page 12 1. Raise the bed so that there is about 27 inches of clearance between the floor and the mattress support platform of bed. 2. Unplug the power cable from the outlet. Figure 25 Figure 26 ©2023 Joerns Healthcare • 6110445 RevA • 000547...
  • Page 13: Troubleshooting

    3. If these steps fail to resolve the problem, call Technical Support at 800-826-0270 articulation Note: Electrical damage can occur if a non-approved pendant is connected to the electrical system. ©2023 Joerns Healthcare • 6110445 RevA • 000547...
  • Page 14: Maintenance

    5. Make sure each inspection includes the underside Do not submerge pendant in liquid. of the bed frame and mattress support platform. 2. Your Joerns bed features durable, baked-on epoxy 6. Visually inspect the bed frame and accessories finish that is easily cleaned with mild solution of for any cracking, bending, or hole enlargement.
  • Page 15: Accessories

    Bar and the floor is required when the bed is in its lowest position. Failure to do so could damage the floor and/or cause the bed to become unstable, resulting in injury or death. ©2023 Joerns Healthcare • 6110445 RevA • 000547...
  • Page 16 5. Adjustment and use of a Trapeze should be in accordance with instructions from a healthcare professional (doctor or therapist). 6. Do not exceed the maximum load condition listed Figure 29 on installation instructions. ©2023 Joerns Healthcare • 6110445 RevA • 000547...
  • Page 17 Do not allow items suspended from holder to rest on the floor, particularly when bed is in its lowest position. Otherwise, a safety condition may occur or the function of attached items may be impacted. ©2023 Joerns Healthcare • 6110445 RevA • 000547...
  • Page 18 UltraCare XT bed, particularly when it is lowered ® on to its casters. Note: The UltraCare XT bed is not designed for use as resident/patient transport devices. Prior to use, please read important warnings relaeted to Bed Transport Bar and follow all instructions below.
  • Page 19 Manufacturer’s Declaration –Electromagnetic Emissions The Joerns UCXT bed is intended for use in the electromagnetic environment (for professional healthcare) specified below. The customer or the user of the Joerns UCXT bed should assure that it is used in such an environment. Emissions test...
  • Page 20 Guidance and Manufacturer’s Declaration - Electromagnetic Immunity: The Joerns UCXT bed is intended for use in the electromagnetic environment (for professional healthcare) specified below. The customer or the user of the Joerns UCXT bed should assure that it is used in such an environment. Immunity Test...
  • Page 21 Guidance and Manufacturer’s Declaration – Electromagnetic Immunity The Joerns UCXT bed is intended for use in the electromagnetic environment (for professional healthcare) specified below. The customer or the user of the Joerns UCXT bed should assure that it is used in such and environment. Immunity test...
  • Page 22: Warranty