Download Print this page
Quantify qBlind PN01-A008 Series Installation Manual

Quantify qBlind PN01-A008 Series Installation Manual

Blind controller

Advertisement

Quick Links

Specifications
Operating Voltage AC
220-240V
Frequency
50Hz
Max. Total Capacity
275W
Wiring Configuration
Standard wiring
Minimum Load
Standard wiring
Output Channels
L1, L2
Over-current Protection
Yes
Current Monitoring
Yes
Operating Temperature
0°C to 40°C
Operating Humidity Range
10 to 85% RH
Mounting Cavity
80mm
Mounting Centres
84mm
IP rating
IP20
Safety Compliance/
IEC 60669-1
EMC Compliance
Warranty
GENERAL WARRANTY ON PRODUCTS
LIMITED WARRANTY
Quantify offers a warranty of 24 months (Warranty Term) from the date of delivery of the Quantify products for all defects in materials or workmanship for any
products supplied to the Client. Where a product supplied to the Client is defective within the Warranty Term, Quantify will either repair or replace those products
at its discretion. Refurbished parts may be used to repair the Products. Replacement of the Product or a part does not extend or restart the Warranty Term. If
a Product presented for repair is capable of retaining user-generated data, the Reseller acknowledges that repair of the Product may result in loss of the data.
Quantify may offer different delivery methods for warranty service, including, but not limited to, parts and product dispatches, mail-in service and onsite/in-home
service or as otherwise agreed between the Client and Quantify in writing. Quantify will cover any costs to get the repaired/tested/replaced Products back to the
Client. Any Products being sent in for warranty should be sent with all parts unless otherwise advised by one of Quantify's staff.
GENERAL EXCLUSIONS AND LIMITATIONS
The Warranty will not apply:
a. to a Product which has not been installed, operated, maintained or used in accordance with the manufacturer's instructions or specifications provided with
the Product;
b. to a Product where the factory-applied serial number has been altered or removed;
c. to a Product where the Product is, or has been damaged, has malfunctioned or failed due to alterations, accident, misuse, abuse, fire, liquid spillage, mis-
adjustment of customer controls, used on an incorrect voltage, power surges and dips, thunderstorm activity, acts of God, voltage supply problems, tampering or
unauthorised repairs by any persons other than by Quantify, the operation of a computer virus of any kind, exposure to abnormally corrosive conditions or entry by
any insect, vermin or foreign object in the Product, normal wear and tear, or use of parts and components not supplied or intended for use with Quantify's Products;
d. to third-party products or software that are bundled or provided with the Services; and
e. in relation to results to be obtained from the products or Software.
Full terms and conditions including Warranty Terms can be found on Quantify's website.
Technical Specifications for products with future release dates are subject to change and should not be relied upon.
Quantify Technology Pty Ltd
Suites 2 & 3, 6 Brodie Hall Drive, Technology Park, Bentley, WA, 6102
+61 (8) 6254 0200
info@quantifytechnology.com
www.quantifytechnology.com
Dedicated neutral
5W
Each channel 1x2A fuse and 1x115°C thermal fuse
Accurate to 5% at 25°C
54mm
45mm
IEC 60669-2-1 (Relevant sections)
Product Description
The Quantify Blind Controller works with standard AC cabling techniques and can control two-pole, mains powered blind motors. All
electrical, policy and advanced living experience settings are fully configurable using the Quantify software.
Safety Information
DANGER: Electrical Shock Hazard. The supply circuit must be turned off, locked and tagged before installing the qBlind, or
working on loads connected to a qBlind. Voltage isolation is not provided by the qDevice. Hazardous voltages exist at terminals L1 to L2,
even if the device is in "off" state.
WARNING: Do Not Megger Test. Megger testing will damage the Blind Controller and will void warranty.
Compatible Load Types
Load Type
Max. load per channel
Blind motor
275W
IMPORTANT: Don't exceed 275W total load on the device. Overloading may result in it automatically switching off one or more loads.
IMPORTANT: Don't connect loads on different phases to the same device.
Incompatible Load Types
IMPORTANT: There should not be another switch between the device and the load.
This device is protected with both a thermal fuse and load fuse on each channel. Overloading the device on any channel will render the
channel inoperable and, in instances of severe overload, may render the entire device inoperable.
Loads with a high start-up current (inrush) should be avoided and will cause permanent damage to the device.
4 of 4
Version 1.0 • Data correct as of 1-7-2019. Refer to technical bulletins at www.quantifytechnology.com/tech-bulletins
Quantify qBlind
Blind Controller
PN01-A008-xx
INSTALLATION GUIDE
Notes
1 of 4

Advertisement

loading

Summary of Contents for Quantify qBlind PN01-A008 Series

  • Page 1 Quantify, the operation of a computer virus of any kind, exposure to abnormally corrosive conditions or entry by any insect, vermin or foreign object in the Product, normal wear and tear, or use of parts and components not supplied or intended for use with Quantify’s Products;...
  • Page 2 Living Experience configuration. IMPORTANT: Use only Quantify Technology Feature Cards, inserted with arrows in the Living Experiences include single service control, grouped services and scenes. The system can be correct alignment.