TABLE OF CONTENTS Safety Precautions Points For Attention iii. Product Overview Operation Instruction Wi-Fi Setup Drainage Instruction vii. Cleaning And Maintenance viii. Troubleshooting Warranty Information...
1. SAFETY PRECAUTIONS This page records the main topics of safety precautions to prevent personal injury or property loss of users and others. Please read them carefully and observe the precautions recorded here. Do not operate this machine with damp hands, nor rinse the dehumidifier directly with water or place it close to a water source.
Page 4
Never insert fingers or any objects into the air outlet. Children should be specifically warned about these dangers. During transport and storage, keep the unit upright to maintain the correct position of the compressor. Supervise children to prevent them from playing with the appliance.
Page 5
Contact an authorised service technician to repair or maintain this unit. Do not pull, deform. Or modify the power supply cable or immerse it in water. Pulling or misusing cable can damage the unit and cause electrical shock. Compliance with national gas regulations shall be observed. Keep ventilation openings clear of obstruction.
Page 6
Notes: Don’t hesitate to contact the dealer or a designated repair shop if any parts are damaged. In case of any damage, please turn off the air switch, disconnect the power supply, and contact the dealer or a designated repair shop. Firmly ground the power supply cable.
Page 7
Risk of Fire or Explosion. This unit contains flammable refrigerant additional safety precautions must be followed. • When handling. Installing • Do not use means to and operating the appliance. accelerate the defrosting Care should be taken to avoid process or to clean other than damaging the refrigerant those recommended by the tubing.
Page 8
Transportation of Equipment Employing Flammable Refrigerants Take note of any additional transportation regulations that may exist concerning equipment containing flammable refrigerants. The respective transport regulations will specify the maximum quantity of equipment, or the configuration of the equipment that can be transported together.
2. POINTS FOR ATTENTION Ensure the machine is placed on flat, sturdy ground. Maintain a gap of over 50cm (20 inches) between the wall and machine for optimal heat dissipation. Avoid submerging the machine in water or placing it near a water source.
Page 10
If using a power strip or other bases to power on the machine, ensure these devices comply with national safety regulations. If this machine is accidentally tilted, dumped, or has undergone long-distance transportation, allow it to stand upright for 4 hours before starting up.
Page 12
Specification: Region Europe Model TAURUS-RCS25(Y)-N7-1 Voltage 220V-240V 50Hz Power 320W Refrigerant R290/80g Daily Dehumidification 25L/D (30 C 80%RH) Capacity Effective Area 20-50m² Water Tank 5.5L Capacity Noise Decibel ≤45dB Timing Custom 0-24h Product Weight 13.8kg Product Dimension 366×220×613mm...
4. OPERATION INSTRUCTION Control Panel Left and Right Adjustment keys Anion Mode Key Comfort Mode Key Humidistat Key Timer Key Fan Speed Mode Key Power Key Power Key Description Power Key Press the power key once to turn it ON or OFF. The compressor is equipped with a self-protection feature that introduces a 3-minute delay if the machine is turned off and then on again within a 3-minute interval.
Page 14
Fan Speed Mode Key Use this key to select different levels of fans speed. The fan speed can be adjusted under each humidistat setting. Note: This key also serves as the Child Lock switch. Press and hold it for 3 seconds to activate or shut down the Child Lock. The corresponding indicator light will illuminate accordingly.
Page 15
Humidistat Key When you press this key, the corresponding status indicator and humidity symbol ‘%’ will illuminate. At the same time, the Left and Right Adjustment keys will light up and flash. This signals that you can set your desired target humidity using these adjustment keys.
Page 16
Indicator Light The two-digit code tube is a white light highlight field; Its display functions are as follows: The current measured ambient relative humidity states are displayed as follows. • In the startup state, the humidity can be displayed directly. •...
5. WIFI SETUP Installation and Setup of the “Smart Life” App Step 1: Download the “Smart Life” App Utilise your mobile phone’s camera to scan the QR code provided below, this will guide you to download the “Smart Life” app. Alternatively, you can manually find and download the app by typing “Smart Life”...
Page 18
Step 5: Manual Addition Select Device Type: In the app, choose the device type that matches your product. Use the sidebar to navigate through product categories, e.g., Small Home Appliances > Dehumidifier (Wi-Fi). Pairing Mode: Ensure the machine is on. Then press and hold the Timer button for about 5 seconds until you hear a beep.
6. DRAINAG INSTRUCTIONS Water Tank Drainage When the Full Tank alarm goes off, the indicator light is on, and the water quantity can be viewed through the tank window; Gently pull out the tank by hooking the buckle at the bottom. You can carry the tank (there is a built-in handle in the tank) to the drainage area, then lift the drainage lid at the corner of the tank lid and slowly tilt the tank to empty the water.
7. CLEANING AND MAINTENANCE Note: Before cleaning and maintaining the machine, please turn off the device and unplug the power plug in case of an electric shock. Before cleaning or maintaining the machine in any mode, the device must be shut down, the power plug must be unplugged, and water cannot be sprinkled on the machine;...
8. TROUBLESHOOTING Shutdown Before Maintenance: Always turn off the machine and unplug the power cord before cleaning or performing any maintenance. Avoid Water Exposure: Do not sprinkle water on the machine. Cleaning the Casing: Use a soft, damp cloth for cleaning. Avoid using chemical solvents such as benzene, alcohol, or gasoline as they can damage or deform the casing.
Page 22
Fault Fault Product Status Solution Description Diagnosis The touch control panel is functional. Code E1 in slow Temperature The machine is still flash sensor on the in operation and will Power off and on again. coil or associated work in the following circuit cycle: dehumidify for 30 minutes...
Page 23
Important Operational Notes Always ensure that the air inlet and outlet of the machine is unobstructed during operation. This is crucial for maintaining efficient airflow and preventing overheating or malfunction. If the machine displays any unknown error codes, first attempt to resolve the issue by powering off and then powering on the machine.
9. WARRANTY All Senelux products are covered from the original purchase date by a standard 2-year warranty. To register your warranty, please visit www. senelux.co.uk. If, in the unlikely event that your product has any manufacturing defect, please get in touch with our customer service team at support@senelux.co.uk.
Page 25
Senelux Ltd Unit 5-6 105 Boundary Street Liverpool L5 9YJ United Kingdom Email – info@senelux.co.uk Website – www.senelux.co.uk Be sure to tag us in your photos on social media using #seneluxathome to be featured @senelux.official @Senelux Thank you very much for using our products.
Need help?
Do you have a question about the Taurus and is the answer not in the manual?