Summary of Contents for Quantifi Photonics LASER 1100 Series
Page 1
LASER 1100 SERIES Tunable Laser Source PXIE USER MANUAL quantifiphotonics.com...
Page 2
Information provided by Quantifi Photonics is believed to be accurate and reliable. However, no responsibility is assumed by Quantifi Photonics for its use nor for any infringements of patents or other rights of third parties that may result from its use. No license is granted by implication or otherwise under any patent rights of Quantifi Photonics.
7.3 Select a module to work with 7.4 Set values 7.5 SET values and ACTUAL values 7.6 Manage CohesionUI settings 7.7 Synchronize and reinitialize CohesionUI 7.8 SCPI CohesionUI Command Console 3 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Page 4
9.5 Command summary 9.5.1 Common commands 9.5.2 Slot commands 9.5.3 Configuration commands 9.6 Command descriptions 9.6.1 Common commands 9.6.2 Slot commands 9.6.3 Configuration Commands 4 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Page 5
14.1 Contacting the Technical Support Group 14.2 Transportation 15 Warranty Information 15.1 General information 15.2 Liability 15.3 Exclusions 15.4 Certification 15.5 Service and repairs 5 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Controlling your LASER with CohesionUI SCPI commands: Controlling your LASER with SCPI commands Programming examples and applications Managing your LASER Cohesion Manager Cohesion Firmware Updater 6 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or component damage. Do not proceed unless the required conditions are met and understood. NOTE Indicates relevant information that requires your attention. 7 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Do not install or terminate fibers while the light source is active. Turn the Quantifi Photonics product OFF before inspecting the end face(s) of the product, or any optical patch cords connected to it. Never look directly into a live fiber; ensure that your eyes are protected at all times.
Store the unused product in the original protective electrostatic packaging that it was shipped in. Use a wrist strap and grounding table mat when unpacking or handling the product. 9 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
4 Introducing the LASER 1100 Series The Laser 1100 Series is a Continuous Wave (CW) laser source offering high power 850 nm output into multimode fiber with stable output power operation. The Laser 1100 Series will either be a single, or double slot configuration.
During startup: Indicates the initialization of the LASER module. flashing red After startup, if flashing persists for more than 15 seconds: Indicates an error. 12 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Ensure that the chassis being used supports PXIe (or contains PXI-hybrid compatible slots). If you are unsure if your chassis is compatible with your Quantifi Photonics product, please contact Quantifi Photonics Customer Support. Make sure to follow these instructions when installing or removing a Quantifi Photonics module from a PXIe chassis. CAUTION The product is sensitive to electrostatic discharge (ESD).
Push module into slot until you feel Engage the fastening clip. Secure all Power the chassis ON. resistance from the backplane connection. fastening screws. 14 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Use the fastening clip to pull. Do NOT pull on the connectors. Store the module in its antistatic bag. Power ON the chassis. 15 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
6 Installing software The Cohesion Installer software package enables communication between the PXIe controller and Quantifi Photonics modules installed in a chassis. The Cohesion Installer contains all required drivers and software: CohesionDriver Driver Service for Quantifi Photonics PXIe modules CohesionSCPI...
1. We recommended that you save your work and close open programs before installing Cohesion Installer. 2. Locate and run CohesionInstaller-<version_number>.exe from the provided USB media device (or download it from the Quantifi Photonics website) and follow the on-screen installation prompts.
Page 18
7. On startup after rebooting the system a User Account Control prompt might be displayed. Click Yes to allow running of the Cohesion Firmware Updater Utility and proceed with the application. 18 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
VXI11 compliant SCPI interface for TCP communication with the installed Quantifi Photonics modules CohesionUI optional web service providing a graphical interface for simplified operation of installed Quantifi Photonics modules To open Cohesion Manager: Search for Cohesion Manager in the Windows Start Menu.
Cohesion Manager application. It is a single-window summary application that enables you to: view the current firmware status of all Quantifi Photonics PXIe modules installed in the chassis. update firmware to a new version if available.
7 CohesionUI - Overview CohesionUI is a web-based graphical interface that you can use to work with your Quantifi Photonics products. CohesionUI is part of the Cohesion Installer software package. For details on Cohesion Installer, refer Installing software. 1. HOME: View all modules in the chassis 2.
7.1 Access a module with CohesionUI You can access Quantifi Photonics modules via CohesionUI from the chassis controller, or from a controller PC . To connect with a module, you need the IP address of the chassis the module is installed in.
7.2 Display modules in a chassis The HOME page is the main landing page in CohesionUI; it displays all available Quantifi Photonics modules in the PXIe chassis. 1. Numbers indicate the slots the modules are installed in. 2. You can hide (default setting) or show empty slots in the PXIe chassis by toggling the EMPTY SLOTS button.
1. Go to the HOME page. 2. Click the on the module. 3. Or, hover over the MODULES menu and select a module or channel from the list. 24 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
To set a pre-defined value, for example MIN, MAX or DEF: 4. Click on a parameter and select a value from the dropdown menu. 5. Confirm the value. 25 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
: The actual value of the parameter as queried by the product. SET: The intended value of a given parameter as set by the user. For details on how to set values, refer values. 26 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Please note that the units displayed on this page are not always relevant for each product. 3. Step size refers to the amount by which a value is increased or decreased when clicking the + or - button. 27 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Page 28
To adjust unit preferences one at a time: 1. Hover over SETTINGS. 2. Select a unit from the dropdown, for example the power unit. 28 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
7.7 Synchronize and reinitialize CohesionUI You can update CohesionUI with the latest information from your Quantifi Photonics modules by synchronizing or reinitializing. Synchronizing Updates CohesionUI with the latest information from the CohesionSCPI service Reinitializing Updates CohesionUI and the CohesionSCPI service with the latest information from the CohesionDriver service This can be particularly useful when operating a multi-chassis MXI setup and enables you to: ...
Page 30
To reinitialize CohesionUI across all modules in all chassis: 1. Click SETTINGS. 2. Click RE-INIT. 3. All modules will be disabled and temporarily disconnected while reinitializing. 30 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
7.8 SCPI CohesionUI Command Console The CohesionUI SCPI Command Console enables you to communicate with Quantifi Photonics PXIe modules via SCPI commands. It enables you to test commands and verify their syntax. For details on available SCPI commands, refer to the programming guide in this manual.
Page 32
Clear the response buffer and start fresh – *CLS useful when getting out of sync with WRITE and READ actions 32 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Page 33
8. The instrument returns the error code, for example 32. For details on error codes, please refer to the *ESR? command in the programming guide. 33 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
To view module information when working with a module in CohesionUI: 1. Model number, serial number and firmware versions are displayed in the top right corner. 34 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
8 Controlling your LASER with CohesionUI You can use Quantifi Photonics' graphical user interface CohesionUI to work with your LASER module. For details on how to get started with CohesionUI, refer to CohesionUI - Overview. In CohesionUI you can: Set channel parameter values.
After toggling the STATE button from OFF to ON, the Laser product will take up to 30 seconds to stabilise its power and frequency. CohesionUI will be unresponsive during this time. 36 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
[VALUE1] or [VALUE2] can be used, but not both. Some commands may have more than two choices available. This parameter can be omitted where the command has a default defined in the command description. 37 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Unless specified, all output response data is transmitted in ASCII format. 9.3 Status and event registers 9.3.1 Standard Event Status Register The Standard Event Status Register (SESR) is modified by the Quantifi Photonics product with the results of the command operations. Description 7 (MSB), 6...
The Event Status Bit (ESB) is set from the SESR and the SESR Mask Message Available (MAV) is set when there is data in the output queue 3, 2, 1, 0 (LSB) Not used 39 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
In the example shown below, there are two chassis connected via the PXIe-8384 to PXIe-8381 connection. Chassis #2 has the controller running CohesionSCPI service, and Chassis #3 is the ‘extended’ chassis. 41 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
:SYSTEM:CHASSIS SINGLE In Multi chassis mode, all commands listed in the command summary section will still work, but they must be prefixed with :CHASSIS<c>. 42 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Page 43
Common command example: Single Chassis :SLOT2:IDN? Mode Multi Chassis :CHASSIS1:SLOT2:IDN? Mode Specific command example: Single Chassis :SOUR2:CHAN2:POW? MAX Mode Multi Chassis :CHASSIS1:SOUR2:CHAN2:POW? MAX Mode 43 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Query the Operation Complete Status of the module >> :OPTions? Query the modules managed by the CohesionSCPI service >> :IDN? Query the slot identification 44 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
>> :WAVelength Set the laser wavelength >> :FREQuency? Query the laser frequency >> :FREQuency Set the laser frequency >> :TEMPerature? Query the laser temperature 45 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Query the modules managed by the CohesionSCPI service Parameters Response Comma separated string of the installed modules in the chassis Example *OPT? -> ,LASER-2001-1-FA-PXIE,SWITCH-1003-1-FC-PXIE,,VOA-1001-2-FA-PXIE,,,,O2E-1001-1- FC-PXIE,,,,,,,,, 46 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Page 47
Execution Error – SCPI was unable to execute the given command. Command Error – SCPI was unable to parse the given command, likely due to an incorrect command. 47 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
A comma-separated string containing "<manufacturer>,<model name>,<serial number>,<hardware version><firmware version>". Note that the hardware and firmware versions are not comma separated. Example :SLOT1:IDN? -> Quantifi Photonics,LaserPXIe-1002-2-FA,QuantifiPhotonics-192001,HW1.0FW1.021,QP- 000000,HW0.00.01FW0.00.01 48 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Set the optical output state of the laser Parameters ON: Enable the laser output OFF: Disable the laser output Response Example :OUTP1:CHAN1:STATE ON 49 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Page 50
Response A single value, or a comma-separated array of values Example :SOUR1:CHAN1:WAV? -> 1.550116e-06 :SOUR1:CHAN1:WAV? MAX -> 1.568773e-06 :SOUR1:CHAN1:WAV? ALL -> 1.527605e-06,1.568773e-06,1.548928e-06,1.550000e-06,1.550116e-06 50 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Page 51
<value>: A valid numerical value which is in the range between the MIN and MAX frequency values Response Example :SOUR1:CHAN1:FREQ 1.92e+14 51 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Page 52
Summary >> :SOURce<n>:CHANnel<m>:TEMPerature? Syntax :SOURce<n>:CHANnel<m>:TEMPerature? >> Description Query the laser temperature Parameters Response Temperature in Celsius Example :SOUR1:CHAN1:TEMP? -> 49.99000168 52 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
After setting the Laser STATE to ON, allow 30 seconds for the laser power and frequency to stabilize and reach the set point. Any POWER or FREQUENCY (WAVELENGTH) queries during this time may return incorrect information. 53 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
In NI-MAX a RIO interface will show up, however there are no communication methods available or implemented on this interface. Quantifi Photonics products are ONLY accessible through the VISA TCPIP INSTR interface provided by the CohesionSCPI service installed on the system.
3. Select Manual Entry of LAN Instrument. Enter in the Hostname or IP Address. Note when operating locally, enter in the localhost IP address of 127.0.0.1. Click Finish to end the setup process. 55 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
2. On the right-hand side panel, select Open VISA Test Panel. A new window will popup. Click the Input / Output button from the window menu. Valid chassis and module commands can be entered in, and their returns queried 56 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
10.3 Python® 2.7 code example The following example shows how to communicate with the Quantifi Photonics product using Python code. # You can get VXI11 from pip: # pip install python-vxi11==0.9 import vxi11 from vxi11.vxi11 import Vxi11Exception # replace this with the IP of your device ip = "127.0.0.1"...
10.4 MATLAB® code example To communicate with the Quantifi Photonics product in MATLAB® the installation of a VISA IO driver is required. These drivers enable the creation of the Interface Object for instrument communication. If developing locally on the PXIe Platform, then these will already be installed. However, if development is on a remotely connected system the VISA Libraries, e.g.
Always inspect fiber end faces for cleanliness using a fiber inspection probe before inserting them into a port.. If required, clean fibers and faces as detailed below. Quantifi Photonics is not responsible for damage or errors caused by bad fiber cleaning or handling. NOTE To avoid damaging ferrules or fiber faces due to mismatched connectors, always check ports and connector type information before inserting a connector.
Page 60
NOTE Failing to align and/or connect fiber-optic cables properly will result in significant signal loss and reflection. 60 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Quantifi Photonics MATRIQ / EPIQ instruments Google Chrome™ Supported browsers for working with CohesionUI Microsoft Edge® Recommended client computer operating system Microsoft Windows® 10 (64-bit) 61 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
All Quantifi Photonics products are calibrated during manufacture, and each product is shipped to the customer with a Calibration Certificate. On this certificate, the calibration date, as well as the next calibration due date are mentioned.
Avoid high humidity or large temperature fluctuations. Keep the product out of direct sunlight. Avoid unnecessary shocks and vibrations. 63 / 66 Quantifi Photonics | LASER 1100 Series PXIe User Manual | Document version 2.00...
Quantifi Photonics shall not be liable for damages resulting from improper usage, transportation or unauthorized modification of the product, its accompanying accessories and software. The external power supply that has been supplied by Quantifi Photonics with the unit can only be used with that unit, do not use it with any other product.
Quantifi Photonics. 15.4 Certification Quantifi Photonics certifies that this equipment met its published specifications at the time of shipment from the factory. 15.5 Service and repairs To send any equipment for service, repair or calibration please contact the Technical Support Group: support@quantifiphotonics.com.
Page 66
Measure. Solve. Quantifi Photonics is transforming the world of photonics test and measurement. Our portfolio of optical and electrical test instruments is rapidly expanding to meet the needs of engineers and scientists around the globe. From enabling ground- breaking experiments to driving highly efficient production testing, you'll find us working with customers to solve complex problems with optimal solutions.