Download Print this page

Restoration Hardware KNURLED RH-8940X Installation Instructions Manual

Shower bp set

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS
SHOWER BP SET
MODEL: KNURLED
(RH-8940X)
1
REV -

Advertisement

loading

Summary of Contents for Restoration Hardware KNURLED RH-8940X

  • Page 1 INSTALLATION INSTRUCTIONS SHOWER BP SET MODEL: KNURLED (RH-8940X) REV -...
  • Page 2 Restoration Hardware Balance Pressure Shower Set Specification Diagram Note: This valve is designed to fit in a 2” X 4” stud wall (or thicker) installation. Use stem extension kit #RH-1-384 (sold separately) if valve installed is too far away from finished wall).
  • Page 3: Common Tools Needed

    Common tools needed: Plumbers Pipe Putty Wrench Adjustable Perforated Wrench Assorted Thread Pipe Strap and Screwdrivers Sealant Cutter Clamp Installation Instructions We Recommend Installation by a Licensed Plumbing Professional Valve Assembly Position VALVE (1) with the “S” in the up position The VALVES (1) 1/2”...
  • Page 4 Setting The Temperature Limit Stop Remove the HEX NUT (8), all-thread NIPPLE (4), RETAINING SCREWS (5) RETAINING PLATE (3) and STEM (2) from the VALVE COVER. Remove the LIMIT STOP (6) see figure 2. Do not remove the MECHANICAL STOP (7). (If for any rea- son the MECHANICAL STOP (7) is removed refer to Cartridge Removal and Replace section below.) From the CLOSED position, rotate the CARTRIDGE STEM counter-clockwise until the desired temper-...
  • Page 5 Cartridge Removal And Replacement Remove the HEX NUT (8), all-thread NIPPLE (4), RETAINING SCREWS (5), RETAINING PLATE (3) and STEM (2) from the VALVE COVER. Remove the LIMIT STOP (6) and MECHANICAL STOP (7). Remove the COVER SCREWS (9), VALVE COVER and cover O-RING (Not shown). Carefully slide the CARTRIDGE STEM out of VALVE BODY.
  • Page 6 Valve Trim Installation (Perform these steps after finished wall has been completed) The STEM (3) must be trimmed to 1-3/4” from finished wall. Remove STEM (3) by loosening NUT (2) and removing NIPPLE (1), NUT (2) and STEM (3). Trim STEM (3) to previously mentioned dimension. The NIPPLE (1) must be trimmed to 7/8”...
  • Page 7: Troubleshooting

    Test Installed Shower Set Turn on the shower valve by rotating the handle counter-clockwise. Water mixing temperature to handle rotation is as follows: 1/4 to 1/2 = warm 1/2 to 3/4 = hot 0 to 1/4 = cold 1/4 to 1/2 = warm 1/2 to 3/4 = hot Trouble Shooting WARNING: At no time try to stop dripping by applying extreme force or overtightening the handle.
  • Page 8 Care and Cleaning The lustrous finish on your Restoration Hardware Bathware fixture should be treated with care. Improper handling or cleaning can damage the sur- face of any metal finish. Use a soft cloth to wipe clean. Avoid harsh abra- sive cleaner.