Telefire TDM-500i Technical Manual

Intelligent dialer

Advertisement

Quick Links

T
F
& G
D
ELEFIRE
IRE
AS
ETECTORS
PO Box 7036
Petach Tikva 49250
Israel
Tel:
972 3 921 1955
Fax:
972 3 921 1816
eMail:
marketing@telefire.co.il
Web:
www.telefire.co.il
L
TD
TDM-500i
Intelligent Dialer
Technical Manual
TDM- - - - 500i
TDM
TDM
TDM
Revision 1.12
July 2012
500iEn
En112
112.pdf
.pdf
500i
500i
En
En
112
112
.pdf
.pdf

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TDM-500i and is the answer not in the manual?

Questions and answers

Summary of Contents for Telefire TDM-500i

  • Page 1 TDM-500i Intelligent Dialer Technical Manual & G ELEFIRE ETECTORS PO Box 7036 Petach Tikva 49250 TDM- - - - 500i 500iEn En112 112.pdf .pdf 500i 500i .pdf .pdf Israel Tel: 972 3 921 1955 Fax: 972 3 921 1816 Revision 1.12 eMail: marketing@telefire.co.il...
  • Page 2 © 2006 – 2012 Telefire Fire & Gas Detectors Ltd Revision 1.12 July 2012 Introduction Telefire’s TDM-500i Intelligent Dialer is intended for use in fire-, security- and safety detection systems to automatically dial and play pre-recorded voice messages on alarm and trouble events to emergency services and key personnel.
  • Page 3: Installation

    GSA-2B • Installation The TDM-500i dialer can be installed either in close proximity to the control panel or at a distance, as the control lines are monitored. The dialer’s enclosure includes wire openings. Do not drill holes in the enclosure.
  • Page 4 TDM-500i © 2006 – 2012 Telefire Fire & Gas Detectors Ltd Revision 1.12 July 2012 Press Display Programming Range Factory Default Delay in Seconds – 1 – 9 delay while dialing through switchboards Message Repeats 1 – 9 Event latching 0 / 1 0 –...
  • Page 5 TDM-500i © 2006 – 2012 Telefire Fire & Gas Detectors Ltd Revision 1.12 July 2012 Output Voltage Voltage Factory Press Display Output Programming between between Default CNT and CNT and +24V +12V The display 00 – output not used will show the 10 –...
  • Page 6 TDM-500i © 2006 – 2012 Telefire Fire & Gas Detectors Ltd Revision 1.12 July 2012 Displaying the dialing list will cause the following number sequence: 039211955 039211816 Sequence Phone number Sequence Phone number Available space Printing Dialing List and Configuration Press Prog –...
  • Page 7: Changing Password

    TDM-500i © 2006 – 2012 Telefire Fire & Gas Detectors Ltd Revision 1.12 July 2012 Press Display Program Press Enter and record Message A Press Enter and record Message B Press Enter and record Message C Play back message A.
  • Page 8: Connection Diagrams

    TelCo Line Error – Buzzer Silencing The telephone line is supervised. When there is no connection the TDM-500i will beep as an indication that there is a line failure. Press the Exit key for a few seconds to silence the buzzer.
  • Page 9 TDM-500i © 2006 – 2012 Telefire Fire & Gas Detectors Ltd Revision 1.12 July 2012 Connecting a TDM-500i to a TSA-1000 / TSA-1000X Connecting a TDM-500i to a TSA-200 / TSA-200XT / TSA-200X – Page 8 of 10 –...
  • Page 10 TDM-500i © 2006 – 2012 Telefire Fire & Gas Detectors Ltd Revision 1.12 July 2012 Connecting a TDM-500i to a GSA-1000 Connecting a TDM-500i to a GSA-2B – Page 9 of 10 –...
  • Page 11: Specification

    TDM-500i © 2006 – 2012 Telefire Fire & Gas Detectors Ltd Revision 1.12 July 2012 Connecting a TDM-500i or a TDM-500i/12 to a Generic Control Panel Specification Dimensions (W / H / D) ..........167 / 125 / 33 mm Weight ................