Guidelines that apply to Intelbras employees » Intelbras employees are subject to safe trading practices and data confidentiality under the terms of the company's work procedures. » It is imperative that the following rules are observed to ensure that statutory provisions relating to services (be they in-house services or remote administration and maintenance) are strictly followed.
Preparing for installation This document is applicable to the following Ethernet switches: Table 1 Switch series and models Switch series Model SC 3570-24G-4X SC 3570-48G-6X SC 3570-24GP-4X SC 3570 switch series SC 3570-48GP-6X SC 3570-24S-8G-4X SC 3570-48S-6X Safety recommendations To avoid any equipment damage or bodily injury caused by improper use, read the following safety recommendations before installation.
High temperature can accelerate the aging of insulation materials and significantly lower the reliability and lifespan of the switch. For the temperature and humidity requirements of the switch, see technical specifications in Intelbras SC 3570 Switch Series Hardware Information and Specifications. CAUTION: Ground the switch correctly and verify the grounding.
Item Requirements corresponding network interface. • Keep the signal cables far from power cords and lightning rod down conductors. • As a best practice, route power cords indoors. If an AC power cord is routed from outdoors, connect the AC power cord first to a power lightning arrester before leading it to the AC power port on the switch.
• Use double-layer glass in windows and seal doors and windows with dust-proof rubber strips. Use screen doors and window screens for doors and windows open to the outside and make sure the external windows are air tight. • Use dustproof materials for floors, walls, and ceilings and use wallpaper or matt paint that does not produce powders.
Examining the installation site Before you install the switch, verify that the installation site meets the installation requirements. The switch can operate correctly in an A1 or A2 installation site. Availability issues might occur if you install the switch in an A3, B1, B2, or C installation site. Table 5 Installation sites Category Definition...
The power supply must be available before you install the switch. The voltage provided to the switch must be within the operating voltage range. Voltage For the operating voltage range, see Intelbras SC 3570 Switch Series Hardware Information and Specifications. •...
Page 11
All models 1, provided with removable power supplies DC power cord 1, provided with DC power SC 3570 series supplies AC power cord bail latch SC 3570-24G-4X 1, provided with SC 3570-48G-6X the CA-70A12 and PSR75-12A SC 3570-24S-8G-4X...
Page 12
Code Description Quantity Applicable device models might differ. DB9-to-RJ45 console cable 04042967 1, optional All models USB-to-RJ45 console cable 0404A1EE 1, optional All models 1, provided with PSR180-56A, PSR360-56A, Releasable cable tie PSR720-56A, SC 3570-24GP-4X PSR1110-56A, SC 3570-48GP-6X PSR600-54A-B, PSR920-54A-B, PSR1600-54A-B power supplies...
CAUTION: Keep the tamper-proof seal on a mounting screw on the chassis cover intact, and if you want to open the chassis, contact Intelbras for permission. Otherwise, Intelbras shall not be liable for any consequence. Figure 1 Hardware installation flow...
Rack-mounting the switch by using front mounting brackets The installation procedures are the same for the SC 3570 series. The following uses the SC 3570-48S-6X as an example.
Page 15
To attach the front mounting brackets to the chassis: Place the wide flange of the mounting bracket against the chassis side panel. Align the mounting bracket installation holes with the screw holes in the chassis. To install the mounting brackets at the port-side mounting position, see Figure ...
Page 16
Attach cage nuts to the front rack posts. One person supports the bottom of the switch, and moves the switch to an appropriate position based on the installation positions of the front mounting brackets. Another person uses user supplied M6 screws and cage nuts to attach the mounting brackets to the rack and verifies that the brackets are level and secure.
Mounting the switch on a workbench IMPORTANT: • Reserve a minimum clearance of 10 cm (3.9 in) around the chassis for heat dissipation. • Do not place heavy objects on the switch. To mount the switch on a workbench: Verify that the workbench is sturdy and reliably grounded. Place the switch with bottom up, and clean the round holes in the chassis bottom with dry cloth.
IMPORTANT: Orient the grounding cable as shown in Figure 8 so that you can easily install or remove the removable components. Figure 8 Connecting the grounding cable to the chassis (1) Grounding screw (2) Ring terminal (3) Grounding sign (4) Grounding hole (5) Grounding cable Connecting the grounding cable to a grounding strip Use needle-nose pliers to bend the bare metal part to the shape as shown in...
The dimensions of the angle iron must be a minimum of 50 × 50 × 5 mm (1.97 × 1.97 × 0.20 in). The steel tube must be zinc-coated and its wall thickness must be at least 3.5 mm (0.14 in). Weld the yellow-green grounding cable to the angel iron or steel tube and treat the joint for corrosion protection.
Page 20
The SC 3570 switch series provides two power supply slots. You can install one or two power supplies for the switch as required. For the power supplies available for the switch and their specifications, see Intelbras SC 3570 Switch Series Hardware Information and Specifications. The SC 3570-24G-4X, SC 3570-48G-6X, SC 3570-24S-8G-4X-GL, SC 3570-48S-6X, SC 3570-24GP-4X, and SC 3570-48GP-6X switches are shipped with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel.
Installing/removing a power supply (1) This section applies to the CA-70A12, PSR75-12A, and PSR150-D1 power supplies, which use a similar installation/removal procedure. A PSR75-12A power supply is used as an example. Installing a power supply Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded. Remove the filler panel from the target power supply slot as follows: a.
Figure 14 Installing a power supply Removing a power supply Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded. Disconnect the power cord. Loosen the captive screws on the power supply with a Phillips screwdriver until they are completely disengaged.
Page 23
Remove the filler panel, if any, from the target power supply slot. Put your forefinger into the hole in the filler panel and then pull the filler panel out of the slot gently. Keep the removed filler panel secure for future use. Figure 16 Removing the filler panel from the target power supply slot Unpack the power supply.
Page 24
Figure 18 Installation completed NOTE: The PSR1110-56A power supply, including its handle, adds 64 mm (2.52 in) to chassis depth. Removing a power supply Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded. Disconnect the power cord.
Connecting the power cord CAUTION: • CA-70A12 and PSR75-12A power supplies use C13 power cords, and PSR180-56A, PSR360-56A, PSR720-56A, PSR1110-56A, PSR600-54A-B, PSR920-54A-B, and PSR1600-54A-B power supplies use C15 power cords (used in high temperature). Do not mix power cords for different power supplies. •...
Figure 20 Connecting the power cord for a built-in power supply(1) Figure 21 Connecting the power cord for a built-in power supply(2) Connecting the power cord for a CA-70A12 or PSR75-12A power supply The power cord connection procedure is similar for the CA-70A12 and PSR75-12A power supplies. The following procedure connects the power cord for a PSR75-12A power supply.
• To use a –48 VDC power source to supply power to the power supply, use the DC power cord supplied with the power supply. • To use an Intelbras RPS (–54 VDC) to supply power to the power supply, use a compatible RPS power cord to connect the RPS to the power supply.
Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded. Unpack the power cord, correctly orient the plug at one end of the cable with the power receptacle on the power supply, and insert the plug into the power receptacle (see callout 1 Figure 24).
Figure 25 Connecting the power cord for a PSR360-56A power supply Verifying the installation Before powering on the switch, verify the following items: • There is enough space around the switch for heat dissipation. • The rack or workbench on which the switch is mounted is stable. •...
Accessing the switch for the first time Connecting the switch to a configuration terminal The SC 3570 series switches provide a serial console for connecting to a configuration terminal. Figure 26, the switch is connected to a configuration terminal (PC as an example) from the serial console port.
A DB9-to-RJ45 console cable is an 8-core shielded cable, with a crimped RJ-45 connector at one end for connecting to the serial console port of the switch, and a DB-9 female connector at the other end for connecting to the serial port on the console terminal. Figure 27 DB9-to-RJ45 console cable A side Pin 9...
Setting terminal parameters To configure and manage the switch through the console port, you must run a terminal emulator program, such as TeraTermPro, on your configuration terminal. You can use the emulator program to connect a network device, a Telnet site, or an SSH site. For more information about the terminal emulator programs, see the user guides for these programs.
Setting up an IRF fabric (Stacking) You can use Intelbras IRF technology to connect and virtualize SC 3570 switches into a large virtual switch called an "IRF fabric" for flattened network topology, and high availability, scalability, and manageability. A SC 3570 switch can set up an IRF fabric only with switches from the same switch series.
Step Description • Identifying physical IRF ports on the member switches • Planning the cabling scheme "Installing the switch in a 19-inch rack" or "Mounting the switch Install IRF member switches on a workbench." Connect grounding cables and "Grounding the switch"...
Planning IRF topology and connections You can create an IRF fabric in daisy chain topology or more reliable ring topology. In ring topology, the failure of one IRF link does not cause the IRF fabric to split as in daisy chain topology. Instead, the IRF fabric changes to a daisy chain topology without interrupting network services.
SFP port—GE SFP fiber transceiver module and optical fiber, GE SFP copper transceiver module and twisted pair cable or GE SFP cable. For the available transceiver models and cables, see ports in Intelbras SC 3570 Switch Series Hardware Information and Specifications. •...
Page 37
The following subsections describe several Intelbras recommended IRF connection schemes by using SFP+ cables and SFP+ transceiver modules and fibers. All these schemes use a ring topology. IMPORTANT: In these schemes, all physical IRF ports are located on the same side. If physical IRF ports are on different sides, you must measure the distance between them to select an appropriate cable.
Connect the IRF member switches as planned. Wear an ESD wrist strap when you connect cables or transceiver modules and fibers. For how to connect them, see Intelbras Transceiver Modules and Network Cables Installation Guide. Verifying the IRF fabric setup...
Page 39
Table 15 Displaying and maintaining IRF configuration and running status Task Command display irf Display information about the IRF fabric. Display all members’ IRF configurations that take display irf configuration effect at a reboot. display irf topology Display IRF fabric topology information. NOTE: To avoid IP address collision and network problems, configure a minimum of one multi-active detection (MAD) mechanism to detect the presence of multiple identical IRF fabrics and handle...
Symptom The system status LED on the switch indicates a fan tray failure. Solution When a fan tray issue occurs, contact Intelbras Support. Configuration terminal display issues If the configuration environment setup is correct, the configuration terminal displays booting information when the switch is powered on. If the setup is incorrect, the configuration terminal...
Page 41
Verify that the power supply is supplying power to the switch correctly. Verify that the console cable is correctly connected. Verify that the console cable does not have any issues and the terminal settings are correct. If the issue persists, contact Intelbras Support. Garbled display Symptom The display on the configuration terminal is garbled.
Page 42
Consumer makes a regular backup copy of the data contained in the product. 7. Intelbras is not responsible for the installation of this product, nor for any attempts at fraud and/or sabotage in its products. Keep the software and applications used up to date, if applicable, as well as the necessary network protections to protect against intrusions (hackers).
Page 43
A garantia contratual deste termo é complementar à legal, portanto, a Intelbras S/A reserva-se o direito de alterar as características gerais, técnicas e estéticas de seus produtos sem aviso prévio.
Need help?
Do you have a question about the SC 3570 Series and is the answer not in the manual?
Questions and answers