6.
Adjust the color temperature ~~ Two methods can be used to adjust RED, GREEN, BLUE value of
each color temperature, C0/Cool, C1/User & C2/Warm to meet following spec requirement, the 1
using external PC and IIC alignment protocol to do automatic adjustment, and the 2
and must be in factory mode.
Color temperature
(C0/cool
on OSD)
Color temperature
(C2/Warm
on OSD)
Color temperature
(C1/User
on OSD)
7. Move cursor into "Burn-in Mode" tag and select "No" to disable burn-in mode.
8. Turns off the monitor power.
5.1.5. Writing EDID data into monitor
1.
Setup a PC with DDC card.
2.
Connect PC to monitor with a D-sub signal cable.
3.
Please refer to the Q212 for the correct EDID file.
4.
Runs the writing program to write the analog EDID data into EEPROM for analog input(ie. 15-pin D-
sub).
5.
Repeat step 4 and write the digital EDID data into EEPROM for DVI-D input(ie. 24-pin DVI-D).
6.
Read both EEPROM data and confirm it to match with the C212 definition.
(Note : The DVI-D input may not operation correctly if the digital EDID data do not exist.)
X+-
Y+-
Luminance
X+-
Y+-
Luminance
X+-
Y+-
Luminance
- 39 -
st
nd
method is by manually
0.283+(-) 0.03
0.297+(-) 0.03
> 180 cd/m²
0.313+(-) 0.03
0.329+(-) 0.03
> 220 cd/m²