Arc-Zone AZP-BT-003182-110V Operation Manual

Water cooling system

Advertisement

Quick Links

OPERATIONS
MANUAL
Model:
AZP-BT-003182-110V
Water Cooling System
AZP-BT-003182-110V
Water Cooling System
OPERATIONS MANUAL
From
www.arc-zone.com
info@arc-zone.com
Sold By:
(760) 931-1500
ArcZone
@ArcZone
@Arc_Zone
ArcZoneVideos

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AZP-BT-003182-110V and is the answer not in the manual?

Questions and answers

Summary of Contents for Arc-Zone AZP-BT-003182-110V

  • Page 1 AZP-BT-003182-110V Water Cooling System OPERATIONS OPERATIONS MANUAL MANUAL From Sold By: Model: www.arc-zone.com info@arc-zone.com AZP-BT-003182-110V (760) 931-1500 ArcZone Water Cooling System @ArcZone @Arc_Zone ArcZoneVideos...
  • Page 2: Table Of Contents

    Arc-Zone�com, Inc tests and inspects all new water coolers and warrants them against defects in material and worksmanship� Arc-Zone will warranty the water cooler for 90 days from the date of purchase� This warranty is expressly limited to replacement or repair of the defect based on the evaluation of an Arc-Zone Technician and excludes consumable parts that wear as a part of normal operation�...
  • Page 3: Introduction

    • Use the electric shock prevention device when operating in tight spaces� • Please turn off the water cooler power switch to avoid electric shook� Arc-Zone.com, Inc. • 1331 Specialty Dr. • Vista, CA 92081 Tel. 1.760.931.1500 • Email: info@arc-zone.com...
  • Page 4: Configuration

    Easy to operate, no exhaust required� • Built-in intelligent control panel, transformer, and independent fan provide stabilize heat dissipation� • Overload protection ensures long life� Arc-Zone.com, Inc. • 1331 Specialty Dr. • Vista, CA 92081 Tel. 1.760.931.1500 • Email: info@arc-zone.com...
  • Page 5: Tech Specs

    23 in x 13 in x 15 in Weight 45 lbs (20kg) Storage Temperature 14 °F - 131 °F Working Environment Temperature 23 °F - 104 °F Arc-Zone.com, Inc. • 1331 Specialty Dr. • Vista, CA 92081 Tel. 1.760.931.1500 • Email: info@arc-zone.com...
  • Page 6: Front-Panel Components

    (Note: there is a small amount of water stored in the condenser. Use compressed air on the return water joint to blow water into the tank.) Arc-Zone.com, Inc. • 1331 Specialty Dr. • Vista, CA 92081 Tel. 1.760.931.1500 • Email: info@arc-zone.com...
  • Page 7: Cycle Checklist

    Cooling Fan and electrical Screw up and add lube Half a year wire is loose Pump Joint Leak Screw up and replacing Half a year Arc-Zone.com, Inc. • 1331 Specialty Dr. • Vista, CA 92081 Tel. 1.760.931.1500 • Email: info@arc-zone.com...
  • Page 8: Troubleshooting Unit

    (inlet of the pump) flowing out 2� There is a problem with water 2� Check and repair water pump pump Wiring Diagram Arc-Zone.com, Inc. • 1331 Specialty Dr. • Vista, CA 92081 Tel. 1.760.931.1500 • Email: info@arc-zone.com...

Table of Contents