CATALOGUE NR: JPD-HA120
PRODUCT COMPOSITION
The product is comprised of the host machine and the cuff of Electronic Blood Pressure
Monitor.
INTENDED USE
The Electronic Blood Pressure Monitor is intended to measure the systolic and diastolic
blood pressure as well as the pulse rate of adult person via non-invasive oscillometric
technique at medical facilities or at home
SAFETY PRECAUTIONS
Legend, mark and meaning
Warning message
Anti-electric shock degree is Type BF of the application part
When the product life expires and the end users discard the
products, send them to the designated collecting and separating
place for disposal according to the requirements from the local
environmental protection authority.
Consult the instructions for use.
This product complies with the MDD93/42/EEC requirements.
IP21
Degree of protection against the ingress of water.
Information of manufacturer
Date of manufacture
Authorized European Representative
Avoid smoking, eating, drinking caffeinated drinks or exercising for 30 minutes before
taking measurement.
1. Sit upright in a chair with both feet on the floor.
2. Remove tight fitting clothing from your upper arm along
with any thick clothing
3. Pull on the end of the cuff until it wraps securely around
your upper arm. Place your arm on a table so that the cuff will
be at the same level as your heart.
4. The cuff will automatically inflate and the measurement will
English
start, upon pressing the "START/STOP" button.
English
5. When the measurement is complete, the cuff will
automatically deflate and your systolic and diastolic pressure
values and
rate will be
displayed.
Monitor
Universal Cuff
99 Readings * 2 Users
Average of last 3 readings
Irregular Heartbeat Detector
Auto-off Power Saving Feature
Bluetooth Transmission Function
Operated by 4 AA batteries (USB 5V optional)
QUICK START GUIDE
.
pulse
OVERVIEW
Display
Packing List
No.
1
Electronic Blood Pressure Monitor
2
Cuff
3
Dry Battery (AA)
4
User Manual
5
Zipped Cattying Bag
PREPARATION
2.1 Battery Installation
a)Open the battery cover as shown in the picture.
b ) Place 4 AA dry batteries. Pay attention to the
battery electrode indication.
2.2
Battery
power
indication
replacement
After the product is turned on, if low power symbol
measurement cannot be performed, and the battery must be replaced.
Features
Do not use any expired battery;
If the product is not used for over 3 months, please
take out the batteries.
2.3 USB Power Supply
USB line can be connected for power supply of the product without battery
2.4 Cuff
The applicable arm circumference range of the cuff is 22-36cm or 22-42cm.
Connection: Insert the air plug of cuff air tube into air jack of the Electronic Blood Pressure
Monitor. Figure shown as above:
Name
Quantity
1
1
4
1
1
and
appears on the screen , the
.

Advertisement

loading
Need help?

Need help?

Do you have a question about the JPD-HA120 and is the answer not in the manual?

Questions and answers

Summary of Contents for Screen JPD-HA120

  • Page 1 After the product is turned on, if low power symbol appears on the screen , the This product complies with the MDD93/42/EEC requirements. measurement cannot be performed, and the battery must be replaced. Features Do not use any expired battery;...
  • Page 2 (1) Press the “START/STOP” button, and the device will return to zero automatically, the air pump will start to inflate the cuff, and the screen will display the change of the pressure in the cuff.
  • Page 3 “Err 1” displayed work. service. Product Name Electronic Blood Pressure Monitor Please check if the cuff wearing Model JPD-HA120 “Err 2” displayed No pulse detected is correct, and follow Section 4.1 How to use the cuff Display Mode Digital display mode...
  • Page 4 28 V/m 28 V/m Website:www.jumper-medical.com deviation: 1kHz sine Distributed by: 710 MHz **Pulse 0.2 W 9 V/m 9 V/m Screen Italia Srl 745 MHz Modulation: Via dell’Artigianato, 16 780 MHz 217Hz 06089 - Torgiano - Perugia - Italia www.screenpharma.it - info@screenpharma.it...

This manual is also suitable for:

970791796