4.3. Troubleshooting
It is possible to save images created by the coplanarity checker. See chapter 3.3.2.4 for more
information.
For troubleshooting purposes the following error messages are available on the AX-201 :
1. Coplanarity : Communication error
•
Description:
o Communication with the coplanarity checker failed.
•
Cause:
o The network between APC and coplanarity checker not connected.
o The coplanarity checker unit is not correctly started.
o The coplanarity checker communication ip and/or port wrong configured.
•
Action:
o Check the network connection between the APC and coplanarity checker PC.
o Power failure on the coplanarity checker.
o Check IP address and port in the CPL configuration file. (See chapter 3.3.1.2)
2. Coplanarity : Communication error
•
Description:
o Communication with the coplanarity checker failed, network is available.
•
Cause:
o Wrong serial number of coplanarity checker is configured.
•
Action:
o Check 'SETTINGS.XML' file in the '\user\aPC\config\machine\' directory for correct
serial number. (see chapter 3.3.2.2)
3. Coplanarity : Component definition not defined for coplanarity
•
Description:
o The component definition is not found in the 'SETTINGS.XML' file. This file describes
the component definition for the coplanarity checker.
•
Cause:
o The component description entry is not in the 'SETTINGS.XML' file on the aPC.
•
Action:
o Open the 'SETTINGS.XML' file in the '\user\aPC\config\machine\' directory and add
the component coplanarity information in this file to solve this problem.
4. Coplanarity : Measurement timeout
•
Description:
o Process error: Component measurement timeout.
•
Cause:
o Coplanarity checker didn't reply within specified maximum measurement time.
o Coplanarity checker obstructed.
•
Action:
o Measurement timeout specified in configuration file CPL.CFG is too small!
o Check the laser window and remove the obstruction (e.g. components).
o Clean glass plate; see the maintenance chapter for instructions.
33