Do you have a question about the 101-533.NG001 and is the answer not in the manual?
Questions and answers
Summary of Contents for Anschutz 101-533.NG001
Page 1
Anschütz GmbH Zeyestr. 16-24 24106 Kiel Germany www.anschuetz.com Feedback Signal Converter AS Operator and Service Manual Type: 101-533.NG001 Edition: 001 10000001298...
Page 2
Copyright Dieses Dokument sowie dessen Inhalt sind urheberrechtlich This document and its content are copyright protected. Distribution, geschützt. Die Weitergabe,Vervielfältigung und Speicherung sowie reproduction and storage as well as translation and exploitation of die Übersetzung wie auch Verwendung dieses Dokuments oder this document and its content, in whole or in parts and regardless of dessen Inhalts, als Ganzes oder in Teilen und egal in welcher Form what form, are prohibited without prior express written permission.
Feedback Signal Converter AS Table of Contents Table of Contents List of Figures..............................III List of Tables................................ V List of Abbreviations............................VII Introduction................................ 1 Preliminary Remarks............................. 1 Change History.............................. 1 Safety................................1 General Safety Regulations........................1 General Safety Instructions........................2 Electrostatic Discharge..........................2 List of Further Documents..........................3 List of Annex Documents..........................
Page 4
Feedback Signal Converter AS Table of Contents 3.3.3.1 General Remarks about Preparing Cable Connections............12 3.3.3.2 General Remarks about Preparing Common Ground Connections........14 3.3.3.3 CAN Bus Module / Service Tool Connections..............14 3.4 Care and Maintenance........................... 16 3.5 Maintenance and Repair........................16 4 Transport and Storage..........................17 4.1 Preservation, Packing and Storage.......................
Feedback Signal Converter AS List of Figures List of Figures Fig. 1: Electrostatic Discharge, Protected Area..................... 2 Fig. 2: CAN Bus Module, Connections and Indicators...................5 Fig. 3: CAN Bus, Jumper for Termination......................6 Fig. 4: Prepare a Cable Connection........................12 Fig. 5: Prepare a Cable Entry..........................13 Fig.
Page 6
Feedback Signal Converter AS List of Figures 10000001298 Edition: 001...
Feedback Signal Converter AS List of Tables List of Tables Tab. 1: Change History............................1 Tab. 2: List of Further Documents......................... 3 Tab. 3: Dimensional Drawings..........................3 Tab. 4: Wiring Drawings............................3 Tab. 5: CAN Bus, Cable Requirements......................... 6 Edition: 001 10000001298...
Page 8
Feedback Signal Converter AS List of Tables 10000001298 Edition: 001...
Feedback Signal Converter AS List of Abbreviations List of Abbreviations ESD Protected Area Electrostatic Discharge Follow-Up ISPC Illustrated Spare Parts Catalog Non-Follow-Up Printed Circuit Board Rudder Angle Indicator Edition: 001 10000001298...
Page 10
Feedback Signal Converter AS List of Abbreviations 10000001298 VIII Edition: 001...
Feedback Signal Converter AS Introduction Introduction Preliminary Remarks The present manual is a description and reference book only. It is intended to answer questions and to solve problems in the quickest possible manner. Read and follow the instructions and notes in this manual before operating the equipment. For this purpose, refer to the table of contents and read the corresponding chapters thoroughly.
Feedback Signal Converter AS Introduction WARNING! Warning statements indicate a hazardous situation that, if not avoided, could result in minor, moderate or serious injury, or death Consequence • Preventive action CAUTION! Caution statements indicate a hazardous situation that, if not avoided, could result in material damage Consequence •...
Feedback Signal Converter AS Introduction Dissipative Shoes Floor Mat Wrist Band Wrist Strap Common Ground Ground Point Any product which is labeled as shown is electrostatic sensitive. If proper Electrostatic Discharge (ESD) precautions are not taken, handling or working on this product results in damage.
Feedback Signal Converter AS 1 Description 1 Description 1.1 Purpose The Feedback Signal Converter AS is a part of the control loop of a steering control system. It provides information about the current position of the rudder. This information is required for follow-up steering, rudder angle indicators, steering failure sensors and adaptive autopilots which are connected to a bus.
Feedback Signal Converter AS 1 Description 1.3 Technical Description 1.3.1 CAN Bus Module Fig. 2: CAN Bus Module, Connections and Indicators Element Remarks Plug B1 Connects CAN bus and supply voltage Plug B2 Development only DIP switch B3 Development only (all switches in position ON - do not use.) Pushbutton B4 Resets CPU Plug B5...
Feedback Signal Converter AS 1 Description For the CAN bus it is essential that every CAN bus participant is addressable via a unique address. This address is set within each CAN bus participant or via a component (participant) which is able to look into the CAN bus architecture. Note The CAN bus address can be set with a special service tool by the service personnel only.
Feedback Signal Converter AS 1 Description Term Designation Capacitance max. 50 pF/m Cable line delay max. 5 ns/m Cable length max. 400 m (termination to termination) 1.4 Functional Description 1.4.1 CAN Bus Module The CAN bus module is set up for potentiometers or contactless sensors. This has to be configured with a Service Tool (Anschütz service personnel only) for the specific application.
Feedback Signal Converter AS 2 Operation 2 Operation 2.1 Preliminary Remarks User Rights The manual is a complete documentation of the system or equipment. Some functions may not be accessible depending on user rights. All functions or operations are described irrespective of the actual user rights of the user. Markup Elements The manual uses different markup elements for hardware and software.
Feedback Signal Converter AS 2 Operation 2.3 Pre-Operation Procedures after Longer Time Setting out of Operation This system or equipment requires no special pre-operation procedures after longer time setting out of operation. 2.4 Operation This equipment is not a stand-alone system. The equipment has no operation elements and is connected to other devices.
Feedback Signal Converter AS 3 Installation and Maintenance 3 Installation and Maintenance 3.1 Safety Instructions for Installation and Maintenance WARNING! Danger due to maintenance and service by unskilled personnel Risk of serious injury and material damage • Keep all unskilled personnel away from the working area. •...
Feedback Signal Converter AS 3 Installation and Maintenance Note All spare parts that are produced by Anschütz GmbH are identified in the ISPC by a seven-digit part number. This part number is included in the serial number on the type plate of the equipment. The first 7 digits of the serial number are formed by the part number.
Feedback Signal Converter AS 3 Installation and Maintenance 3.3.3 Cable Connections 3.3.3.1 General Remarks about Preparing Cable Connections WARNING! Danger due to electrical current Risk of death or serious injury or material damage • Make sure that all cables are disconnected from the power supply. •...
Feedback Signal Converter AS 3 Installation and Maintenance Fig. 5: Prepare a Cable Entry 7. Insert the earthing insert, the seal, and the washer into the cable gland, place the counter nut last and tighten the nut hand-tight. 8. Strip the cable cores to a length of approx. 15 mm, twist slightly and clamp on the cable end sleeves.
Feedback Signal Converter AS 3 Installation and Maintenance 3.3.3.2 General Remarks about Preparing Common Ground Connections In order to comply with the stringent requirements, please follow the instructions given below regarding cable connections. Use the cable types specified. CAUTION! Damage to Equipment and Components It is essential to make sure that any equipment and any additional component (options) have common reference to the ship's common ground.
Feedback Signal Converter AS 3 Installation and Maintenance Fig. 8: CAN Bus Module, Connections Plug / Ter- Remarks minal B1/1 Supply voltage +14 to 36 V DC B1/2 Supply voltage 0 V DC Supply voltage source is connected CAN bus application B1/3 B1/4 Can bus CAN bus termination, see...
Feedback Signal Converter AS 3 Installation and Maintenance 3.4 Care and Maintenance Note The Feedback Signal Converter AS is an important part of the steering control system. Regarding the ship’s safety, particular attention must therefore be paid to its care and maintenance and the use of original Anschütz equipment / parts only.
Feedback Signal Converter AS 4 Transport and Storage 4 Transport and Storage 4.1 Preservation, Packing and Storage Preservation All components / devices require no special preservation procedures. Packing All components / devices are packed with a special protection against humidity. The package contains desiccants and a humidity indicator.
Feedback Signal Converter AS 4 Transport and Storage Color Indication Inside Humidity Necessary Action 40 % patch: pink > 40 % Desiccants must be replaced Components / devices must be checked for hu- midity, 50 % patch: pink > 50 % Desiccants must be replaced, Packaging must be checked for damages Note...
Feedback Signal Converter AS 5 Disposal 5 Disposal The Feedback Signal Converter AS or components of it can be disposed according to the respective national regulations for electronic waste without harmful materials (according to Directive 2012/19/EU on waste electrical and electronic equipment (WEEE)). Edition: 001 10000001298...
Shows installed quantity of the spare part for this unit or subunit (Quantity Installed) Remarks Shows more information about the spare part 6.3 Feedback Signal Converter AS Fig. No. Designation 1. Part No. Remarks Item No. 2. Part No. Feedback Signal Converter AS 4003785 101-533.NG001 10000001298 Edition: 001...