Set the RIT control to O.
Push the RIT
control to turn it on (RIT li-
ght lighted).
If the display frequency changes, adjust the RIT CENTER trim-
pot (R536) on the PTO control board so that
there is no
change in the dis-
play frequency between
RIT
on and
RIT
off.
Verify that the RIT control
varies the frequency of the display
±
SOO to 1500 Hz.
Turn the
PTO A control
fully counterclockwise and
note how much the
display frequency goes below 14000.0 kHz.
Now turn the PTO A control to its
clockwise limit and note
how much the display frequency
goes above 14500.0
kHz.
The amount that the frequency
extends beyond the lower and upper band
limits should be
greater than
50 kHz
and within 10 kHz of each other.
If
this is not the case,
adjust trimmer c606 on PTO A for the proper frequency
range.
Set the PTO MODE switch to PTO Band repeat the above procedures for B.
EXCITER I. F. ADJUSTMENTS
Set the MODE switch to CW,
the PTO MODE switch to PTO A,
the PASSBAND
control to its 12 o'clock position, and adjust PTO A for a display frequency
of 14300.0 kHz.
Conneet the output of the
RF generator to the ANTENNA con-
nector on the rear apron of the unit.
Set the RF generator output for 50 uV
and adjust its frequency for
maximum S meter reading
on the unit.
Adjust
transformers
TlOl, Tl02, Tl03 and TI04 on the exciter board for a maximum S
meter reading.
AGC AND S METER CALIBRATION
--
- - -
---
Use the same test setup
as previous section.
Connect the oscilloscope
probe to the cathode of diode CR123 (AF in line) on the audio board.
Adjust
the
AGC THRESH
trimpot (RlOl) on the audio board for 600 mV p-p indication
on the oscilliscope screen.
Disconneet the oscilloscope probe.
Adjust the S METER CAL trimpot (RIIO) on the audio board for an S
9
in-
dication on the unit's meter.
CWN FILTER ADJUSTMENT
Set the MODE switch to CWN and connect the frequency counter across the
units
speaker terminals, keeping the rest of the test setup the same as for
the previous section.
Adjust PTO A for a 1650 Hz ± 20 Hz speaker audio tone
and adjust CWN trimmer capacitors C130
and C134
on the exciter board for a
maximum S meter reading.
Switch the MODE to CW and verify that the S meter
reading changes by less than one S unit.
NOTCH FILTER ADJUSTMENT
Use the same
test setup as before.
Conneet the AC voltmeter or oscil-
loscope across the speaker terminals.
Adjust PTO A for a
1650 ± 20 Hz tone
in the
speaker.
Adjust the
NOTCH FILT
control for
minimum speaker audio
output,
then adjust the NOTCH FILTER ADJUST trimpot (R17S) on the audio bo-
ard for minimum speaker audio output.
Repeat the
adjustments of NOTCH FILT
and N F ADJ controls until there is no further decrease in the speaker audio
output.
The notch filter should attenuate the speaker audio
by more
than
25 dB.
Verify that speaker audio output can also be attenuated
by
the notch
filter with speaker audio tones of 400 Hz and 2500 Hz.
Disconneet the freq-
S-lO