Download Print this page

MRMC -2127-01 Quick Start Manual

Ethernet trigger relay box

Advertisement

Quick Links

Ethernet
Trigger
Relay Box
Quick Start Guide
QSG Product Code: MRMC-2310-00
Products covered: MRMC-2127-01
CRANES AND RIGS | BROADCAST | HEADS & DSLR | PRODUCT PHOTOGRAPHY | RENTALS

Advertisement

loading
Need help?

Need help?

Do you have a question about the MRMC-2127-01 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MRMC MRMC-2127-01

  • Page 1 Ethernet Trigger Relay Box Quick Start Guide QSG Product Code: MRMC-2310-00 Products covered: MRMC-2127-01 CRANES AND RIGS | BROADCAST | HEADS & DSLR | PRODUCT PHOTOGRAPHY | RENTALS...
  • Page 2 Ethernet Trigger Relay Box Quick Start Guide Products covered: MRMC-2127-01 QSG Product Code: MRMC-2310-00 © 2021 Mark Roberts Motion Control Ltd. All rights reserved. No part of this publication may be reproduced, transmitted, or translated by any means — graphical, electronic, or mechanical — including...
  • Page 3: Table Of Contents

    Ethernet Trigger Relay Box Quick Start Guide Contents Ethernet Trigger Relay Box Model Mover Quick Start Guide Ethernet Trigger Relay Box Quick Start Guide Chapter 1 Quick Start..............1 Overview .................1 Connecting Cables..............1 Using the trigger outputs ............2 Testing the trigger outputs...........3 Using the trigger inputs............3 Testing the trigger inputs..........3 Appendix 1...
  • Page 4 Ethernet Trigger Relay Box Quick Start Guide...
  • Page 5: Chapter 1 Quick Start

    Overview Thank you for using the Ethernet Relay Trigger Box from Mark Roberts Motion Control (MRMC). The purpose of this device is to trigger events on it's eight relays over physical ethernet connection, it also has two inputs. The blue LED is power and green LED signifies that the program running.
  • Page 6: Using The Trigger Outputs

    The external device that is being triggered must provide its own power for the trigger circuit, up to 250 Volts AC or 30 volts DC, 10A maximum; for highly inductive loads current should be limited to 3A. Contact MRMC for further advice on maximum current for triggering external devices.
  • Page 7: Testing The Trigger Outputs

    Ethernet Trigger Relay Box Quick Start Guide Testing the trigger outputs You can test that the Trigger Box is receiving trigger signals from Flair, without needing to attach anything to the OUT connectors on the Trigger Box: In Flair, use menu option Setups ...
  • Page 8 Ethernet Trigger Relay Box Quick Start Guide In Flair, use menu option Setups  Input Triggers. Short the 2 wires connected to the trigger input post. The corresponding numbered Input Trigger State in the pop-up should change from Open to Closed.
  • Page 9: Appendix 1 Specifications

    Ethernet Trigger Relay Box Quick Start Guide Appendix 1 Specifications Ethernet Trigger Relay Box Model Mover Quick Start Guide Ethernet Trigger Relay Box Quick Start Guide Weight: Temperature range: 0-40 °C Humidity tolerance: 0% to 85% relative humidity, non-condensing...
  • Page 10 Ethernet Trigger Relay Box Quick Start Guide Notes...
  • Page 11 Ethernet Trigger Relay Box Quick Start Guide Notes...
  • Page 12 Mark Roberts Motion Control Ltd. Unit 3, South East Studios, Blindley Heath, Surrey RH7 6JP United Kingdom Telephone: +44 (0) 1342 838000 info@mrmoco.com www.mrmoco.com...