WARNING - RISK OF SHOCK
1. This xture is to be installed by only a quali ed electrician.
2. This xture is to be used at 120V AC/60Hz power supply only.
3. This xture is designed for use in a circuit protected by a fuse or circuit breaker.
4. Turn o the power supply at the fuse or circuit breaker box before you install this xture.
5. Turn o the power supply again when you perform maintenance.
6. Double check all connections to be sure they are all tight and correct.
7. Operation environment: to be installed indoors under dry and ventilated environment. It should NOT be installed damp locations or
environment with high temperature. Installation of this xture should be kept away from other electrical devices.
What's In The Box
One (1) Prime Chime Plus
Tools Needed
The Prime Chime Plus requires very few tools for installation. A screwdriver and a pair of wirecutters will be
required to install the chime.
Junction Box
Pre-install a dual voltage box (CARLON Model#SC200DV or equivalent, not provided) before installation of this device.
Video Doorbell Compatibility Notes
For all video doorbells:
1) To ensure proper operation of the PRCP2, no more than one video doorbell should be attached (Front Door or Back Door)
2) Make sure the video doorbell is fully charged prior to installation. Low battery levels may cause abnormal performance of the PRCP2.
3) Wiring must not exceed the following: 70' from doorbell to rst unit. 200' total length if installing more than one PRCP2
4) A "power" or "diode" kit should not be installed when using the NICOR PRCP2. It is designed to provide the proper voltage for
compatible video doorbells.
For Ring products:
Adjust the "Ring tone length" in the App to 2 seconds to avoid multiple chime cycles (see Ring instructions for details).
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com June 30, 2023 5:00 PM PRCP2 Rev - Page 1 of 5
Two (2) Lighted Doorbell Buttons
Prime Chime Plus
Model:
One (1) Hardware Pack
PRCP2
Need help?
Do you have a question about the Prime Chime Plus PRCP2 and is the answer not in the manual?
Questions and answers
Installed new prcp2 and power it up and light does not come on or chime does not work. White to white and black to red wires connected. Did I get a bad one?
The NICOR Prime Chime Plus PRCP2 may not be lighting up or chiming after installation due to the following possible reasons:
1. Power Issue – Ensure that the unit is receiving 120V/60Hz power and that the line voltage wiring (black to black, white to white) is correctly connected.
2. Incorrect Wiring – Verify that the low-voltage bell wires (18ga or 22ga) are connected properly to the FRONT (1+ and 2-) or REAR (3+ and 4-) ports.
3. Faulty Doorbell Button – Check if the button is securely connected using screw terminals and mounted correctly.
4. Overuse of Button – Repeated pressing or holding of the doorbell button may cause product issues.
5. Installation Issues – Ensure the chime is properly mounted in the junction box and the faceplate is securely attached.
6. Power Not Applied – Confirm that power has been turned on after installation and that the button illuminates.
7. External Interference – If other electrical devices are causing interference, it might affect operation.
Testing each step systematically can help identify and resolve the issue.