ALBIN PUMP Marine Defroster 9 kW 6 Outlets Instructions For Use Manual

ALBIN PUMP Marine Defroster 9 kW 6 Outlets Instructions For Use Manual

Hide thumbs Also See for Marine Defroster 9 kW 6 Outlets:

Advertisement

Quick Links

Instruction for use
Original version
Marine Defroster 9 kW 6 Outlets
Instruction for use
Marine Defroster 9 kW 6 Outlets
PRD0395D01en
www.albinpumpmarine.com
1 (16)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Marine Defroster 9 kW 6 Outlets and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ALBIN PUMP Marine Defroster 9 kW 6 Outlets

  • Page 1 Instruction for use Original version Marine Defroster 9 kW 6 Outlets Instruction for use Marine Defroster 9 kW 6 Outlets PRD0395D01en www.albinpumpmarine.com 1 (16)
  • Page 2 Albin Pump Marine defrosters are designed and manufactured to the highest standards of reliability and safety. The content of this manual is in accordance with the design and construction of the equipment at the time of publishing. Albin Pump Marine reserves the right to introduce design modifications without prior notice. PRD0395D01en www.albinpumpmarine.com...
  • Page 3: Table Of Contents

    Instruction for use Original version Marine Defroster 9 kW 6 Outlets Table of Contents Introduction ........................4 1.1. Intended use of product .................... 4 1.2. General description of product ................. 4 1.3. Main function of product ................... 4 Safety information ......................5 2.1.
  • Page 4: Introduction

    Instruction for use Original version Marine Defroster 9 kW 6 Outlets 1. Introduction 1.1. Intended use of product This equipment is intended for use in marine environment, incorporated in marine vessels. The equipment is not designed for use and operation in explosive environments.
  • Page 5: Safety Information

    Instruction for use Original version Marine Defroster 9 kW 6 Outlets 2. Safety information This product must only be operated, maintained and repaired by personnel who have been informed of the residual risks involved in operating it, and who have been warned of the risks involved if not following the instructions in this manual.
  • Page 6: Technical Data

    Instruction for use Original version Marine Defroster 9 kW 6 Outlets 3. Technical data Parameter Value 09-02-017 kit 09-02-018 kit Part number 09-02-015 unit 09-02-016 unit Premium defroster 9 kW Premium defroster 9 kW Description 12V 6 Outlets 24V 6 Outlets...
  • Page 7: Handling

    Instruction for use Original version Marine Defroster 9 kW 6 Outlets 4. Handling Product is packed in carton box and can be handled by any available means, due to its low weight and size. Wear protective gloves to prevent any cuts from possible sharp edges.
  • Page 8: Control Panel

    Instruction for use Original version Marine Defroster 9 kW 6 Outlets Following mounting positions (vertical blower axis) are possible, but not recommended. Product will operate in such position, however longevity of blower will be decreased. 5.2. Control panel Mount control panel in designated place by means of suitable screws or bolts (not included).
  • Page 9: Pinning

    Instruction for use Original version Marine Defroster 9 kW 6 Outlets 5.3.1. Pinning Positions in each connector given in this instruction are matching markings on connectors and related manufacturer’s documentation. Main connector pinning is as follow: 1. High speed 2. Medium speed 3.
  • Page 10: Water Connection

    Instruction for use Original version Marine Defroster 9 kW 6 Outlets 5.4. Water connection Product is connected to water-based system by means of two 5/8” (outer diameter, ≈ 16 mm) copper pipes with beads according to DIN 71550 standard. Water connection Appropriate set of hoses and hose clamps should be used to connect the product to the system.
  • Page 11: Air Connection

    Instruction for use Original version Marine Defroster 9 kW 6 Outlets 5.5. Air connection Securely connect air hoses to plastic hose adapters on both inlet and outlet sides. 6x connection for Φ63,5 mm (2,5”) or Φ60 mm (2,4”) air hoses, air outlet side 2x connection for Φ90 mm (3,5”) air hoses, air inlet side...
  • Page 12: Operation

    Instruction for use Original version Marine Defroster 9 kW 6 Outlets 6. Operation 6.1. Control panel Heater can be run in different blower speeds or turned off completely. Use knob in control panel to set desired blower speed. Possible speeds to select from: •...
  • Page 13: Troubleshooting

    9. Consumables and spare parts Following list of spare parts is suggested by Albin Pump Marine. Albin Pump Marine may not be considered liable of possible damages caused from faulty spare parts, if the spare parts are: ▪ Not supplied by Albin Pump Marine ▪...
  • Page 14: Spare Parts

    Instruction for use Original version Marine Defroster 9 kW 6 Outlets 9.2. Spare parts Following parts are available as spare parts. APM P/N Description Note 09-66-023 Air hose adapter Φ60 mm (2,4”), snap-in 09-66-034 Air hose adapter Φ63,5 mm (2,5”), snap-in 09-66-022 Air hose adapter Φ90 mm (3,5”)
  • Page 15 Instruction for use Original version Marine Defroster 9 kW 6 Outlets PRD0395D01en www.albinpumpmarine.com 15 (16)
  • Page 16 Instruction for use Original version Marine Defroster 9 kW 6 Outlets Albin Pump Marine AB Kämpevägen 17 info@albinpumpmarine.com 55302 Jönköping, Sweden www.albinpumpmarine.com PRD0395D01en www.albinpumpmarine.com 16 (16)