  • Page 1 BA FluidIX LUB-VDT EN Mounting and operating instructions FluidIX LUB-VDT Inline Condition Monitoring Sensor ZILA GmbH Hollandsmühle 1 98544 Zella-Mehlis Deutschland Web: www.zila.de E-Mail: info@zila.de Telefon: +49 (0) 3681 867300 Mounting and operating instructions Version: EN_230424_ANHU_LUB3|...
  • Page 2: Table Of Contents

    Measurement specifications ..4 • Modification and conversion of the device is not 2.2. Mounting instructions ........ 5 permitted and releases ZILA GmbH from any 2.3. Pin assignment .......... 5 warranty and liability data filter ............ 6 Modbus Interface ........6 Read these assembly instructions 4.1.
  • Page 3: Intended Use

    If it becomes obvious that safe operation is no longer possible (e.g. in the case of visible damage), please take The FluidIX LUB-VDT is a compact sensor for monitoring the unit out of operation immediately and secure it mechanical fluid characteristics such as viscosity and against unintentional operation.
  • Page 4: Technical Data

    BA FluidIX LUB-VDT EN 2.1. Technical data 2.1.1. General specifications Dimensions 30x93,4mm Weight 150g Protection class IP68 Material Stainless steel Power consumption 1 W (without analogue outputs) Supply voltage 9…35 V (24V) Screw connection G 3/8“ Tightening torque 31…39 Nm Elec.
  • Page 5: Mounting Instructions

    BA FluidIX LUB-VDT EN 2.2. Mounting instructions Note: Although the sensing element itself is virtually insensitive to pressure, the viscosity of the oil is a The sensing element of the LUB-VDT is a quartz crystal function of pressure. The effects of tuning fork resonator.
  • Page 6: Data Filter

    To provide reliable, low-noise results in applications with lower data rate 4.2. Register Map requirements, the FluidIX LUB-VDT provides a moving average filter for all measured parameters. The length of the filter is configurable via a Modbus register from 1 to...
  • Page 7 BA FluidIX LUB-VDT EN Error Count Counter for measurement error incl. out- of-range: Value is zero at switch-on Measuremen Each measurement is assigned a Note: By default, analogue output 1 t Results sequential number that is reset to 0 at is configured for temperature (-40 ..
  • Page 8: Overview Status Codes

    BA FluidIX LUB-VDT EN 4.3. Overview Status Codes 4.4. Modbus Register Description Causes No resonance Resonance search is detected still in progress, liquid outside measuring range, sensor damaged or dirty Out of range At least one parameter is out of range...