Quick Links

This conversion kit shall be installed by a
qualified service agency in accordance with
the manufacturer's instructions and all
applicable codes and requirements of the
authority having jurisdiction. The information
in these instructions must be followed to
minimize the risk of fire or explosion or to
prevent property damage, personal injury or
death. The qualified service agency is
responsible for the proper installation of this
kit. The installation is not proper and
complete until the operation of the converted
appliance is checked as specified in the
manufacturer's instructions supplied with the
kit.
In Canada:
The conversion shall be carried out in accordance with the requirements of the provincial
authorities having jurisdiction and in accordance with the requirements of the CAN/CSA-B149.1
and CAN/CSA-B149.2 Installation Code.
LA CONVERSION DOIT ÊTRE EFFECTUÉE CONFORMÉMENT AUX EXIGENCES DE L'AUTORITÉ
PROVINCIALE AYANT JURIDICTION ET AUX, CAN/CSA-B149.1, ET CAN/CSA-B149.2.
*A qualified service agency is any individual, firm, corporation or company which either in person or
through a representative is engaged in and is responsible for the connection, utilization, repair or
servicing of gas utilization equipment or accessories; who is experienced in such work, familiar with all
precautions required, and has complied with all of the requirements of the authority having jurisdiction.
*Conversion acceptable for install locations 0-2,000 feet. See unit's installation manual for procedures to
adjust above 2,000 feet.
NORITZ America Corporation
11160 Grace Avenue
Fountain Valley, CA 92708
866-766-7489
www.noritz.com
Installation Guide
Conversion Kits: CK-82, CK-83
Cette trousse de conversion ne doit être
installée que par le représentant d'un
organisme qualifié et conformément aux
instructions du fabricant et à tous les codes et
exigences pertinents de l'autorité
compétente. Les instructions de cette
notice doivent être suivies afin de réduire au
minimum le risque d'incendie ou d'explosion,
de dommage matériel, de blessure ou de
mort. L'organisme qualifié
est responsable de l'installation adequate de
cette trousse. L'installation n'est pas adéquate
ni complète tant que le bon fonctionnement
de l'appareil converti n'a pas été vérifié selon
les instructions du fabricant fournies avec la
trousse.
1
CK-IM-16
Rev. 05/19

Advertisement

Table of Contents
loading

Summary of Contents for Noritz CK-82

  • Page 1 Installation Guide Conversion Kits: CK-82, CK-83 This conversion kit shall be installed by a Cette trousse de conversion ne doit être qualified service agency in accordance with installée que par le représentant d'un the manufacturer’s instructions and all organisme qualifié et conformément aux applicable codes and requirements of the instructions du fabricant et à...
  • Page 2: Safety Symbols

    *The model type can be verified from the rating plate located on the right side of case of the unit. Tools Required: • Noritz Remote Controller (RC-7651M-A or RC-9018M) • Manometer (Capable of displaying digits in tenths (i.e. 2.4) and up to 20” W.C.) •...
  • Page 3: Conversion Procedure

    Sticker (French) NG-Conversion Connector *only in conversion kit CK-82 4. Conversion Procedure Failure to correctly assemble the components according to these instructions may result in a gas leak or explosion, personal injury or death. 1) If the display on the remote controller is on, turn off the unit by pressing the “ON/OFF”...
  • Page 4 6) Remove the 2 screws and the Mounting plate. Remove the C-Clamp -16B. Then remove the 4 screws with a Long Philips screwdriver. (Figure 2) DO NOT use a power drill. 2 screws and the Mounting plate C-Clamp -16B Figure 2 7) Remove the Fan Motor and the Venturi assembly.
  • Page 5 10) Make sure the Gas type, Venturi size, and Injφ on the Venturi label. Label Venturi Model Gas type Injφ φ color EZ111DV (GQ-C3260WX-FF US) White 500/510 (NAT GAS) EZ98DV (GQ-C2860WX-FF US) NCC199CDV(GQ-C3260WZ-FF US) NRCR111DV (GQ-C3260WXQ-FF US) Black 415/410 NRCR92DV (GQ-C2660WXQ-FF US) 11) Replace the O-ring –Venturi to new one.
  • Page 6: Parameter Settings

    5. Parameter Settings < When converting propane to natural gas > 1) Disconnect the electrical power. 2) Find a connector with a NG-conversion tag located at the bottom left of the unit. Connect the NG-conversion connector in the conversion kit. <...
  • Page 7: Trial Operation

    5) Change the Item number “37” from OFF to ON. DO NOT change the other item numbers. This will cause a fault in the unit. 6) After setting the item number “37”, press and hold the “▲” and “▼” buttons together for 5 seconds to complete the new settings.
  • Page 8: Installation Checklist

    7. Installation Checklist Parts Replacement: □ Remove existing Venturi, O-Ring-Venturi, and O-ring-P18. Discard these parts. □ Replace with new Venturi, O-Ring-Venturi, and O-ring-P18. □ Make sure that Venturi, O-Ring-Venturi, and O-ring-P18 are securely in place. Parameter Settings: □ When converting propane to natural gas, connect the NG-conversion connector. □...