Noritz EZ2FVK-2 Installation Manual
Noritz EZ2FVK-2 Installation Manual

Noritz EZ2FVK-2 Installation Manual

Vent kit for condensing tankless gas water heater

Advertisement

Quick Links

Vent Kit for Condensing Tankless Gas Water Heater
Model: EZ2FVK-2 (Flex Vent 2" Kit 35 feet)
Potential dangers from accidents during installation and use are divided into the following three
categories. Closely observe these warnings, they are critical to your safety.
DANGER
WARNING
CAUTION
DANGER:
Never use this Vent Kit other than for the Applicable Model (including the model manufactured by others)
designated in this manual.
WARNING:
If the information in this manual is not followed exactly, a fire or explosion may result causing property
damage, personal injury or death.
Do not install only with the Start-up Guide. Read this manual also before installation.
Prohibited
Requests to Installers
• This manual is for the vent components for the designated tankless water heater. For the installation
of the Tankless Water Heater itself, read the installation manual packed with it.
• In order to install this vent kit correctly, read this installation manual carefully, and follow the installation
instructions.
• Failures and damage caused by erroneous work or work not as instructed in this manual are not
covered by the warranty.
• Check that the installation was done properly in accordance with this installation manual upon
completion.
• After completing installation, place this installation manual in a plastic pouch and attach it to the side
of the water heater, or hand it to the customer to retain for future reference.
Installation must conform with local codes, or in the absence of local codes, the National Fuel Gas Code, ANSI
Z223.1 /NFPA54-latest edition.
The manufacturer reserves the right to discontinue, or change at any time, the designs and/or specifications of its
products without notice.
EZ2FVK-2-LT
Rev. 07/20
Installation Manual
DANGER indicates an imminently hazardous situation which,
if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which,
if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which,
if not avoided, may result in minor or moderate injury.
Be sure to do
CAUTION
1

Advertisement

Table of Contents
loading

Summary of Contents for Noritz EZ2FVK-2

  • Page 1 Installation Manual Vent Kit for Condensing Tankless Gas Water Heater Model: EZ2FVK-2 (Flex Vent 2" Kit 35 feet) Potential dangers from accidents during installation and use are divided into the following three categories. Closely observe these warnings, they are critical to your safety.
  • Page 2: General Information

    1.General Information Property damage, personal injury or death can result if these instructions are not followed. They are a guide for professional installers generally familiar with the installation and maintenance of heating equipment and related vent systems. • Flex Vent 2" Kit is designed only for the installation inside of B-Vent as sleeve. Do not use it for other installation method.
  • Page 3: Included Accessories

    2.Included Accessories The following accessories are included. Check for any missing items before starting installation. Part Shape Q'ty Part Shape Q'ty Flex Feeder Installation Manual (This document) Base Junction Support • Clamp x3 "Step-1" EZTR 35 Feet Base Junction Start Up Guide Adapter Set Top Flex support "Step-2"...
  • Page 4: General Safety

    3.General Safety DANGER Checkup • If similar flexible vent has already been installed, it must be replaced with this designated new Flex Vent Kit. WARNING • Flex Vent 2" Kit is designed only for installation inside of B-Vent wall. Do not use it for other installation method. Also do not use it outdoor.
  • Page 5: Before Installation

    CAUTION Check for any damage to components that may have occurred during transportation before installation. • Consult with the customer regarding the location of installation. • Do not install this Flex Vent 2" Kit in a place where it may be subject to falling objects, such as under shelves. •...
  • Page 6 Mark " " if each Check point Can be installed(OK) Cannot be installed(NG) condition is matched. Round Oval 3.B-Vent shape 4.B-Vent diameter 3" or 4" 5" or larger 5ft or less More than 5 ft 5.Horizontal distance between B-Vent connection from the ceiling and the unit is no more than 5ft.
  • Page 7 Mark " " if each Check point Can be installed(OK) Cannot be installed(NG) condition is matched. 40°F (5°C) or less More than 40°F (5°C) *Refer to page 4 7.Ambient temperature where unit is installed. 40°F (5°C) Cannot access Rain Cap(High Can access Rain Cap pitch etc.) 8.
  • Page 8 5.Sample of the Venting system The pictured image of the system consisted of this Vent Kit and the explanation of the name of the ■ components The image of the Flex Vent 2" Kit system is as listed below. Only when the venting components and the water heater are installed correctly, the customer can use the hot water correctly and safely.
  • Page 9: Installation

    6.Installation In the installation, some work will be done above the roof, extra care and fall protection may be required. Take extra care and responsibility to do the installation as safely as possible. WARNING: • For your safety, do not attempt to work on a rooftop until safety precautions have been identified and taken including without limitation fall protection measures, ladders or stairways, and personal protective equipment(PPE).
  • Page 10 Step Installation Procedure(ex. @Garage) Necessary Tool 1 Remove the B-Vent between bottom of ceiling and tank type water heater. 2 Drain and remove the tank type water heater. 3 Use a measuring tape to measure from the bottom of the "④B-Vent" to the roof termination to get the total length of the vent run.
  • Page 11 Step Installation Procedure(ex. @Garage) Necessary Tool 4 Grab Bag Labeled "Step-1" for this step of the installation. Measure "④B-Vent" Diameter * Installation for 3" or 4" where "④B-Vent" does not come down through the ceiling. Remove the four screws from "⑤A Base Junction Adapter" Phillips Head Place and center "⑤A Base Junction Adapter"...
  • Page 12 Step Installation Procedure(ex. @Garage) Necessary Tool 6 Push the "⑮Flex Feeder" into the tip of the "③Flex Pipe 2"". ③Flex Pipe 2" ⑮Flex Feeder ⑮ Install the " Flex Feeder" always, even in the case of straight B-Vent runs. Be sure to do ⑮...
  • Page 13 Step Installation Procedure(ex. @Garage) Necessary Tool 8 Take extra care to ensure that the "③Flex Pipe 2"" does not slip by checking the mark you made on the "③Flex Pipe 2"". Firmly tighten "③Flex Pipe 2"" with "⑥C. Flex Pipe Clamp", but be careful not to over tighten as it may distort the "③Flex Pipe 2"".
  • Page 14 Step Installation Procedure(ex. @Garage) Necessary Tool 10 Take off the existing rain cap and place it on the area where it does not fall from the rooftop. Wet Towel * Make sure the inside surfaces of the "④B-Vent" are clean to ensure a good seal of the parts in this step.
  • Page 15 Step Installation Procedure(ex. @Garage) Necessary Tool 13 Use a marker to mark the cutting position. Mark PVC Cutter 3 ribs Box Cutter * All cuts must be made at right angle to the pipe. All field cuts must be deburred. * Take precaution not to drop debris into "③Flex Pipe 2"".
  • Page 16 Step Installation Procedure(ex. @Garage) Necessary Tool 15 Grab Bag Labeled "Step-3" and necessary tools for this step of the installation. Mount the water heater at the appropriate height according to the chart below, connect the gas, cold and hot water lines, and drain pipes. Follow the equipment's installation manual on how to set the equipment's clearance from combustibles.
  • Page 17 Step Installation Procedure(ex. @Garage) Necessary Tool 16 Insert "⑧Rigid 45 Elbow Set" to the equipment's vent connector pipe. When inserting "⑧Rigid 45 Elbow Set", there is tension when it passes through the o-ring within the equipment’s vent connector pipe. Continue to insert "⑧Rigid 45 Elbow Set" until it is firmly seated all the way into the base of the vent connector pipe.
  • Page 18 Step Installation Procedure(ex. @Garage) Necessary Tool [Point] When performing the final cut, make the first cut of the "③Flex Pipe 2"" longer to avoid cutting the "③Flex Pipe 2"" too short. It is easy to determine the length by following the [Point] below and matching the dimension using the below figure. [Point] When determining the cut length, take note on the 2 points listed below.
  • Page 19 Step Installation Procedure(ex. @Garage) Necessary Tool 18 Pull "⑦Flex Sleeve" over "③Flex Pipe 2"" under the ceiling. Then, push into the bottom of "⑥Base Junction Support". And check that "③Flex Pipe 2"" is sticking out from "⑦Flex Sleeve". (If it is not sticking out,cut "⑦Flex Sleeve" until "③Flex Pipe 2"" sticks out.) ⑦Flex Sleeve [Point] "③Flex Pipe 2""...
  • Page 20 Step Installation Procedure(ex. @Garage) Necessary Tool 20 See below chart and set "⑩Coupler O-Ring" and "⑨Coupler Retainer" onto the tip of "③Flex Pipe" in the correct direction. ⑨Coupler Retainer ⑩Coupler O-Ring [Point] Correct way of setting "⑩Coupler O-Ring" and "⑨Coupler Retainer". 21 Pull out assembled "⑧Rigid 45 Elbow Set", which are tentatively locked to the equipment's vent connector pipe.
  • Page 21 Step Installation Procedure(ex. @Garage) Necessary Tool 22 Attach "⑧Rigid 45 Elbow Set" assembly back onto the unit and secure. When inserting "⑧Rigid 45 Elbow Set", there is tension when it passes through the o-ring within the equipment’s vent connector pipe. Continue to insert "⑧Rigid 45 Elbow Set" until it Flat head reaches the all the way to the base of the equipment vent connector pipe.
  • Page 22: Maintenance

    Step Installation Procedure(ex. @Garage) Necessary Tool 26 Extend the lower end of "⑦Flex Sleeve" to the sleeve clamp connector of the upper portion of equipment. Then secure with "2×⑪Fastening Screws", and apply "⑬Aluminum tape" covering the connecting part. Make sure that it is firmly fixed by pulling by hand. * Do not stretch the "⑦Flex Sleeve"...
  • Page 23: Parts Lists

    8.Parts Lists Parts name Shape Part# Flex Vent 2" Kit 35 Feet EZ2FVK-2 ① Universal Rain Cap EZ2FVURC-1 ② Top Flex Support for EZ2FVK EZ2FVK-TFS ③ Flex Pipe 2" EZ2FVP35 ⑤ Base Junction Adapter Set EZ2FVBJADS-1 ⑥ Base Junction Support (w/o hole) EZ2FVBJS-1 ⑦...
  • Page 24 Flex Vent O-Ring Lubricant EZFVL ⑮ Flex Vent 2" Feeder EZ2FVF Flex Vent 2" Kit 35 Feet EZ2FVK-2-LT Installation Manual EZTR 35 Feet Start Up Guide EZ2FVK-2-SUG Packing box EZ2FVK35BOX * "No." indicated on this page corresponds to the number on the applicable component on page 8.