Hoymiles HRSD-2C Quick Installation Manual

Hide thumbs Also See for HRSD-2C:

Advertisement

Available languages

Available languages

Quick Links

WARNING
· Installation MUST comply with local regulations and technical rules.
· Professionals installing HRSD-2C must be qualified, trained and skilled, and shall strictly adhere to this Guide during installation, operation and maintenance.
· The Transmitter must be powered off during HRSD-2C installation.
NOTICE
· Do not mix DC connectors from different manufacturers. Damages caused by it will void the Hoymiles warranty.
· Improper installation may lead to HRSD-2C damage, which is not covered under warranty.
1. Appearance
5
Input 1 +
1
Input 1
2
Input 2
3
Input 2
4
Output
5
Output
6
NOTICE
·
Maintain a minimum of 1.5 cm (0.59 inch) clearance distance between the roof
and the HRSD-2C enclosure to ensure ventilation and heat dissipation.
·
Avoid exposing the HRSD-2C and its DC connectors to sunlight, rain, or snow.
Don't place them between PV modules due to potential gaps.
3. Wiring
A) Connect the PV modules to the HRSD-2C.
1
+
IP68 / NEMA6P
IN 1
IN 2
*
For detailed cable length and wiring instructions, consult the user manual's relevant section.
WARNING
· To disconnect the HRSD-2C, remove the output cables of the HRSD string first, and then disconnect the input cables from the PV modules.
· If you are connecting the HRSD-2C to one PV module, connect Input 1 first, and then short jump Input 2 - and Input 2 + together.
NOTICE
· HRSD-2C output voltage is 0.9 V to 1.1 V when Transmitter "permission to operate" signal is not present.
· Max. cable length from inverter (+) to inverter (-): 2625 ft. (800 m)
· Max. number of strings recommended: 30 modules*
*Source: SunSpec RapidShutdown Specification. Please refer to local regulations before installation.
警告
· 安装工作必须符合当地法规和技术规范。
· 负责安装 HRSD-2C 的技术人员, 须具备相应资质、 接受过相关培训且掌握相关技能, 在安装、 操作与维护时应严格遵照本指南。
· 安装 HRSD-2C 过程中, 发射机电源必须处于断开状态。
注意
·
请勿将不同制造商品牌的直流连接器配套使用, 若因此造成 HRSD-2C 损坏或产生任何问题, 禾迈概不质保。
·
未按本指南中的正确顺序执行安装步骤可能导致 HRSD-2C 损坏, 如有损坏, 禾迈概不质保。
1. 产品外观
5
输入端 1 正极端口
1
输入端 1 负极端口
2
输入端 2 正极端口
3
输入端 2 负极端口
4
输出端正极端口
5
输出端负极端口
6
注意
HRSD-2C 的外壳与屋顶之间应至少留有 1.5 厘米空隙, 以确保通风顺畅、 散热充分。
·
请勿将 HRSD-2C 及其直流连接器暴露于阳光雨雪或组件缝隙。
·
Region: Global
AP040902
V1.1
IP68 / NEMA6P
IN 1
IN 2
-
+
-
+
-
1
2
3
4
2
-
+
IP68 / NEMA6P
IN 1
IN 2
HRSD inputs
PV module
outputs
IP68 / NEMA6P
IN 1
IN 2
1
2
3
4
2. Installation
6
B) Connect the outputs of HRSD-2C in series.
3
-
Click !
2. 安装方式
6
HRSD-2C Quick Installation Guide
Mounting Brackets
-40℃ to 85℃
IP68 / NEMA6P
IN 1
IN 2
IP68 / NEMA6P
IN 1
IN 2
HRSD-2C 快速安装指南
安装卡扣
-40℃ ~ 85℃
IP68 / NEMA6P
IN 1
IN 2
© 2023 Hoymiles Power Electronics Inc. All rights reserved.
push
≥15 mm
(0.59 inch)
IP68 / NEMA6P
IN 1
IN 2
User Manual Download
向上推
≥15mm

Advertisement

loading
Need help?

Need help?

Do you have a question about the HRSD-2C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hoymiles HRSD-2C

  • Page 1 · To disconnect the HRSD-2C, remove the output cables of the HRSD string first, and then disconnect the input cables from the PV modules. · If you are connecting the HRSD-2C to one PV module, connect Input 1 first, and then short jump Input 2 - and Input 2 + together.
  • Page 2 คํ า เตื อ น · หากต้ อ งการยกเลิ ก การเชื ่ อ มต่ อ HRSD-2C ให้ ถ อดสายเคเบิ ล เอาท์ พ ุ ต ของสตริ ง HRSD ออกก่ อ น จากนั ้ น จึ ง ถอดสายเคเบิ ล อิ น พุ ต ออกจากโมดู ล PV ·...