2-wire track, with YD7403 booster viaLocoNet®……………………………8 Connec on example of the YD6016LN-CS feedback unit on the 2-wire track, with YD7403 booster, Z21® via Roco® B-Bus®…………. 9 Connec on example YD7403 booster, feedback on 2-wire track via the CDE booster connec on e.g. Lenz® LZxxx…………………………………….. 10 Connec on example YD7403 booster, feedback on 2-wire track via the track sniffer input…………….…………………………………………………………..
A en on! The digital formats mfx®, Motorola and similar are not supported! The YD7403 is a pure DCC booster. The YD7403 is configured "out of the box" so that the signal source (Loconet®, B-Bus®, CDE connec on, track sniffer) is selected automa cally.
YD7403 Technical Data Load capacity Track Out 3,5A Dimensional Drawing Loconet® B, Roco® B-Bus, 94,5 mm Connec on op ons CDE Booster Anschluss, Track Sniffer 84 mm 84 mm x 88 mm x 22 mm Housing Dimensions 94,5 mm, 42,5 mm...
A Loconet® connec on cable can be used to establish a connec on Connec on 2 to the control centre via Loconet® B. ES-PGM YaMoRC programming adapter connec on Link Firmware updates and advanced programming can be carried out with the YaMoRC programming adapter.
Page 7
YD7403 Hardwareübersicht 13 Booster bu>on Various ac ons can be triggered with this buGon. By default, the ac on Power on/off is global (switch the control centre and all boosters on or off) Orange LED Indicates that data is being exchanged via Loconet®.
YD7403 Connec on example of the YD6016LN-CS feedback unit on the 2-wire track, with YD7403 booster via LocoNet® Con nue LocoNet® Components Track separa on on both sides between control centre and booster Booster Zentrale Note: Always check the track separa on between the control centre and boos- ter as shown here! The measured value displayed must not exceed 0.8...
* Galvanic isola on of the Loconet® in the YD7403 means that the YD7403 can be safely connected to the Loconet® of the Z21 via Loconet®. This makes it possible to control the YD7403 and query status messages via Loconet®.
A>en on! Only the connec on via the CDE terminals of the control centre to the YD7403 is shown here. The YD6016LN-CS only serve as an example of how the connec on to the track can look.
A>en on! Only the connec on via the track out terminals of the control centre and the track sniffer input of the YD7403 is shown here. The YD6016LN-CS only serve as an example of how the connec on to the track can look.
YD7403 Connec on example of the YD7403 booster to an Uhlenbrock® Intellibox®, Intellibox®2 or Intellibox® Basic Con nue LocoNet® Components Intellibox®/IR Intellibox® Basic Loconet® Track Intellibox® 2 A>en on! The track output (Track Out) of the Intellibox® must not be connected to the same circuit as the boosters.
Content of the guarantee/exclusions: The warranty includes, at YaMoRC's discre on, the free repair or free replacement of the defec ve part, which can be proven to be due to design, manufacturing, material or transport faults. For this purpose, you must send the decoder to us properly stamped. Further claims are excluded.