Do you have a question about the Silence A100 and is the answer not in the manual?
Questions and answers
ABDELMAJID DALLAHI
August 7, 2025
Good morning,
Please inform me about the availability of the vacuum pump of the Cam-100 machine.
Ref: CINDERSON (60-40-07-350-Y-A-V09-GET).
Thank you for your support
E. Taylor Meiser Jr
July 22, 2025
I need replacement part O-type hood for Komax free-100 mini - how to order?
Summary of Contents for Komax Silence A100
Page 1
Dental Aerosol Suction Extractor User’s Manual - The illustrations in this manual are intended for illustration only and may differ from the actual appearance. - The appearance, color, and specifications of the product are subject to change without prior notice for quality improvement - After reading, keep it in a place that is always visible to the person using it.
03 Information for operators The following information is intended to assist you, the operator, in safely working with the Silence Aerosol suction device in your place. Using these operating instructions as a starting point, instruct all operators of the unit with regard to the area of application, the possible hazards during operation, and the proper operation of the dust extractor.
Page 5
03 Information for operators Hazard and Warning Information Only intended for indoor use. The unit is only designed for dry applications and may not be operated or stored outdoors or under wet conditions. The Silence Aerosol suctions are an electric device and, a such, carries with it a certain inherent potential hazard. The unit may not be taken into service until any enquired alterations to comply with regionally specific power plug configurations have been made.
Page 6
Only spare parts and accessories supplied or authorized by by Komax Co., Ltd. department or Komax Co., Ltd. authorized service technician may be used with this product. If other spare parts or accessories are used, this could have a detrimental effect on the safety of the device, increase the risk of serious injury and lead to damage to the environment or the device itself.
Page 7
• The product is altered in any way other than those alterations described in the operating instructions; • The product is repaired by other than an authorized facility or if any but Komax Co., Ltd. OEM parts are employed; • The product continues to be employed, despite obvious safety faults or damage;...
04 Product description Front appearance - A type Arm Screw 3 Joint Arm Clear Hood Fixed Post Main Handle Touchpad Rotaing Post Body Medical Caster Back appearance - A type ※ Can change options for external exhaust Indoor vantilation Circuit breaker Power plug socket Foot switch socket ※...
Page 9
04 Product description Front appearance - H type Multi-joint hose Main Handle Touchpad Body Medical Caster Back appearance - H type ※ Can change options for external exhaust Indoor vantilation Circuit breaker Power plug socket Foot switch socket ※ Foot pedal must be purchased separately when ordering 9 9 9...
05 Product Standard Components Silence-A100 & Silence-H100 Filters 1st Filter 2nd Filter 4th Filter Medium filter ULPA filter Membrane filter (82mm) [99.9995%] ※ The 1st filter replacement notification informs you when to replace by measuring the pressure in the suction part by the pneumatic sensor. Also, the replacement cycle of the filter may vary depending on the usage.
Page 11
05 Product Standard Components Silence-A200 & Silence-H200 Filters 1st Filter 2nd Filter 3rd Filter 4th Filter Medium filter ULPA filter Carbon filter Membrane filter (149mm) [99.9995%] ※ The 1st filter replacement notification informs you when to replace by measuring the pressure in the suction part by the pneumatic sensor.
06 Optional Components Optional Components Filter Premium hoods Hood Medium filter Hood caps (82mm) O type O Cap L type L Cap Medium filter (149mm) U type U Cap 3 Joint Arm ULPA filter Suction motor [99.9995%] ★Silence A type Carbon filter Brush Motor Multi-joint hose...
Page 13
06 Optional Components Touchpad Caster Sterilizer UVC LED lamp Plasma Ionizer Touch display Caster with stopper Arm post Exhaust Plate Main PCB Indoor Rotating post exhaust Touch PCB Outdoor Fixed post exhaust Brushless Motor PCB ★Silence A type Power plug Remote controller Foot switch ※Purchase separately...
07 Appliance usage Touchpad - The Silence Extractors Suction Power Sterilizer RESET ① POWER : Power ON/OFF : other buttons operate when Power ON When the power is on, the ⑦ lamp lights up. ② SUCTION : Suction ON/OFF . When suction works, ⑧ lamp is on. ③...
08 Assemble Setting Silence Extraoral Suction – Silence A 1.Insert the rotating post into the end of the silence joint. 2. Insert the end of the rotating post into the fixed post on the body. Silence Arm can be rotating 360 360 degree rotation Hood Mounting Method...
Page 16
08 Assemble Setting Silence Extraoral Suction – Silence H 1. Insert the end of the Multi-joint hose into the filter cover. Hood Mounting Method 1. Screw the hood O cap onto the end of the Suction hose. 2. Each hood is completed by assembling the L cap and U cap in the same way as in step 1.
③ Carefully lay the body on the floor replace it with a new one. ④ Open the filter lid at the bottom. ※Silence A100&H100 model ⑤ Replace the filter. does not have 3rd filter. Brushless Motor Type, there is no 4th filter.
11 Cleaning & Maintenance Filter cleaning In order to ensure maximum suction performance, it informs you when to change the filter for the filter unit. The following cleaning procedure is carried out. • When the dust collection performance is insufficient (when the suction speed drops below the specified level). •...
Page 20
11 Cleaning & Maintenance Parts list You can check the basic product parts list and the separately purchased parts list. Components (consumables or parts that are worn or damaged) that are not covered by the product warranty are listed in the separately purchased parts list. The serial number, manufacturing month and device specifications are indicated on a sticker on the back of the device.
► The product is altered in any way other than those alterations described in the operating instructions. ► The product is not repaired by an authorized facility or if non-original KOMAX parts are implemented. ► The product continues to be used despite obvious safety faults or damage.
13 Error List Error List Errors Causes Corrective Action Since the temperature of the power line is •When the contact is shorted due overheated, press the circuit breaker switch to the external circuit breaker after cooling the device sufficiently. If you If the power does operation press this switch when the device is not cool...
Need help?
Do you have a question about the Silence A100 and is the answer not in the manual?
Questions and answers
Good morning, Please inform me about the availability of the vacuum pump of the Cam-100 machine. Ref: CINDERSON (60-40-07-350-Y-A-V09-GET). Thank you for your support
I need replacement part O-type hood for Komax free-100 mini - how to order?