Page 1
APL-output wiring Operation manual AES/EBU 1-2 Analog 1 Analog 2 Analog 3 Analog 4 Bi-amp 1+2 Bi-amp 3+4 PUSH PUSH PUSH PUSH PUSH 1+/- 1+/- 1+/- 1+/- 1+/- 1+/- LINK LINK LINK 2+/- 2+/- 2+/- 2+/- 2+/- 2+/- AES/EBU 1-2 Analog 1 Analog 2 Analog 3 Analog 4...
Page 2
If you lend your product to another party, inform that party of the safety-related operating pro- cedures and hand over this assembly guide. If you require additional copies of this manual, you can obtain them free of charge from TW AUDiO or download them from www.twaudio.de Instructions in this user manual...
Page 3
TWAMBO reserves the right to update this document based on recent developments. TWAMBO GmbH Karl-Hofer-Str. 42 14163 Berlin Germany Phone : + 49 (0) 71 41-48 89 89 0 Fax: + 49 (0) 71 41-48 89 89 99 E-Mail: info@twaudio.de WWW: www.twaudio.de...
Operation manual APL-output wiring 1. Safety | Intended use Please adhere to the following safety instructions to avoid risks when using accessories. The APL connection panels are developed for use in professional sound systems. The connection panels may only be used by trained and qualified personnel. Note the operating modes described in this operating manual.
2+/- 2+/- 2+/- 2+/- 2+/- 2+/- Figure: 2.1.1 - APL5-L Usage SYSRACK-L for front mounting in Rack3L | in combination with a power amplifier of the Application Lab Gruppen PLM+ series, PLM+12K44 as standard Dimensions 19“ | 1 U 1× AES/EBU IN + LINK with switchable termination | Input 4×...
Page 7
Operation manual APL-output wiring The APL5-L and APL5-T connection panels are shown in abbreviated form in the following sections. The internal wiring of the outputs of both panels is equivalent, which is why only one representative example is shown. Bi-amp 1+2 Bi-amp 3+4 1+/- 1+/-...
Operation manual APL-output wiring 3. Commissioning The following abbreviations are used in this document: Channel Full range / Broadband / Entire playback spectrum Front speaker, a forward-facing speaker in a cardioid configuration Gradient front, a forward-facing speaker in a cardioid configuration Gradient rear, a rear-facing speaker in a cardioid configuration High frequency / high-frequency spectrum Low frequency / low-frequency spectrum...
Operation manual APL-output wiring Some products offer a passive and a biamp operating mode, e.g. T24N, C12, C15, VERA10. To avoid damage, be sure to load the correct preset for the operating mode in use! NOTE The B10 and B15 loudspeakers have the option of an internal crossover to separate the high and low frequencies.
Page 13
Operation manual APL-output wiring Amplifier configuration of the example system: T24N pa BS30 If you use the BIAMP output of the amplifier or the patch panel, an additional pin reverse cable may be required. NOTE...
Operation manual APL-output wiring Cabling two-channel, passive loudspeaker (biamp) The loudspeaker requires two amplifier channels. The treble drivers of two-channel biamp tops are electrically connected to pin 1+/- and the bass or mid-range drivers to pin 2+/-. When using two-channel biamp tops, always ensure that you use the speakON® connector of one of the biamp outputs on the connection panel.
Page 15
Operation manual APL-output wiring 1+/- 1+/- 1+/- 1+/- 1+/- 1+/- 2+/- 2+/- 2+/- 2+/- 2+/- 2+/- Bi-amp 1+2 Bi-amp 3+4 1+/- 2+/- Multi OUT Mains IN 3+/- 4+/- subwoofer with directional dispersion biamp top GR: CH1 — Pin 1+/- HF: CH1 — Pin 1+/- GF: CH2 —...
Operation manual APL-output wiring Cabling of one- and two-channel passive systems Two-channel passive systems consist of a single-channel passive top and single-channel sub- woofer on each side, driven by two dedicated amplifier channels. Therefore, four amplifier channels are required for the overall L/R system. As single-channel passive tops are electrically connected to pin 1+/-, it is recommended to load these presets into odd-numbered amplifier channels.
Page 17
Operation manual APL-output wiring Single-channel passive systems consist of a top unit and a subwoofer whose frequency ran- ges are separated by an internal passive crossover, usually in the subwoofer. This means that two amplifier channels are required for the overall L/R system. Bi-amp 1+2 Bi-amp 3+4 1+/-...
Operation manual APL-output wiring Cabling two-channel subwoofer configuration When using a speaker configuration for directional subwoofer arrangements (cardioid sta- cks), two independent amplifier channels are required. The APL7 connection panels offer two options for cabling the configurations. Presets for rear-facing subwoofers in cardioid stacks are labeled GR in the system con- troller, and presets for front-facing subwoofers are labeled GF.
Page 19
Operation manual APL-output wiring Amplifier configuration of the example system: BS30cardio_GR BS30cardio_GF BS18cardio_GR BS18cardio_GF 1+/- 1+/- 1+/- 1+/- 1+/- 1+/- 2+/- 2+/- 2+/- 2+/- 2+/- 2+/- Bi-amp 1+2 Bi-amp 3+4 1+/- 2+/- Multi OUT Mains IN 3+/- 4+/- CSA-Stack B18: CSA-Stack B30: GR: CH3 —...
Operation manual APL-output wiring Amplifier system configuration with two-channel passive subwoofer A four-channel overall system can also be realized with a two-channel subwoofer. To do this, the subwoofers are connected in parallel to two amplifier channels. The single-channel, pas- sive tops each use one amplifier channel. 1+/- 1+/- 1+/-...
Operation manual APL-output wiring 5. Transport and Storage Ensure that the surface of the connection panels are not damaged during transport and storage. Moisture may penetrate where steel surfaces are exposed by scratches and result in corrosion. NOTE This is why the products should be transported in a safe, careful, dry and largely dust-free manner.
Operation manual APL-output wiring 6. CE Conformity Declaration Copy and translation of the original CE Conformity Declaration: We hereby declare that the below-referenced components by virtue of their design and con- struction, and in the configuration placed on the market by us, satisfy the safety and health requirements of the applicable EC directives.
Operation manual APL-output wiring 7. Disposal It is prohibited to dispose of used electrical equipment with household refuse. All TWAMBO GmbH products are so-called B2B-products. This means that they are sold by a commercial business to a commercial business. TWAMBO products that bear the trash can symbol shown here may only be disposed of by TWAMBO.
Need help?
Do you have a question about the SYSRACK-L and is the answer not in the manual?