AEMC 275HVD User Manual

Non-contact high voltage detector
Hide thumbs Also See for 275HVD:

Advertisement

Available languages

Available languages

Quick Links

User Manual
Manual de Usuario
ENGLISH
ESPAÑOL
Non-Contact High Voltage Detector
Model 275HVD
Detector de Alta Tensión Sin Contacto
Modelo 275HVD
HIGH VOLTAGE DETECTOR
DECTOR DE ALTA TENSIÓN
WITH AEMC
INSTRUMENTS
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 275HVD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AEMC 275HVD

  • Page 1 User Manual Manual de Usuario ENGLISH ESPAÑOL Non-Contact High Voltage Detector Model 275HVD Detector de Alta Tensión Sin Contacto Modelo 275HVD HIGH VOLTAGE DETECTOR DECTOR DE ALTA TENSIÓN WITH AEMC INSTRUMENTS ®...
  • Page 2 Copyright Chauvin Arnoux , Inc. d.b.a. AEMC Instruments. All rights reserved. © ® ® No part of this documentation may be reproduced in any form or by any means (including electronic storage and retrieval or translation into any other language) without prior agreement and written consent from Chauvin Arnoux , Inc., as governed by United States and International copyright laws.
  • Page 3 Copyright Chauvin Arnoux , Inc. d.b.a. AEMC Instruments. Todos los derechos reservados. © ® ® Prohibida la reproducción total o parcial de este documento de cualquier forma o medio (incluyendo almacenamiento y recuperación digitales y traducción a otro idioma) sin acuerdo y consentimiento escrito de Chauvin Arnoux , Inc., según las leyes de derechos de autor de Estados Unidos e...
  • Page 4 Statement of Compliance Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® certifies that this instrument has been calibrated using standards and instruments traceable to international standards. We guarantee that at the time of shipping your instrument has met the instrument’s published specifications.
  • Page 5 Certificado de Conformidad Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® certifica que este instrumento ha sido calibrado utilizando estándares e instrumentos trazables de acuerdo con estándares internacionales. AEMC Instruments garantiza el cumplimiento de ® las especificaciones publicadas al momento del envío del instrumento.
  • Page 6: Table Of Contents

    TABLE OF CONTENTS 1. INTRODUCTION ..............8 1.1 TESTING THE 275HVD BEFORE OPERATING ..... 8 1.2 PRECAUTIONS FOR USE ..........9 1.3 INTERNATIONAL ELECTRICAL SYMBOLS ......10 1.4 RECEIVING YOUR SHIPMENT ..........10 1.5 ORDERING INFORMATION ........... 10 1.5.1 Accessories ..............10 2.
  • Page 7 TABLA DE CONTENIDOS 1. INTRODUCCIÓN ...............24 1.1 CÓMO VERIFICAR EL DETECTOR DE ALTA TENSIÓN MODELO 275HVD ANTES DE SU USO ........24 1.2 PRECAUCIONES DE USO ..........25 1.4 RECEPCIÓN DE SU EMBARQUE ......... 26 1.5 INFORMACIÓN PARA PONER UNA ORDEN ...... 26 1.5.1 Accesorios y Piezas de Repuesto ........
  • Page 8: Introduction

    Switch the sensitivity to TEST. The warning buzzer should emit A continuous audible tone and the warning light LEDs should stay lit up with the 275HVD in all positions. This indicates that the sensor is operational and the battery functional.
  • Page 9: Precautions For Use

    However, no design can completely protect against incorrect use. The 275HVD should be used by trained and qualified personnel only. The 275HVD can only be used with an insulated rod or Hot Stick rated at the appropriate working voltage. The 275HVD Non-Contact High Voltage Detector is never to be put into direct contact with a live conductor.
  • Page 10: International Electrical Symbols

    Do not use an instrument that appears to be damaged. 1.5 ORDERING INFORMATION Non-Contact High Voltage Detector Model 275HVD ....Cat. #2131.12 Includes three 1.5 V C-cell batteries, shotgun adapter, carrying case, and user manual.
  • Page 11: Product Features

    It also has an auto-test setting to check functionality (see § 4.3). The 275HVD is battery powered and contains three standard 1.5 V C cells in the shaft below the sensing head.
  • Page 12: Typical Uses (Always Use A Hot Stick)

    The 275HVD may not detect, as expected, an electrical field on shielded cables (buried cables are often shielded) or shielded samples and the 275HVD has lower sensitivity on cables with concentric neutrals.
  • Page 13: 275Hvd Features

    240 V - 2 kV - 6 kV - 11 kV - 22 kV - 33 kV - 132 kV - 275 kV ƒ 4. Battery Holder 5. Shotgun adapter end fitting for Hot Stick connection Non-Contact, High Voltage Detector Model 275HVD - User Manual...
  • Page 14: Specifications

    Storage Temperature: (-4 to 150) °F (-20 to 65) °C Humidity: (0 to 93) % RH @ 104 °F (40 °C) Cold Temperature: IEC 68-2-1 Dry Heat: IEC 68-2-2 Damp Heat: IEC 68-2-3 Non-Contact, High Voltage Detector Model 275HVD - User Manua...
  • Page 15: Detection Levels

    As a general rule, in a clean environment, the 275HVD will trigger @ (45 to 65) % of the voltage range at 4 in/10 cm, and detected the selected voltage setting at (8 to 12) in (20 to 30) cm.
  • Page 16 DISTANCE 11 kV 22 kV 13 in - 35 cm 11 kV 33 kV 16 in - 42 cm SETTING VOLTAGE DISTANCE 22 kV 33 kV 14 in - 36 cm Non-Contact, High Voltage Detector Model 275HVD - User Manua...
  • Page 17: Operation

    Switch the sensitivity to TEST. The warning buzzer should emit a continuous audible tone and the warning light LEDs should light up. This indicates that the sensor is operational and the battery functional. Perform the following steps to ensure that the 275HVD detects voltage on a known live conductor. ■...
  • Page 18: High Voltage Testing

    The user may also consider using lower settings to check for lower voltages on a conductor. With the 275HVD at the end of a hot stick, move towards the live conductor until its warnings are triggered.
  • Page 19: Low Voltage Testing

    See Warnings on pages 11 and 12 The 275HVD Non-Contact High Voltage Detector works by proximity. The 275HVD is not designed to be in physical contact with live conductors. Its sensor detects the radiated field that surrounds live conductors. WARNING: Do not touch live conductors with the 275HVD Non-Contact High Voltage Detector.
  • Page 20: Maintenance

    Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® Phone: (800) 343-1391 (Ext. 351) Fax: (603) 742-2346 E-mail: techsupport@aemc.com www.aemc.com Non-Contact, High Voltage Detector Model 275HVD - User Manua...
  • Page 21: Limited Warranty

    (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 E-mail: repair@aemc.com Caution: To protect yourself against in-transit loss, we recommend that you insure your returned material. NOTE: You must obtain a CSA# before returning any instrument. Non-Contact, High Voltage Detector Model 275HVD - User Manual...
  • Page 22 NOTES:...
  • Page 23 NOTES:...
  • Page 24: Introducción

    Seleccione TEST. La señal acústica de precaución emitirá un sonido continuo y audible y la luz de advertencia de la pantalla LED permanecerá encendida en todas las selecciones del modelo 275HVD. Esto indica que tanto el sensor como la batería se encuentran en perfecto estado de operabilidad.
  • Page 25: Precauciones De Uso

    El Detector de Alta Tensión Sin Contacto Modelo 275HVD ha sido diseñado teniendo en mente la seguridad. Sin embargo, ningún diseño puede dar protección total frente a un mal uso. El 275HVD debe ser usado solamente por personal entrenado y calificado. El 275HVD puede ser usado solamente con una pértiga aislada o Hot Stick adecuada a la tensión de trabajo.
  • Page 26: Recepción De Su Embarque

    Reemplazo - Compartimento de baterías con junta tórica y resorte para el modelo 275HVD ..............Cat. #5100.03 Reemplazo - Adaptador d emetal universal para pértiga (hot stick) para el modelo 275HVD ..............Cat. #5100.08 Detector de Alta Tensión Sin Contacto Modelo 275HVD - Manual de Usuario...
  • Page 27: Características Del Producto

    También tiene una posición de auto prueba para comprobar su funcionamiento (ver § 4.2). El 275HVD es operado por baterías y contiene tres baterías tipo C de 1,5 V en el mango bajo la cabeza sensora.
  • Page 28: Usos Típicos (Utilice Siempre Una Pértiga)

    275HVD tiene una sensibilidad menor frente a cables con neutros concéntricos. No se recomienda el uso del 275HVD en en cables o muestras blindadas. Tenga mucho cuidado con cables con neutros concéntricos (utilice un ajuste bajo).
  • Page 29: Características

    240 V - 2 kV - 6 kV - 11 kV - 22 kV - 33 kV - 132 kV - 275 kV ƒ 4. Compartimento de baterías 5. Ranura universal para acople de pértigas Detector de Alta Tensión Sin Contacto Modelo 275HVD - Manual de Usuario...
  • Page 30: Especificaciones

    Temperatura de almacenaje: (-20 a 65) °C (-4 a 150) °F Humedad: (0 a 93) % HR en 40 °C (104 °F) Temperatura fría: IEC 68-2-1 Calor seco: IEC 68-2-2 Calor húmedo: IEC 68-2-3 Detector de Alta Tensión Sin Contacto Modelo 275HVD - Manual de Usuario...
  • Page 31: Niveles De Detección

    Como regla general, en un entorno limpio, el 275HVD se disparará con un (45 - 65) % del rango de tensión a una distancia de 4 in/10 cm y detectará la tensión seleccionada a una distancia de (8 a 12) in (20 a 30) cm.
  • Page 32 22 kV 35 cm - 13 pulg. 11 kV 33 kV 42 cm - 16 pulg. RANGO TENSIÓN DISTANCIA 22 kV 33 kV 36 cm - 14 pulg. Detector de Alta Tensión Sin Contacto Modelo 275HVD - Manual de Usuario...
  • Page 33: Operación

    El 275HVD puede tomar campos eléctricos de circuitos adyacentes al circuito que se está probando y puede dar una información errónea al usuario. ■ La sensibilidad al campo eléctrico se reduce cuando en 275HVD se usa cerca de puntos de tierra. ■...
  • Page 34: Revisión Del 275Hvd

    LED debe encenderse. Esto indica que el sensor está operando y la batería está funcionando. Realice los pasos siguientes para asegurar que el 275HVD detecta la tensión sobre un conductor que se sabe que está energizado.
  • Page 35: Prueba De Baja Tensión

    Con el 275HVD puesto en el extremo de una pértiga, acérquelo al conductoren- ergizadohasta que se disparen las señales de advertencia. 4.5 PRUEBA DE BAJA TENSIÓN Ver Advertencias en las Páginas 27 y 28...
  • Page 36: Fallas (Aperturas) En Cables

    275HVD de modo que se active y luego mueva el 275HVD a lo largo del cable hasta que haya un cambio en la condición del instrumento. La alarma sonora y el LED deberán estar activos cuando el sensor esté...
  • Page 37: Mantenimiento

    Contacto: Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® Teléfono: +1 (603) 749-6434 (Ext. 351-inglés / Ext. 544-español) Fax: +1 (603) 742-2346 Correo electrónico: techsupport@aemc.com Detector de Alta Tensión Sin Contacto Modelo 275HVD - Manual de Usuario...
  • Page 38: Garantía Limitada

    Correo electrónico: Precaución: Recomendamos que el material sea asegurado contra pérdidas o daños durante su envío: NOTA: Debe obtener un número de CSA antes de devolver cualquier instrumento. Detector de Alta Tensión Sin Contacto Modelo 275HVD - Manual de Usuario...
  • Page 39 NOTAS:...
  • Page 40 99-MAN 100264 v12 AEMC Instruments ® 15 Faraday Drive • Dover, NH 03820 USA Phone/Teléfono: +1 (603) 749-6434 • +1 (800) 343-1391 • Fax: +1 (603) 742-2346 www.aemc.com © 2003 Chauvin Arnoux , Inc. d.b.a. AEMC Instruments. All Rights Reserved. ® ®...