Univox® FSM
Digital Field Strength Meter for AFILS
User manual
To download the test tones and
commissioning reports, please visit
univox.eu or scan the QR code.
Hearing excellence since 1965

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FSM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Univox FSM

  • Page 1 Univox® FSM Digital Field Strength Meter for AFILS User manual To download the test tones and commissioning reports, please visit univox.eu or scan the QR code. Hearing excellence since 1965...
  • Page 2 Instructions ..............................3 Initial setup ............................3 Inserting the batteries ........................4 Field strength calibration ......................... 4 Using the FSM ............................. 4 Audio output ............................5 Auto power OFF ..........................5 The magnetic field sensor ....................... 5 Instruction for use ........................... 6 Specifications ............................
  • Page 3 The Univox® FSM is a digital meter and listener for measuring, testing and commissioning Audio Frequency Induction Loops (AFILS). The FSM is designed to offer a fast, reliable and precise method of verifying, checking and testing and induction loops performance to IEC 60118-4 by both professionals and laymen.
  • Page 4 Note: When replacing batteries, remove the batteries with the FSM switched ON. If the FSM in switched OFF, wait 15 seconds to allow for any residual charge in the internal circuits to dissipate before replacing the batteries. When the FSM is in standby mode the residual charge will keep the unit active for 10-15 seconds.
  • Page 5 EQ settings. Control and adjust the volume by turning the thumb wheel next to the headphone jack left or right. Auto Power OFF The FSM will automatically go to sleep after 40 minutes if no input from buttons or the magnetic field strength is detected above the lowest LED. The magnetic field sensor The pick-up coil used to detect magnetic fields receives a maximum signal when the FSM is in an upright vertical position.
  • Page 6 • Power ON the FSM and touch the RANGE button to select low range. • Hold the meter in an upright vertical position with the depression on the back of the silicone case at the intended listening height.
  • Page 7 • If the FSM does not indicate any signal present, switch to HIGH RANGE and turn FLAT off to verify that there is no high-level background noise emanating from the system.
  • Page 8 At the end of their useful life, the packaging, product and batteries should be disposed of via a suitable recycling centre. Do not dispose of with your normal household waste. Do not incinerate. Bo Edin AB / Univox +46 (0)8 767 18 18 info@edin.se...