Risk of freezing When the BHZ 3.0 is not in use for a longer period (e.g. during holidays) in a room without heating, there is a risk that the water will freeze in pipelines. Freezing water can damage the pipelines and cause consequential damages.
1.6.4 Conformity Hereby we declare as the manufacturer that this product - BRUNNER Heating Center 3.0 (BHZ 3.0) - complies with the basic guidelines for sale in the EU. 1.6.5 Obligations of our Natural Power Partners To ensure the proper functioning of the BHZ 3.0, observe the following guidelines: Instructions for Use BHZ 3.0 (6.14)
Product description The BRUNNER Heating Center (BHZ) 3.0 consists always of a Hydraulic Box and a dedicated System Stor- age. Together they form a functional unit. The Hydraulic Box is capable of handling power ranges from 15 up to 50 kW. The external dimensions of the Hydraulic Box are identical for all variants.
The Hydraulic Box controls the coordination of all connected heat generating devices and all heat con- sumers. The BRUNNER System Storage is optimized for use as buffer tank with renewable energy sources. The pur- pose of the System Storage is the collection, storage and supply (on demand) of all energy streams.
Page 14
The identification plate is found on the System Storage upper part, under the insulating trim. This identification plate is valid for the System Storage, as well as the Standard Storage Tank from BRUNNER. The following information can be found...
Overview of components and connections on the BHZ 3.0 Heating Center The BHZ 3.0 Heating Center con- sists of: A = Hydraulic Box B = System Storage The connections can be arranged on the left or right, depending on conditions on site.
The front panel of the BHZ 3.0 is made of high of powder-coated steel. The lid of the panel can be opened and locked in the open position. The front panel can be easily detached, ensuring a perfect access to all parts of the Hydraulic Box.
2.4.8 Heat pump integration The integration of heat pump in the hydraulic box of the BHZ 3.0 is possible by using the heat pump connection line with a manifold kit and 2 corrugated tubes. The heat pump in- tegration is arranged only for the BRUNNER heat pump BWP 9 green or BWP 13 green.
Page 30
40 litres per minute. - a circulation pump BHZ 3.0 with 3rd and 4th heating circuit. To upgrade the existing heating centre with a 3rd and 4th heating circuit, it is possible to connect a BRUNNER heating circuit pump unit with a manifold.
Page 31
- fresh water module with a 40-litre PHE; - a circulation pump These are only a few installation examples. The modular construction of the BHZ 3.0 allows for flexible, user adaptable heating centre set up - with only a small effort.
Storage tank The BRUNNER storage tank is a buffer tank which is optimized for use of regenerative energy supplies. It’s designed to avoid mixing of water during loading and unloading of the storage tank. Hot water has a low- er specific density as cold water, leading to a physical separation inside the tank. The hot water has a low- er weight and rises up.
Illustration 15: Connection between Standard and System Storage tanks See chapter Dimension drawings : BHZ 3.0 with 750 Liter System Storage and 750 l additional storage tank BHZ 3.0 with 1000 Liter System Storage and 1000 l additional storage tank BHZ 3.0 with 1500 Liter System Storage and 1500 l additional storage tank...
Tel.: 08721/771-0 Touch Display The BHZ 3.0 is equipped with a touch-sensitive display to make operation simple and easy to understand. The touch-sensitive display is a combination of input and output device, which enables direct control of regu- latory functions by touching the screen itself, or certain parts of the displayed screen.
Depending on installed components, there are small differences in actual view of display screen. In example 1: a BHZ 3.0 with logwood boiler as main energy source and additional heating system with so- lar heating and gas boiler. Energy receivers are represented by 4 heating circuits (for heating) (connected with EWP-HK) and a hot water station.
Page 40
In example 2: a BHZ 3.0, which has a BRUNNER heat pump green as an energy supplier. The energy con- sumer is 1 heating circuit and the hot water station. In addition, the cooling function of the heat pump is ac- tive.
Page 42
(e.g. Gas, Oil etc.) Brunner Natural Power Boiler as heat generator: logwood boiler of pellet boiler - in the middle of the field, the current operational status of the biomass boiler is shown, and in the lower part of the field, the type of energy source (e.g.
A distinction is made here between BRUNNER boilers (existing boiler control board) and other boilers provided on site. In the case of BRUNNER boilers, data exchange is performed via CAN bus, which in- cludes also feedback information on combustion status.
The display of a third-party heat generator (in this example, a logwood boiler), provided by other manufactur- ers than BRUNNER, has the following meanings in Home view: The heat generator is set to Off. It is not ready for operation.
3.7.1.4 Brunner wood boiler Home view By clicking the softkey for Biomass heat generator (e.g. Brunner Logwood Boiler or Pellet Boiler = a boiler control board is present), you can retrieve or set the following data: Illustration 23: Menu Page 1 Logwood boiler...
The BWP was switched off by the control system When the heat pump is running, the current output of the BRUNNER Heat Pump is displayed with exact value and current efficiency: Illustration 32: Efficiency is sufficient...
= graphical overview of the system Button for direct access to Tiled stove (i.e. water-bearing stove) Button for Home view of the BRUNNER Heat Pump for direct access to different levels of user set- tings Heating button = for different levels of settings for the existing heating circuits...
Heating = link to Heating System application (BHZ 3.0) EOS = Electronic Stove Control = link to available EOS application BRUNNER Heat Pump button/display field with current COP (coefficient of performance) values Button/display field for the heating source Tiled stove with current temperature value...
Page 71
Current time Button for direct access to heat pump Home view (current view) Button for direct access to BHZ 3.0 Home view Button for direct access to Home view or settings for the integrated EOS control system Info field = display of current heat pump operating status (ready; active; off, error)
3.13 Individual settings 3.13.1 Display customization The touch display of the BRUNNER systems can be customized with various display options. This chapter describes all the setting options for the display presentation. Touch the Settings button and enter your PIN code.
Illustration 55: System/Anlage site 1 Illustration 56: System/Anlage site 2 If you are the operator (end customer) of the BRUNNER system click on the gray button next to“Kunde”. The highlighted field turns orange. When clicked the Subject button or Max@muster- mann.
3. if the system or control panel is now running an update sequence? Please wait until finished and try again. Instructions for enabling Service access The access to service functions can be enabled exclusively for heating contractors or BRUNNER service technicians. Mutual access for both categories of servicemen is not possible.
Page 91
3.3 Enter your password (entered beforehand and repeat - see 1.8) 3.4 The control unit (touch display) of the Brunner system must be reg- istered. To do this, click the New Control Neues Bedienteil. NOTE: If you had previously registered a different control unit, click the Add another control unit button Weit- eres Bedienteil hinzufügen.
Page 96
PC. 7. Registration of your Brunner system 7.1 The control unit (touch display) of the Brunner system must be reg- istered. To do this, click the New Control Unit button Neues Bedien- teil.
Page 99
The current overview of your system will appear on the screen of your PC, notebook, tablet or smartphone. On the Touch Display of your BRUNNER system To see the myBRUNNER status click: Settings + PIN-Code (9999) / Bedienteil(=control panel)/ my-...
3.14.3.3 Enabling for Service access To enable Service access for BRUNNER technicians or a heating contractor, the owner of the system must approve it first. This is done using a fixed Service PIN Code, which is defined in the User account.
The disabled time alignment is displayed with a gray box. The adjustment of the time or date with the BRUNNER network can be activated at any time. 3.14.4 Set up WLAN 3.14.4.1 Set up WLAN - during commissioning Commissioning is user-defined.
→ Working on systems is allowed only for trained service personnel. The parts of the BHZ 3.0 should be periodically cleaned and checked. Apart from occasional visual inspec- tion there are no special maintenance works necessary. After a long operation, some components of heating system can tend to cause malfunctions.
. Cleaning and maintenance Cleaning of external surfaces The external surfaces of Hydraulic Box and System Storage tank of the BHZ 3.0 should be cleaned by the User: Clean or wipe the external panels with a damp cloth. Do not use any aggressive or corrosive cleaning agents.
6. After the update is completed, a window will show up with the text Entfernen Sie den USB-Stick (USB key can be removed); 7. Disconnect the power supply from the complete system (control board of BHZ 3.0); 8. Remove the USB key from display unit;...
Page 124
Return flow increase 30 kW - Wilo Stratos Para 30/1-9 PWM1, 180 mm or 50 kW - Wilo Stratos Para 30/1-8 PWM1, 180mm. via 230 VAC switch contact or potential-free relay in combination with BRUNNER- Switching Natural Power boiler. with differential temperature control and minimum temperature limitation, or when Switching temperatures are lower than set for the system in corresponding standby times.