OS-620 uPure 2 Thank you for purchasing the OSIM uPure 2. Before you start using the uPure 2, please read the operation manual thoroughly for the correct methods of usage, especially taking note of the section on Safety. This manual should be kept on hand for easy reference. It is your guide to a safe and efficient operation.
To keep the outlet clean, run the purified water for about 10 seconds before use everyday. • If the uPure 2 has not been used for more than two days, run the purified water for 60 seconds to keep the outlet clean. •...
Page 5
• Do not use the uPure 2 near high temperature utensils or fire. • Do not freeze the uPure 2. This will result in breakage of the filter cartridge. • If attached on faucet used for hot and cold water, users may experience difficulties in water heater’s gas ignition.
Page 6
Safety When the uPure 2 should not be used • If the lower portion of the spout extends down less than 15 mm. 15 mm • If the tap has a diameter of more than 25 mm. 25 mm •...
Page 7
• Do not modify the uPure 2 in any way. • If the back of the uPure 2 interferes with the faucet, attach the uPure 2 with the switching lever at front as shown in Fig. 1. Top view of tap Side view of tap Fig.
Names of parts and functions Main body 1. Attachment nut 8. Tap water outlet 2. Type A adaptor (16mm) 9. Mode switching lever 3. Attachment rubber washer 10. Cartridge replacement indicator 4. Attachment mesh filter 11. Filter cartridge 5. Main unit 12.
Page 9
Names of parts and functions Adaptor set Type A : For taps Type C : For taps • • with a round spout with a foaming cap (inner threaded) White : 16mm (on main unit). Blue : 17.5mm. Blue : For Grohe taps. Grey : 19mm.
Features and effectiveness Features • Cartridge Replacement Indicator displays the replacement date of the filter cartridge (in months). • Multi-step purification process to effectively remove bacteria, odour and very fine particles. • High capacity 1500-litre* double filtration cartridge using hollow filament membrane and granular activated carbon.
Page 11
Features and effectiveness Effectiveness • The bacteria reduction performance test complies with the Japan Water Purifier Association (JWPA) Voluntary Standards for water purifiers. The water purifier is proven to remove 99.99% of the known bacteria as set in the standards by JWPA. •...
Preparation before use Installation of filter cartridge • Turn the cartridge cover in Cartridge Cover an anti-clockwise direction to remove it. • Insert the cartridge by aligning the line on the cartridge with the groove on the main unit. • Turn the cartridge cover in a clockwise direction to tighten it.
Page 13
Preparation before use Cartridge replacment indicator • Turn the cartridge replacement indicator in a clockwise direction to 5 months from the date of installation to set the time for replacing the cartridge.
Page 14
Preparation before use Selection of adaptors Type A: For taps with a round spout Use Type A 16 mm 17.5 mm 19 mm White colour for 16 mm (Small). Blue colour for 17.5 mm (Medium). Grey colour for 19 mm (Large). Type B: For taps with a foaming cap (outer threaded, 22 mm) Use Type B Diameter of...
Page 15
Preparation before use Type C: For taps with a foaming cap (inner threaded) Use Type C KVK tap Grohe tap White colour for KVK taps. Blue colour for Grohe taps. Type D: For other types of taps (with straight spout) Use Type D 15 mm or longer Diameter of less...
Page 16
• Pass the attachment nut over • Slip the Type A adaptor the tap. over the spout. • Tighten the attachment nut • The uPure 2 is now ready to prevent water leakage. for use.
Page 17
Type B adaptor and fit it onto the tap. adaptor onto the tap. Ensure that the screw threads match. • Tighten the attachment nut • The uPure 2 is now ready to prevent water leakage. for use.
Page 18
Type C adaptor and fit it onto the tap. adaptor onto the tap. Ensure that the screw threads match. • Tighten the attachment nut • The uPure 2 is now ready to prevent water leakage. for use.
Page 19
Attachment Type A adaptor • Fit the Type D adaptor onto • Remove the attachment nut the uPure 2. Ensure that the and Type A adaptor from the screw threads match. uPure 2. • Attach the Type D adaptor •...
Operation 1. Purified water • For cooking and drinking. • Turn the Mode Switching Lever to [ • Water will flow from the Purified Water Outlet. 2. Tap water (Shower) • For gentle rinsing. • Turn the Mode Switching Lever to [ •...
Replacement of cartridge Cartridge replacement is dependent on various factors, such as the amount of water used, water pressure, geographic regions and water quality. If any of the following conditions applies, please replace the cartridge. (Refer to installation of filter cartridge on page 10 for to replace cartridge).
Page 22
Replacement of cartridge 4. The recommended time for replacing the cartridge is about 5 months. For standard tap water with chlorine density regulated to 2ppm or less, the chlorine removal function is effective for 1500 litres. On average a family of three to four people uses about 10 litres of purified water a day.
Product care and storage Cleaning and storing the uPure 2 • You may wipe the uPure 2 with a damp cloth. Be sure to wipe the uPure 2 and parts dry before storage. • Do not use cleaning agents such as benzene or thinner to clean the uPure 2.
Troubleshooting If you encounter problems with the operation of the uPure 2, please check the following points to see if they can be rectified. If the uPure 2 still malfunctions or does not work, please contact OSIM Service Centre*. Do not dismantle or attempt to repair the uPure 2 yourself. Doing so will void the warranty and OSIM will not bear any responsibility for any subsequent consequences.
Specifications Product OSIM uPure 2 Model number OS-620 Filter Activated carbon, Polysulfone hollow fibre membrane Filtration flow rate 2 litres/minute (Water pressure: 100kPa, water temperature at 20˚C) Filtration capacity Residual Chlorine - 1500 litres (Test water concentration at 2ppm)* Turbidity - 2000 litres (Test water at 20˚C)*...
Need help?
Do you have a question about the uPure 2 and is the answer not in the manual?
Questions and answers