Advertisement

Quick Links

Operations and Maintenance Manual
PTL-TYPE-1 mode of operation (remote controlled only)
This Portable Traffic Lights is a lightweight traffic light. As such correct operation for
Set-up and Take-down procedure is essential. Please ensure this manual is read and
understood before attempting to operate the Data Signs' Portable Traffic Lights (PTL).
Set-up and Maintenance requirements of the PTL are covered by this Manual.
10:14am
4G
PTL PTLSG
EXIT
STOP
GO
Shut Down
MENU
Remote
Battery
Showing optional Ballasts.
Ballasts are mandatory for QLD.
© 2024 Data Signs Pty Ltd. All rights reserved
Showing optional
target board.
Target boards are
mandatory for NSW.
P T L - S 1 O P E R A T I O N S M A N U A L
|
UNCONTROLLED WHEN PRINTED
CAUTION:
The Data Sign Portable Traffic Lights should
only be operated by qualified traffic managers.
If you have hired out this PTL, contact the Hire
Company for assistance.
The PTL-S1™ is used to control localized vehicular
traffic flow as a safer substitute for STOP/SLOW
(lollipop) signs.
It is powered by a LiPo maintenance free battery
that needs to be recharged at the end of the day.
It is not intended to be left unattended on site and
can only be operated via the Remote Control which
places a safe distance between the actual Traffic
Light and the operator.
An overview of the layout of the PTL-S1™
equipment is provided here.
|
MAN 0011F Issue 1
|
Rev: 12/02/2024
1

Advertisement

Table of Contents
loading

Summary of Contents for Data Signs PTL S1

  • Page 1 This Portable Traffic Lights is a lightweight traffic light. As such correct operation for Set-up and Take-down procedure is essential. Please ensure this manual is read and understood before attempting to operate the Data Signs’ Portable Traffic Lights (PTL). Set-up and Maintenance requirements of the PTL are covered by this Manual.
  • Page 2 Installation - Setting Up for Operation Step 1: Step 5: Take out the stand. Fit Battery Box. Step 2: Step 6: Loosen locking tab, Twist and fit around lift the post to the the post. pin-hole & place Close and lock pin.
  • Page 3 Installation - Target Board Setup (if supplied) Step 1: Step 5: Remove the four Now, assemble the parts from the side bottom panel as pocket. shown. Step 2: Step 6: Assemble this way. SCAN FOR VIDEO PRESENTATION OF THIS PROCESS Step 3: Align and assemble top section to the 2...
  • Page 4: Table Of Contents

    PTL-S1 ™ PTL Remote This QuickStart Guide covers the PTL TYPE-1 Operation as per QLD MRTS264, TSI-SP-049-050-062, Australian Standards AS-4191:2015 and Various State Authority requirements. Ensure the units are setup as described in the first section of this booklet. This User Manual applies to Controllers operating on firmware 06.00.XX or later.
  • Page 5: Ptl Remote

    The PTL Remote Once the power switch has been set to ON, the PTL Light will go through a start up sequence. When completed, the lights will show the self test and the buzzer will sound, it is then ready to pair to the remote.
  • Page 6: Self Test

    STARTUP / SHUT DOWN To Shut the light down or Start them up again, tap the START UP / SHUT DOWN button and confirm by allowing count to continue for 5 seconds. The Light will go blank, or start up whichever the case might Once the lights are BLANK, switch them off and recharge the battery for the next time.
  • Page 7: Gating Control Mode

    Gating Control Mode Scan the QR code Single PTL unit use only. Gating Control is used to control the flow of traffic as per below illustration. Roadworks Site Gating control can also be used with 2 or more PTL units operating independently by traffic operators, using a Walky-Talky to communicate with each other as per below.
  • Page 8: Battery Charging

    The PTL Controller is fitted with a SD card. This is used for Software upgrades. If required, Data Signs will advise process to be used. D A T A S I G N S A U S T R A L I A P T Y L T D...
  • Page 9: Maintenance

    Signs. This charger must not be modified or used for any other purpose. Handling In the event a battery needs to be replaced please contact Data Signs. The lithium ion batteries are generally very reliable and replacement is unusual. It is possible there are other operational issues.
  • Page 10: Wind Loading, Ballast Requirements

    TSI-SP-062,049 and 50 where relevant AS4191-2015 Portable Traffic Signals. Suggestions & Improvements Data Signs develops its products with the end users in mind. As such, we are always open to suggestions for product improvement. Contact Data Signs, Head Office in Australia at: datasigns.com.au/help...