Ksenia in Italy, is a BUS peripheral connected to the lares 4.0 control panel via KS-BUS and it represents the physical core of the Access Control system designed by Ksenia.
Installation and Configuration Manual Architecture solution Technical data • 1 door managed • 2 BUS interfaces: • System BUS: 3 wires (A, B, -) link to lares 4.0 (NO power from KS-BUS) • Peripherals BUS: 4 wires (+, A, B, -) link to two local peripherals (volo, volo-in or ergo-X) supporting the access control function •...
Installation and Configuration Manual Quantity data lares 4.0 models wls 96 40 wls 140 wls 644 wls Maximum number of intro modules 12 (20*) 16 (30*) * Extended number is available under license, contact our sales team for information.
Page 8
Output#1: NC or NO (factory setting) dry contact of output #1 depending on jumper settings) Output#1: common contact of output #1 (30Vdc - 1A max) Ground terminal (*) LOW BATTERY and AC MONITOR inputs work correctly with power supply provided by Ksenia. R30057.111...
Installation and Configuration Manual Jumper settings Jumper Setting Description Setting Description 1-2* LOCK#1 - Lock power supply input from LOCK#1 - Lock power input from external source through pin cL1 +V power supply input 1-2* LOCK#1 - NO contact...
1. on a DIN bar inside a suitable box for installation; 2. Ksenia Kit code KSI2800001.300: intro with white plastic cabinet with front opening and screw closure and, depending on the type of lock, select between the 13.8V UPS kit (KSI7101260.000) or the 27.6V UPS kit (KSI7102460.000).
Installation and Configuration Manual Wiring the system Wiring intro SYSTEM BUS to lares 4.0 KS-BUS Note: DO NOT connect [+] terminal of lares 4.0 KS-BUS Wiring intro PERIPHERALS BUS with ergo-X/volo/volo-in devices R30057.111...
Installation and Configuration Manual Wiring LOCK1 output 1st option: Lock power supply directly from intro 2nd option: Lock power supply from other source than intro Wiring input terminals R30057.111...
Installation and Configuration Manual The intro module provides 7 inputs, 5 of which are programmed with functions already defined as summarized in the following table: Input label Function Description DOOR STATUS To be connected to an external magnetic contact (or, if present, internal to the electronic lock) it is necessary to detect the status of the door (Open/Closed).
Installation and Configuration Manual The intro module provides 6 outputs, 2 of which are programmed with functions already defined as summarized in the following table: Output label Function Description GATE STATUS Connected to a lamp (for example) it is automatically activated when the gate is disabled;...
Installation and Configuration Manual intro module configuration intro BUS Peripheral menu Real time data Label Possible values Gate Enabled = allows access only to authorized users. (intro module) Disabled = access not allowed to users even if authorized. The gate is automatically disabled when at least one of the configured partitions is armed.
Page 16
Installation and Configuration Manual Logical Gate Status Logical status comparing values of Gate, Door Status (i3 input – DOOR STATUS) and Bolt Status (i5 input – BOLT STATUS). Depending on combinations of possible values, it can assume: Open, Forced Open, Open Too Long, Failure, Enabled, Disabled.
Rooms You can set one or more rooms to display intro on graphic Maps and lares 4.0 User App (the door category icon is used). i1= (input terminal 1 - freely configurable)
Page 18
Note: this zone is like all the others, if you want it to be armed when the gate is disabled, the configured partition must be equal to, at least, one of those configured in the intro device, which disables the gate if armed. i4 (Input Terminal 4 - preconfigured as RTE-Request to exit) It does not require configuration, default NO, it is sufficient to physically connect it to an RTE output button.
Installation and Configuration Manual Enabling DOTL and FD alarms ATTENTION! It is necessary to associate a zone with the i3 terminal to read the door status and for the DOTL (Door Open Too Long) and FD (Forced Door) events to be generated.
Gates: The list contains the names of the gates configured in the system by the installer (in our example the list contains only one intro). The Administrator user has the possibility to associate all gates to each programmed access permission.
Installation and Configuration Manual Configuring users and authorize them to pass through the gate Step Menu Description User Management -> Users From Installer – Installer From Installer – Administrator User level From lares 4.0 App with Administrator level Add two users: Employee-user-name and assign the Employee profile.
Commands - Open door Opening the door with PIN, with • From Installer - Installer: BUS Peripheral ->intro -> Command RFID key, from lares 4.0 APP and section -> Door Opening, click Open; enter PIN if required; from web interface •...
Installation and Configuration Manual Diagnostic intro module is visible on the Diagnostics page of the system, like all other devices; intro Peripherals BUS is handled like opis and divide branches. The current consumption of intro is 0 (zero) because it is powered by external power supply; the devices on intro Peripherals BUS are powered by intro itself so the consumption is not visible.