Page 1
OPERATION MANUAL COLOR RADAR KODEN ELECTRONICS CO.,LTD. 5278 UENOHARA, UENOHARA-MACHI,KITATSURU-GUN MDC-1041/1040/1060/1010 YAMANASHI, 409-0112, JAPAN TEL: +81 554 20 5865 FAX: +81 554 20 5880 http://www.koden-electronics.co.jp/ 2001 VI TC 0.05Z1 2002 III TC 0.03Z5 PRINTED IN JAPAN 93142022-...
Page 2
This indicates the ground (earth) terminal. If the equipment cannot be grounded via the power cord, connect this terminal to ground. There is a risk of serious electric shock if the equipment is not grounded. MDC-1041/1040/1060/1010 Color LCD Radar Operation Manual MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Only qualified personnel should remove covers on these parts. WARNING for Display Unit; There is a risk of receiving electric shock if these parts are touched by accident. Only qualified personnel should remove covers on these parts. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Page 4
Mount the unit so that it will not be subject to these forces. * Mercury (Hg) is used in the LCD backlight. When the unit is taken out of service, it should be disposed of according to local regulations regarding hazardous materials. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Page 8
8.6 Options ----------------------------------------------------------------------------------------- 75 8.7 External dimensions and weight --------------------------------------------------------- 75 8.8 External connection and function -------------------------------------------------------- 75 APPENDIX ...................77 MDC-1041 GENERAL SYSTEM DIAGRAM--------------------------------------------------------------- 77 MDC-1040 GENERAL SYSTEM DIAGRAM--------------------------------------------------------------- 77 MDC-1060 GENERAL SYSTEM DIAGRAM--------------------------------------------------------------- 78 MDC-1010 GENERAL SYSTEM DIAGRAM--------------------------------------------------------------- 78...
The RADAR is a compact marine radar that delivers a peak antenna power output of either 4 kW (MDC-1041/1040), 6 kW (MDC-1060) or 12 kW (MDC-1010) and has a 10.4-inch color 640 x 480 liquid crystal display. It uses a microcomputer and a video signal processing LSI chip specifically designed for radars to deliver high performance and a wide range of features.
The lower the side lobe level, the less the effect of a false echo. The MDC-1041 radars are equipped with a closed dome scanner; the MDC-1040/1060/1010 has a larger, open array. Side lobe...
The other is a ghost echo generated by a re-reflection of the original signal. It comes back to your own boat, bounces back to the target, then is picked up by the an- MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Page 12
CAUTION When near large targets or land, your boat's mast may sometimes appear as a circular-arc shaped false echo. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Page 13
The interference usually appears as spiral or radial patterns. The RADAR has two levels of interference rejection control to eliminate interference. Turn it on to reduce or eliminate the interference. Radar inrterference Fig.2-8 Radar interference MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Course Up (CU) This is similar to North up except that your boat's destination is at the top of the screen. A straight line from the bottom to top of the screen is your course bearing. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Page 15
This straight-line marker can be rotated in any direction centered on your boat's position. Use the EBL to indicate the advancing direction of your boat and its relative angle with a target. Equal intervals 0.75 0.25 Echo Fig.2-12 EBL MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Page 16
In such a case, echo images on the screen can be made easily distinguishable by adjusting FTC. FTC OFF FTC ON 0.75 0.75 0.25 0.25 Small noises are reduced. Fig.2-14 FTC PPI (Plan Position Indicator) A display system of radar. Reflected radar signal is displayed in plan. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
M10 hexagonal bolt 4 sets M12 hexagonal bolt 4 sets 4 sets 4 sets Carbon brush Your unit was shipped with a 10m interconnecting cable. Longer cable is also available as an option, as listed in Tab.3-1. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
T3.15A/250V or 125V* 5A/250V or 125V (5Φ x 20mm) T3.15A/250V or 125V* DC24V (5Φ x 20mm) T3.15A/250V or 125V* (5Φ x 20mm) (5Φ x 20mm) Note: A fuse with an asterisk (*) is fitted as standard. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
A place where the display unit is more than the minimum safe distance from a magnetic compass as listed in Tab.3-5 below. Tab.3-5 Minimum Safe Distance from Magnetic Compass Standard compass Steering compass Scanner unit 2.0m 1.4m Display unit 2.0m 1.4m MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
By raising the dip angle above 5°, it is possible to prevent mid- and long-distance shadow zones. The radar cannot detect objects below the line of sight. Horizontal line θ Line of sight Fig.3-2 Obtaining sufficient dip angle MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
(2.36 in.) Unit : mm Forward Fig.3-6 Hole positions for display unit WARNING Do not mount the display where it will be operating in direct sunlight. The excessive internal heat buildup may damage the unit. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Make sure that the cover is positioned in the correct direction as shown in Fig.3-7. The upper and lower parts of the radome each have four alignment markings indicating screw positions. Logo seal on side wall Ship's heading Cable inlet Fix four screws Fig.3-7 Fitting cover MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
(The crimp terminal and grounding wire is user supplied.) Chassis Scanner cover Radome(bottom) Mount base → To ship's hull Crimp terminal Grounding wire Grounding wire →To ship’s hull Open scanner Radome scanner Fig.3-11 Grounding scanner unit to earth MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
When you have finished installing the scanner and display units, turn on the power to see if they operate. Then make adjustments as detailed below: TUNING Refer to Adjusting tuning circuit in 5.5.4.6.5 HEADING DIRECTION Refer to Adjusting angle in 5.5.4.6.5 DISTANCE Refer to adjusting distance in 5.5.4.6.5 MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
A connection should be made at the main breaker panel or as close to the generator or battery as possible. Connection A and B are recommended. Connection C should not be used. Connection A MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Tab.3-7 lists the primary component materials of the RADAR. Dispose of them according to local environmental and recycling regulations. Tab.3-7 Component Materials Scanner unit Material Display unit Material Radome Front panel Chassis A5052P Rear panel ADC12 Base ADC12 Pedestal ABS+PC Antenna A5052P MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
ALL PPI2 NEXT NEXT NEXT NEXT (Factory setting, V5.01 and higher, with ATA installed) *Every time the "NEXT" soft key is pressed, the soft key group changes as follows: SET1 → SET2 → SET3 → SET4 MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Track (LAT/LON or Distance/Bearing) EBL2 4.5 Radar screen (All PPI screen) Pulse width Off-center Range OFF-C Picture hold Range ring interval HOLD Zoom ZOOM Display mode GZ IN Guard Zone 1:58 RADAR OFF Cross cursor MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
(Pressing any other key afterwards will access the function of that key.) BRILL Control knob (Adjustment of brilliance) BRILL or ENT Up/Down Selection of key-backlight Other function key Move to other functions ST’BY BRILLIANCE KEY BACKLIGHT MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
(2) Turn the control knob to select an acceptable level. The numbers will move in a range of 0 to 99. (3) Press the "GAIN" key to exit from the adjustment state. You can also press any other key and continue with that function. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Other function key - Shift to other functions AUTO AUTO ------------------- GAIN, STC, and FTC are set at AUTO and these functions will become ineffective. To switch from the MANUAL state AUTO ------------------------------------------------------------- Set GAIN, STC and FTC at AUTO MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
POB screen, POB data will be cleared and you will return to previous screen. If you press any other key, the POB data will remain and you will return to the previous screen you had been viewing. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Use the cursor pad to position the cross mark on one of the echoes, then press "ENT". Press "EBL2", then rotate the control knob until the electronic bearing line is centered on the second echo. The angle of a line between the two objects relative to your boat's heading will be displayed MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
FL VRM2 TRACK PPI/NAV ALL DEL ALL PPI TARGET SEL WIN OFF-C PICTURE ALL PPI2 NEXT NEXT NEXT NEXT The function can be changed at the "KEY ASSIGNMENT" function in the "CUSTOM" menu of the "SETUP". MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
"OFF-C" will be displayed at the upper right of the screen. To cancel the off-center function, press "OFF-C" again. Note: *VRM2 and EBL2 start point do not follow the OFF-C function during a floating state. VRM2 and EBL2 functions will work in the OFF-C mode. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Press the "ST" key repeatedly to alternate between them and to turn off the function. Note: Refer to "5.5.3.5 Echo expansion (ST)". ST1 → ST2 → OFF Expansion rate ST1 < ST2 ) MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
"SEL WIN". Note: Refer to "5.5.4.2 Switching screens on PPI/PPI screen ( SEL WIN )". SEL WIN (Select right screen) Right screen activated or (Select left screen) Left screen activated MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
PPI window and a navigation data window. The ZOOM, <<<< 267.3°T OFF-C, FL EBL2, and FL VRM2 functions cannot be used in 12.8 TEMP 20.8° this mode. DEPTH 58.3 LAT/LON 34° 08. 22N 138° 02. 53E PPI/NAV screen MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
The right screen picture is frozen during the refresh period for the left screen, and vice versa. We recommend when cruising at higher speeds to use a single PPI screen for continuous image refreshing. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
To remove it, either use the menu or press the VRM1 soft key. Up/Down Up/Down Control knob MENU (Select VRM1) (Select ON) (VRM1 operation) Other function key Note: xx.xx NM indicates VRM1 . MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
The angle is relative to either the boat's heading, true or magnetic north, depending on the setting of "EBL BRG" in the "SETUP>CUSTOM>PRESET1" menu. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
0.25 0.25 0.25 Open antenna (MDC-1040) Range 0.125 0.25 0.75 Number of Rings Interval 0.0625 0.125 0.25 0.25 0.25 Open antenna (MDC-1060) Range 0.125 0.25 0.75 Number of Rings Interval 0.0625 0.125 0.25 0.25 0.25 MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
(4) The data will be displayed in the lower left corner of the screen. (5) Turn off the function using the menu or press the "+MK LINE" soft key. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Page 52
+MK LINE function is turned OFF +MK POS +MK POS ° ° 230.0 230.0 0.47 0.47 +MK LINE OFF +MK LINE ON The distance/bearing marker follows to cross cursor. EBLs and VRMs can be used separately. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
(3) Use the up-down and left-right cursor keys to move the cross cursor to the center of the warning zone to be set, and press the "ENT" key. (4) From the cross cursor position you set as the center, expand the guard zone as follows: MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
You can set the "SLEEP" function for a 5-, 10- or 15-minute interval. Two minutes before a specified transmission time, the screen backlighting turns on and the warm-up timer starts. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Then, repeat from (1) to (4). (5) To discontinue tracking a target, select the target number with “TGT NUM” function, then select "DEL" from the menu. To discontinue tracking all targets, select "ALL DEL". MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Set to AUTO mode Note 1: When you select the MANU mode, GAIN and FTC will be switched to MANU mode, also. 2: When you select the HARBOR mode, only FTC will be switched to MANU mode MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
ST2 ENT ----------- (Select OFF) ST OFF (Expansion rate ST1<ST2) ST1, or ST2 display, no display on OFF state The picture to display echoes expanded ST function is OFF in the direction of the distance MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
3: You can only use the ZOOM function on a PPI screen. 4: ZOOM function cannot be used in conjunction with OFF-C. 5: Center of ZOOM can be set anywhere on the screen and in any range. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
(1) Select S/L from the ECHO menu and press "ENT". (2) Select either SHORT or LONG from the box and press "ENT". Up/Down ENT --------------------------- (Select SHORT) Set to short pulse ENT ------------------------------ (Select LONG) Set to long pulse MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
GAIN, STC, FTC TUNE SEL WIN TXON/OFF : Independent control on both screens using SEL WIN : Simultaneous control on both screen : Can only be used on a PPI screens X : Cannot be used MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Rotate the control knob to determine the distance to a Determining the distance with VRM1 on LEFT screen target. In the dual screen mode, VRM2, EBL1, or EBL2 also work the same way. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
POB position and return to the previous SHIP’S POS screen. Press "ENT" to return previous screen but keep 37°12.42N the POB position data. 142°04.33E PRESS POB KEY TO DATA CLEAR PRESS ENTER KEY TO RETURN MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
(3) You can test the functioning of the front panel buttons by pushing them. If they are working properly, their corresponding icons will be highlighted. Rotating the control knob will make a line move inside the box on screen. (4) Press the "POWER" key to return to the previous screen. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Page 64
Indicates the Scanner type ex. 4 KW OPEN p) Front-panel keys As you press any front-panel key when the SYSTEM CHECK screen is on, the corresponding key is highlighted on the screen by displaying it in reverse video. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
(3) Select functions by moving the up-down cursor pad arrows to highlight the item. If an item has a check mark in the box in front of it, that item is currently assigned to a soft key set. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Page 66
TGT NUM Key Groups Move with up-down cursor Move with right-left cursor Mark is displayed when the Operation panel Keys 1 - 7 function is set to a key. Soft Key Setting Screen (with ATA option) MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
°C: ------------Celsius °F: ------------Fahrenheit Depth Unit Set the Depth unit M: -------------Meter FT:------------Feet FM: -----------Fathom Stern Marker EBL Mode Set the Mode of EBL REL: ---------Relative bearing from HM TRUE: -------True bearing MAG: --------Magnetic bearing MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Page 68
6 NM SHORT P TABLE LONG Note: MDC-1041/1040 Pulse width 0 : 0.08 uS, 1 : 0.25 uS, 2 : 0.8 uS MDC-1060/1010 Pulse width 0 : 0.08 uS, 1 : 0.3 uS, 2 : 0.6 uS 3 : 1.0 uS...
Demonstration mode i) Interference Rejection Reject interference from other radars nearby OFF: -- IR OFF IR1:---- ON level 1 IR2:---- ON level 2 j) Boat Speed How the radar will determine and display your boat's speed MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
EBL,VRM operation:X seconds X+30seconds (Time used) NOTE: EBL and VRM function is usable in HOLD state. “HOLD” is displayed and blinks. HOLD ST’BY X+30sec Setting HOLD EBLs and VRMs can be used to locate a target. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
(b). If there is a linear target such as a bridge or breakwater, adjust timing until the target appears straight on the screen. (2-3) When the adjustment is finished, press the "ENT" key to exit from the distance adjustment screen. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Set a value to . HEAD DIRECTION ADJUSTMENT ADJUST WITH CONTROL KNOB PRESS ENTER KEY TO RETURN °_ _358.8 HEADING Adjustment (3) Adjusting tuning circuit (TUNING CAL) This will adjust the automatic tuning circuit to its best operating point MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
(2) “STC CURVE ADJUSTMENT” will be displayed at the bottom of the screen. Using the control knob, choose a desired value from 1 to 9. (3) Press the "ENT" key to exit from the adjusting antenna height screen MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
The G, S, and F readings below it should all have AT next to them, meaning they are all set to the auto mode. AUTO STC will automatically delete echoes within 0.1 NM of your boat. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
(2) “HARBOR STC ADJUSTMENT” will be displayed at the bottom of the screen. Using the control knob, choose a desired value from 1 to 16. (3) Press the "ENT" key to exit from the adjusting screen. Up/Down Control knob Select STC ADJ Choose value Complete MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
If the display screen becomes extremely dark and its illumination cannot be increased by adjusting the Brilliance control, the LCD backlight may be faulty. Contact your dealer or authorized repair center for this service Period of the replacement: 15000hour(typical) (1000hour at 0 °C) MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Page 77
When working on the scanner, you can hang the upper half of the radome using a piece of wire or cord through holes to either side of the mounting screws. Cord A: Top view Hole Radome(bottom) Fixing screw Cord Radome(Upper) MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
(See Section 5.5.4.6.5) actual image. Timing adjustment is incorrectly set. Set timing adjustment cor- rectly. (See Section 5.5.4.6.5) (6) Echo images GAIN, STC, or FTC is improperly set. Adjust. (See Section 5.3.6 to MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Page 79
With radar powered off, press present talker device. and hold POB and RANGE UP keys, then press POWER. When screen lights up, release two buttons. Unit will display actual NMEA data being transmitted. Correct talker as necessary. MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
70 W or less (MDC-1040) 80 W or less (MDC-1060) 90 W or less (MDC-1010) Distance range: 0.125 to 36 NM, 10 ranges(MDC-1041) 0.125 to 48 NM, 10 ranges(MDC-1040) 0.125 to 64 NM, 11 ranges (MDC-1060) 0.125 to 72 NM, 11 ranges (MDC-1010)
Gyro Interface clock (+) input GYRCK- Gyro Interface clock (-) input Apply 5V pulse between (+) and (-), isolated GYRDT+ Gyro Interface data (+) input GYRDT- Gyro Interface data (-) input Apply 5V pulse between (+) and (-), isolated MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Page 84
Compass Interface for SIN/COS type Compass Interface for SIN/COS type Compass Interface for SIN/COS type SIN/COS signal: SIN = REF±1V, COS = REF±1V Dry contact log pulse input NMEA_OUT NMEA data output, ex) POB data, TARGET data MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Appendix 1. MDC-1041 General System Diagram Scanner unit RB715A Inter Connection Cable (10 m standard) Radar signal output Radar signal input Display unit Display unit NMEA0183 input MRD-97 MRD-97 NMEA0183 output Compass signal input External buzzer Power supply cable NMEA I/F for...
Radar signal output Radar signal input Display unit NMEA0183 input MRD-97B NMEA0183 output Compass signal input External buzzer Power supply cable NMEA I/F for DC power supply Navigation 24 VDC (Nominal) Equipment (10.2 to 41.6 VDC) MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
13 34 YELLOW SHIP’S+ 34 ORANGE +12V 14 Braid of GRAY V/TRG-R Braid of RED DAT-R 15 34 GREEN SHIP’S- 16 34 BLUE SHIP’S- Braid of BROWN BP/SHF-R BROWN BP/HG Braid of GRAY V/TRG-R GRAY V/TRG MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...
Hold (HOLD) .........61 VRM unit (VRM UNIT) ......59 Language ..........61 Way point (WP)........26 WP BRG (Bearing of Way point)..59 +MK LINE ..........43 Menu .............39 XTE (Course error) ....... 25,26 Monitor mode (MONI)......61 ZOOM............ 36,50 MDC-1041/1040/1060/1010 OPERATION MANUAL – 03...