LMI Technologies Gocator 1300 Quick Start Manual

Advertisement

Quick Links

3. S
TARTING GOCATOR
NOTE: Gocator must be connected to a host computer in order to launch the user interface and set up the sensor.
Gocator sensors are configured by connecting with a web browser. For details on browser compatibility, see the user manual.
A. L
AUNCHING THE INTERFACE
Step 1
Change network setting on host computer.
In Windows 7
a. Open the Control Panel > Network and Sharing Center > Change
Adapter Settings.
b. Right-click desired network connection, and then click Properties.
c. On the Networking tab, click Internet Protocol Version 4 (TCP/IPv4),
and then click Properties.
d. Select "Use the following IP address" option.
e. Enter IP Address "192.168.1.5" and Subnet Mask "255.255.255.0", then
click OK.
In Mac OS X 10.6
a. Open the Network Pane in System Preferences and select Ethernet.
b. Set Configure to "Manually".
c. Enter IP Address "192.168.1.5" and Subnet Mask "255.255.255.0", and
then click Apply.
Gocator is shipped with the following default network
configuration:
Setting
Default
DCHP
Disabled
IP Address
192.168.1.10
Subnet Mask
255.255.255.0
Gateway
0.0.0.0
Step 2
Open a web browser and enter the sensor address.
The Gocator interface loads.
An example of the user interface in use
T
ROUBLESHOOTING
PROBLEM
SUGGESTED RESOLUTION
Mechanical / Environmental
The sensor is warm.
• It is normal for a sensor to be warm when powered on.
Connection
• Verify the sensor power is on. This will be indicated by an illuminated POWER LED.
• Verify the Power & Ethernet cordset is connected to the Power/LAN connector and the Ethernet RJ45 plug is connected to the Ethernet switch.
When connecting with a web
• Verify that the client computer's network settings are properly configured.
browser, the sensor is not found
(page does not load).
• Download 14405-x.x.x.x_SOFTWARE_GO_Tools.zip from the downloads area of LMI's website at www.lmi3D.com.
• Download 14405-x.x.x.x_SOFTWARE_GO_Tools.zip from from the downloads area of LMI's website at www.lmi3D.com.
When attempting to log in, the
password is not accepted.
Laser Profiling
• Ensure that the decal covering the laser emitter window, normally affixed to new sensors, has been removed.
When the Play button is pressed,
• Verify that the LASER LED on the Gocator is illuminated. If not, the laser safety input signal is off.
the sensor does not emit laser light.
• The exposure setting may be too low. For more information, see Gocator Web Interface > Scan Setup and Alignment > Sensor > Exposure in the user manual.
The sensor emits laser light, but the
• Verify that the measurement target is within the sensor's field of view and measurement range.
Range Indicator does not illuminate
and/or points are not displayed in
• Check that the exposure time is set to a reasonable level.
the data viewer.
• Review the active measurements and remove any that are unnecessary.
The sensor CPU level is near 100%.
• Consider reducing the trigger speed.
• Consider reducing the laser profiling resolution.
B. R
UNNING GOCATOR
Step 1
Select the Manage page.
Step 2
Ensure that Replay mode is off (slider set to left) and that the
Laser Safety switch is enabled or the Laser Safety input is
high. Press the Start button in the toolbar to start the sensor
(a laser line should now be visible).
REPLAY (off)
Step 3
Move target into the laser plane and measure!
NOTE
Gocator sensors can also interface directly with HexSight.
Refer to the HexSight Quick Start Guide for more information.
See Getting Started > Network Setup in the Gocator user manual or your computer's documentation on configuring a network adapter.
Unzip and run the Sensor Discovery Tool [Discovery>kDiscovery.exe] to verify that the sensor has the correct network settings.
Unzip and run the Sensor Discovery Tool [Discovery>kDiscovery.exe] to find the sensor on the network and click Factory Restore.
WARNING: Performing a factory restore resets your configuration settings to their original values. These settings can be recovered from backup files if you
have previously saved them.
To determine the correct solution for your application, see Specifications > Gocator Power/LAN Connector > Laser Safety Input in the user manual.
The RANGE LED on the Gocator will illuminate when the target is in range.
For more information, see Gocator Web Interface > Scan Setup and Alignment > Sensor > Exposure in the user manual.
RECORD
SNAPSHOT
START
1300
TOP MOUNT PACKAGE
Quick Start Guide
For the user manual, CAD drawings, firmware release notes, SDK,
and more, go to www.lmi3D.com/support/downloads.
15193-01.12_MANUAL_Quickstart_Gocator-1x00-Series-Top-Mount-Package

Advertisement

loading

Summary of Contents for LMI Technologies Gocator 1300

  • Page 1 3. S TARTING GOCATOR NOTE: Gocator must be connected to a host computer in order to launch the user interface and set up the sensor. Gocator sensors are configured by connecting with a web browser. For details on browser compatibility, see the user manual. A.
  • Page 2 1. M OUNTING OCATOR OVERVIEW There are several sensor models in the Gocator 1300 series, each NOTE: Mounting the Gocator is recommended before applying power. Ensure that a proper earth ground is es- designed with a unique Clearance Distance (CD), Measurement Range (MR) and Field of View (FOV).