Beko ATP 6100I - Air Purifier with HEPA Filter and HygieneShield Manual

Beko ATP 6100I - Air Purifier with HEPA Filter and HygieneShield Manual

Also See for ATP 6100I:

Advertisement

Beko ATP 6100I - Air Purifier with HEPA Filter and HygieneShield Manual

Meanings of the Symbols

Following symbols are used in various sections of this user manual:

information Important information and useful hints about usage.
warning
Warnings against dangerous situations concerning the security of life and property.
Electrical insulation class.

How The Unit Works

The air purifier removes up to 99.97% of airborne allergens as small as 0.3 microns, including ragweed pollen, grass pollen, tree pollen, household dust, dust mite debris, pet dander, smoke and odour from the air passing through the filter.

Know Your Product

Know Your Product

Control Panel Introduction

Control Panel Introduction

Operating Instructions

İmportant notes

  • Carefully unpack your air purifier.
  • Select a firm level place where there are no obstructions to the air inlet grill or air outlet.
  • Remove all PE bags from filters before use.
  • Do not point air outlet towards wall.

Controls Introduction

Power button
Touch the Power button, the machine will start running under the default "AUTO" setting, and the indicator of "AUTO" setting will illuminate.

Fan speed button
There are 4 speed settings including Low, Medium, High and AUTO for selection. Touch the Fan speed button to select your desired speed setting. Timer button The timer allows you to run your air purifier at your convenience, for up to 8 hours. With 3 settings including 2hr, 4hr and 8hr.

Dust sensor
This Air Purifier has a built-in smart dust sensor which can detect the air quality of current environment automatically, and the air quality can be shown by the air quality indicator which can illuminate in blue, pink and red when the air quality is very good, good and bad accordingly.

Ionizer rocker switch
This appliance has an independent Ionizer rocker switch equipped at the bottom of body, feature which, when turned on, releases negative ions into outgoing filtered air to help the air purification process. Remove top body Fig. 1
Using the Ionizer rocker switch

To Operate Your Device

  1. Connect the appliance with power source, one "Beep" can be heard.
  2. Touch the Power button once, "Beep" can be heard, the appliance starts to run under under the default "AUTO" setting, its corresponding indicator will illuminate, and the air quality indicator will illuminate in blue, pink or red according to the actual air quality.
    Air quality indication

information NOTE: Hold and Touch the "Power button" for 2 seconds if you want to enter into the sleep mode. To recover, hold and Touch the "Power button" for 2 seconds again.

  • Very good air quality: The air quality indicator illuminates in blue.
  • Good air quality: The air quality indicator illuminates in pink.
  • Bad air quality: The air purifier illuminates in red.
  1. And you can select your required speed setting by following the operation described in "CONTROLS INTRODUCTION". After select, the corresponding indicator of selected speed setting will turn on.
  2. After turn on the air purifier and select your required speed setting, you can activate the timer by following the operation as below: Touch down Timer button on the control panel, one beep "Beep" can be heard. There are 3 settings including 2H, 4H and 8H for selection. After select your required timing, the indicator of selected timing will illuminate. When the timer expires, the air purifier will power off automatically and the indicator of selected timing will extinguish.
  3. When the filter change indicator illuminates in white, it is time to change the HEPA filter. Please change the HEPA filter by following the operation described in the section of "CHANGE THE HEPA FILTER".

Change The Hepa Filter

Always unplug the unit before changing the HEPA filter.

  1. When the filter change indicator illuminates in white, it's time to change the HEPA filter.
  2. Turn off the unit and unplug it.
  3. Carefully rotate the body anticlockwise and remove it from the air inlet grill.
  4. Remove the HEPA filter out of the air inlet grill.
  5. Remove the pre-filter.
  6. Replace a new HEPA filter into the air inlet grill.
  7. Put the body onto the air inlet grill, then rotate the body clockwise until the fastener locks into the groove.
  8. Simultaneously hold and Touch the Power and Timer buttons for 3 seconds to activate the filter function.

Troubleshooting

Problem Solution

Unit will not operate

  • Check to make sure the unit is plugged in.
  • Check to make sure the unit is on.
  • Check condition of the filter and replace if necessary.
  • Check to ensure nothing is blocking the air inlet and filtered air outlet.
  • Be sure the plastic bag has been removed from the filter.

Decreased air flow

Technical Data

Technical and design modifications reserved.
Made in P.R.C.
Model No. ATP6100I
Power supply 100-240V~, 50-60Hz
Rated power 21.6 W
Contact details for obtaining more information Arcelik A.S. Sutluce, Karaagac Cad. 2-6, 34445 Beyoglu Istanbul Turkey
Electrical insulation class: II
Parameter of External Power Supply
Manufacturer Debom Technology Co.,Ltd.
Model Identifier DBS024A-1201800G
Input Voltage 100-240V~
Input Frequency 50-60Hz
Input Current 0.8A Max
Output Voltage 12.0V DC
Output Current 1.8A
Output Power 21.6W
Average active efficiency 88,03%
Efficiency at low load (10%) 79,98%
No-load power consumption 0.070W

Important Safety Instructions

General Safety

  • Check if the voltage indicated on the appliance corresponding to the local mains voltage before you connect the appliance.

  • To avoid fire hazard, never put the cord under rugs, or near any heat source.
  • Carefully discard any plastic wrapping that was used for the packaging.
  • Do not use the air purifier outside.
  • Do not place the unit near any heat source or in direct sunlight.
  • Always unplug the air purifier before removing the grill, changing the filters, cleaning the air purifier or whenever it is not in use.
  • Do not use in or around water or any other liquids. Do not attempt to wash the unit under running water.
  • Use appliance only for intended household use as described in this manual.
  • Ensure that all air openings are not restricted or covered in any way.
  • Do not place anything on top of the unit.
  • Never insert any object into any openings.
  • Do not use the air purifier if any part is missing or damaged in any way.
  • Do not attempt to repair or adjust any mechanical functions of this unit. If the unit becomes damaged call the service number on the back of this manual.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • The air purifier contains no user serviceable parts and should the product suffer damage or breakdown call the service number on the back of this manual.
  • Should the air purifier stop working, first check the fuse/circuit breaker at the distribution board is operating, before contacting the place of purchase.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • This appliance is intended to be used in household and similar applications such as:
    • Staff kitchen areas in shops, offices and other working environments;
    • Farm houses;
    • By clients in hotels, motels and other residential type environments;
    • Bed and breakfast type environments.
  • Save these instructions

burn hazardburn hazard
To prevent risk of electric shock, remove cord plug from outlet before activating the appliance. To prevent risk of fire, inspect and clean equipment regularly as noted in this manual.

  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

Cleaning And Maintenance

  1. Turn the air purifier off and unplug it before cleaning.
  2. The outside of the air purifier can be cleaned with a soft, clean dampened cloth.
  3. The air outlet and air inlet grill can be cleaned of dust with a small, soft brush.
  4. If you wish to clean the inside of the air purifier, please only use a dry, soft cloth to wipe it down.
  5. Wash the Pre-filter by following the operation described in the section of "VACUUM OR WASH THE PRE-FILTER".
  6. Do not wash the HEPA filter.


Do not allow moisture to come in contact with the body of the air purifier.

Vacuum Or Wash The Pre-filter

Occasionally vacuum the exterior of the fabric pre-filter to remove dust.
Always unplug the unit before removing the fabric pre-filter.

  1. Carefully rotate the body anticlockwise and remove it from the air inlet grill.
  2. Remove the pre-filter from the HEPA filter.
  3. Wash the pre-filter in the washing machine.
  4. After the pre-filter is cleaned well and dried, attach the pre-filter onto the HEPA filter.
  5. Carefully put the HEPA filter with pre-filter into the air inlet grill.
  6. Put the body onto the air inlet grill, then rotate the body clockwise until the fastener locks into the groove.
    Washing The Pre-filter

Plug Wiring

The moulded plug on this appliance incorporates a 13 A fuse. Should the fuse need to be replaced an ASTA approved BS1363 fuse of the same rating must be used. Do not forget to refit the fuse cover. In the event of losing the fuse cover, the plug must not to be used until a replacement fuse cover has been fitted.
Colour of the replacement fuse cover must be the same colour as that visible on the pin face of the plug Fuse covers are availabe from any good electrical store.

Fiting a different plug

  • As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals on your plug, proceed as follows:
  • Brown cable = L (Live)
  • Blue cable = N (Neutral)
  • Green/yellow cable must be connected to ground (E) line
  • With the alternative plugs a 13 A fuse must be fitted either in the plug or adaptore or in the main fuse box. If in doubt contact a qualified electrician.

Product Guarantee

Guarantor: Beko plc, 1 Greenhill Crescent, Watford, Hertfordshire. WD18 8UF

Please call our UK based Customer Service department if you need help or advice from us:

United Kingdom and Northern Ireland: 0333 207 9710
Republic of Ireland: 01 862 3411
You can also contact us through our website: www.beko.co.uk

Product registrations
Please visit:

UK: www.beko.co.uk/register
Ireland: www.beko.ie/register

www.beko.co.uk

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Beko ATP 6100I - Air Purifier with HEPA Filter and HygieneShield Manual

Advertisement

Need Assistance?

Do you have a question about the ATP 6100I that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents