Precautions
CE
el
Environment
Avoid
using
the deck
in the following
conditions:
eAt
high temperatures
(near a heater,
exposed to direct sunlight, etc.).
© At extremely low temperatures.
«Where there is excessive humidity.
e In a dusty atmosphere.
Where power line voltage fluctuations are
severe (the use of a voltage regulator may
be advisable),
Cassette Tape (Fig. 3)
Tape Selection:
For the automatic tape select function to
work properly, metal and chrome (cobalt)
'tapes must have tape identification holes.
Tape Handling:
Do not store tapes in the following places:
On top of heaters, exposed to direct sun-
light or in any other places with high
temperatures,
Near speakers, on TV sets or amplifiers,
or where they would be exposed to strong
magnetic fields,
Where
humidity
is high and in dirty,
dusty places.
Avoid dropping or subjecting cassettes to
excessive shocks.
Voltage
Conversion
(For general export
models) (Fig. 6)
If it is necessary to change the voltage
selector of the deck to be suitable for your
area, use the following procedure:
1. DISCONNECT
THE
POWER
LINE
CORD.
2. Using a screwdriver, turn the selector
until
the
required
voltage
marking
appears.
IMPORTANT (for U.K. Customers)
'The wires in this mains lead are coloured
ein accordance with the: following code:
BLUE:
NEUTRAL
eat as follows: -
=
S
'The wire which is coloured BLUE must
he connected to the terminal which is
marked with the letter N or coloured
BLACK. The wire which is coloured
BROWN
must be connected to the
aor which is
In the U. K, thi ; unit is sold without Le
AC plug,
THE APPLIANCE CONFORMS WITH
EEC
DIRECTIVE
87/308/EEC
RE-
GARDING
INTERFERENCE
SUuP-
PRESSION
* Dolby noise reduction
and HX Pro
headroom extension manufactured under
license from Dolby Laboratories Licensing
Corporation. HX Pro originated by Bang
and Olufsen.
"DOLBY", the double-D symbol OO and
"HX PRO" are trademarks
of Dolby
Laboratories Licensing Corporation.
Features and Controls (Fig. 1)
Front Panel
@ POWER Switch
Press to switch the deck on, The display
window will be illuminated, Press again to
turn the deck off.
Note: When switching the power on again
after switching it off, be sure to wait for
more than 3 seconds.
@ REMOTE SENSOR (Remote Con-
trol Infrared Signal Receptor)
This receives signals from the provided RC-
394
(V-7010)/RC-393
(V-5010)
infrared
remote control unit.
© Linear Counter
Indicates recording and playback time in
minute and second.
Q Mode Indicator
CD SYNC:
Lights when CD synchro
start is activated,
REC:
Lights in the recording mode
and
flickers during record-
muting.
PLAY:
Lights during playback and
recording.
PAUSE:
Lights
when
the
tape
is
stopped temporarily.
@ CLEAR Button
Pressing the CLEAR button resets the
linear counter
to zero
(0000). Press this
button before starting recording or play-
back.
@ TAPE LENGTH Button
Set this to minimize the error in the counter
reading. (See page 7.)
@ RTZ Button
If this button is pressed, the tape is fast-
forwarded
or rewound
until a counter
reading of OOMOOS
is reached, then the
deck stops. (See page 9.)
© Cassette Holder
Load the cassette here.
Connections (Fig. 2)
eTurn
off the power
of all equipment
before making connections.
Read the instructions of each component
you intend to use with the deck,
© AUTO MONITOR Button
To change
the monitor
mode
between
source and tape, press this button. The
monitor mode is automatically selected in
accordance with the tape operation,
@ MPX FILTER Button
Press this button when making a recording
of an FM broadcast using Dolby NR, the
indicator lights. This eliminates the pilot
tone (19 kHz) and subcarrier tone (38 kHz)
of the FM broadcast which could affect
operation
of the Dolby
noise
reduction
system. To release this function, press the
MPX FILTER button again,
@ DOLBY NR Selector
OFF: Set to this position when you do not
want
to
use
any
noise
reduction
system.
DOB: Set to this position when making a
recording using the Dolby B noise
reduction
system,
or playing back
tapes recorded with Dolby B NR.
DUOC: Set to this position when making a
recording
using the Dolby C noise
reduction
system,
or playing back
tapes recorded with Dolby C NR.
© Multi-Display Window
@ PEAK LEVEL METER
This meter shows the peak level of the
input
or playback
signal. The
meter
has a peak hold feature; when the level
exceeds -7 dB, the peak level is held for
approx. 2 seconds.
Tape Type Indicator
Tape
type
indicator above
the meter
indicates the type of tape being used,
The
V-7010V-5010
has an auto tape
selector function, with which the NOR-
MAL, CrO, or METAL indicator lights
when a tape is loaded,
© CALIBRATION Indicator
Lights
together
with
"LEVEL/BIAS"
in the calibration mode.