NOTE
SPECIFICATIONS
AUDIO SIGNAL GENERATOR
(AG)
SOLID STATE VOLT METER
(SSVM)
Ranges:
0.3 mV ~ 100V (full scale)
Frequency response:
5 Hz ~ 500 kHz
Impedance:
1 M-ohms or more
STANDARD
SIGNAL GENERATOR
(RF-SG)
Ranges:
90 MHz ~ 108 MHz
150 kHz~ 1,500 kHz
Modulation
frequency:
1 kHz, 400 Hz or external
input
(input level:
2V or less)
Distortion
(internal):
0.5% or less
OSCILLOSCOPE
(SCOPE)
Ranges:
DC ~ 10 MHz
Sensitivity:
20 mV/cm
Impedance:
1 M-ohms
or more
MULTIPLEX
SIGNAL
GENERATOR
(MPX-SG)
Modulation frequency:
1 kHz or external input
(input level: 5V or less)
Separation:
60 dB or more
S/N:
*
85 dB or more
FREQUENCY
COUNTER
(COUNTER)
Frequency response:
10 Hz ~ 1 MHz
Sensitivity:
50 mV or more
Impedance:
1 M-ohms or more
DISTORTION
METER
Ranges:
0.1% ~ 0.03% (full scale)
Sensitivity:
100 mV or more
Dummy
ant.
© LFFSG WS
@ [mex-sc}—{
RF-sc |}
® [LAF-SG FW
@j[score |
DISTORTION
METER
@
8
1
ICg3
12
9
16
TP1
Frequency
counter
DC voit meter
Left (Right)
ADJUSTMENT
vRmt1
(L)
VRm2
(R)
Lg7
Lg4
Lg2
[am osc]
osc
frm 1FT|
1FT
[Fm anT]
ANT
CTg95
Lg5
lg
Lg11
CTg3
CTg1
CTg4
CTg2
VRg2
Lg8
[SEPARATION]
[em iT]
FT
13