English Product Specific Applications For All Product Applications Refer to ladder instructions for Safe-T Ladder Extension may be used in information regarding maximum user accordance with: weight. OSHA 1926.1053(b)(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper Worker Classifications landing surface to which the ladder is used to gain...
English Compatibility Maintenance, Cleaning, and Storage The Safe-T Ladder Extension is designed to attach to compatibly sized extension ladders to Cleaning after use is important for maintaining provide a positive handhold for safe transition the safety and longevity of the Safe-T Ladder between a ladder and roof or other compatible Extension.
6 in (152 mm) Handholds 53 in (1.35 m) Thumb Screw Knobs Locking Levers Specifications Materials Extends 3' (0.9 m) beyond end of ladder Powder-coated aluminum Weight: 15 lb (6.8 kg) Part # Description 10800 Safe-T Ladder Extension...
Installation and Use Compatible Ladder Dimensions Prior to Installation: Side rail width: 0.5 - 1.375 in (13 - 35 mm) Install Rail Extensions while ladder is on the ground. Tighten knobs as securely as possible by hand to prevent Rail Extensions Side rail depth: 3 - 3.5 in (76 - 89 mm) from disengaging.
Page 6
Installation and Use (cont'd) Step 1 Step 2 Ensure both spring-loaded locking levers on Tighten thumb screws to secure Safe-T Ladder Safe-T Ladder Extension MUST fully lock under Extension to ladder. Always install Safe-T Ladder top rung of ladder. Extension so that thumb screw knobs are on climbing side of the ladder.
Page 7
Installation and Use (cont'd) When in use, top rung of ladder must be at roof line. Safe-T Ladder Extensions are NOT load-bearing and must NEVER rest against roof/ upper surface edge! CIRCLE-X WARNING Top rung of ladder is NOT at roof CIRCLE-C edge! Top rung of ladder...
English Safety Information Harnesses and connectors selected must be compliant with manufacturer’s instructions, and WARNING! Failure to understand and must be of compatible size and configuration. comply with safety regulations may result Snap hooks, carabiners, and other connectors in serious injury or death. Regulations must be selected and applied in a compatible included herein are not all-inclusive, are fashion.
When lowering fly section never allow any portion of Rail Extensions to come in contact with lower ladder section to prevent Rail Extensions from falling. Do not let Rail Extensions come in contact with electrical wires. Guardian Inspect for damage prior to each use and immediately Attach Safe-T Ladder remove from service in event of failed inspection.
Inspection Prior to EACH use, inspect Safe-T Ladder Extension for deficiencies, including, but not limited to, corrosion, deformation, pits, burrs, rough surfaces, sharp edges, cracking, rust, paint buildup, excessive heating, alteration, and missing or illegible labels. IMMEDIATELY remove Safe-T Ladder Extension from service if defects or damage are found, or if exposed to impact forces.
Inspection Log Serial No: Date of first issue: Model #: User: Date: Results/Condition: Inspected by: Next Inspection Date:...
Page 12
This warranty is not transferable to any other Guardian service and does not apply to product that is resold after having been put into service. No other person, firm, entity, or the like is authorized to assume or assign for Guardian any other liability in connection with the sale or use of Guardian’s products.