LED SMT Reflow Oven T-980 User Manual LED SMT Reflow Oven Model: T-980 Shandong Puhui Electric Technology Co., Ltd http://www.te168.com Https://www.te168.com 1/11...
Page 2
LED SMT Reflow Oven T-980 User Manual Features: 1. T-980 selects the IR and hot air heating technology controlling, equipped with special design wind wheel, speed stability and uniform temperature, suit for uninterrupted soldering the LED and BGA components. 2. Equipped with the crawler-type and 8 temperature-zone heating systems, each...
LED SMT Reflow Oven T-980 User Manual Technical parameters T-980 Model The heating zone quantity Upper5/down3 The length of the heating zone 1160mm The heating type IR and hot air heating The cooling zone quantity 400mm Maximum width of PCB The operation direction left→right...
LED SMT Reflow Oven T-980 User Manual Description of the main parts 1. Welding table main body Exhaust pipe joint Emergency stop button Cooling fan Status indicator lamp 2.Control panel Start button Stop button 3.The instruction of the connecting line...
Page 5
LED SMT Reflow Oven T-980 User Manual When the power cord is connected, power on the circuit breaker. 4.Status indicator lamp When the status indicator is green, it means that the temperature zone is in heating state; when the status indicator is red, it means that all the temperature zones are not in heating state.
Page 6
LED SMT Reflow Oven T-980 User Manual Return To calibrate the temperature of the machine, input the current room temperature in the dialog box when the internal temperature of the machine is consistent with the room temperature, click "save" to finish the room temperature calibration, and click the back button to enter the main menu interface.
Page 7
LED SMT Reflow Oven T-980 User Manual Preset temp Temp alarm indicator Actual temp When the actual operating temperature of the temperature zone exceeds the set temperature of the temperature zone by 20°C, the temperature alarm indicator will flash red and green alternately. During the heating process and the normal temperature control temperature alarm indicator shows green.
Page 8
LED SMT Reflow Oven T-980 User Manual 5. Click the "Time Setting" button to enter the following interface: By dragging the ruler slider left and right to change the PCB run time, the run speed of the belt can be changed.
Page 9
LED SMT Reflow Oven T-980 User Manual interface has an indicator light to indicate), the power should be cut off to prevent damage to the circuit board and chip;Adjust the temp curve when the temp is stable. ⑤.At present, there are many kinds of solder production and use, and each company chooses different ones.
LED SMT Reflow Oven T-980 User Manual no reflow, to operate as step 4. If the reflow is too fast, please keep correct p roportion to increase or reduce the temperature. And let the PCB pass the syst em again until reach the reflow critical point. Then turn to step 4, only when there is reflow that is good.
LED SMT Reflow Oven T-980 User Manual net-belt position. Cannot make it be lock or fall off. Ensure the machine is stable, not lean or unstable. Adjust the leg under the 4.6. machine to keep the transmission horizontal. Or the PCB will shift in the transmit process.