Tetra GEPS12W-60 Installation Manual

Led systems power supply

Advertisement

LED Systems Power Supply
GEPS12W-60 (100-240 VAC input/12VDC output/60W)

Power Supply Features

• Supports all 12 VDC Tetra Products
• UL: Class 2
• 100-240 VAC Input

BEFORE YOU BEGIN

Read these instructions completely and carefully.
RISK OF ELECTRIC SHOCK
• Disconnect power at fuse box or circuit breaker before servicing or
installing product.
• Properly ground Tetra
power supply.
®
RISK OF FIRE
• Minimum 10 cm (4") to side and 2.5 cm (1") spacing in
compartment surrounding component required.
• Use only approved wire for input/output connection. Minimum size
18 AWG (0.82 mm
).
2
• Follow all local codes.
• Application considerations potentially requiring additional spacing
include high ambient temperature seen by the power supply, poor
contact with a heat dissipating material, inadequate ventilation, or
direct exposure to sun.
RISK INJURY
• While performing installations described, gloves, safety
glasses or goggles should be worn.

Prepare Electrical Wiring

Electrical Requirements

• Acceptable for use in dry, damp and wet locations.
• The grounding and bonding of the LED Driver shall be
done in accordance with National Electric Code (NEC)
Article 600.
• Follow all National Electric Codes (NEC) and local codes.
WARNING / AVERTISSEMENT
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l'alimentation électrique à la boîte de fusibles ou au disjoncteur avant
l'entretien ou l'installation du produit.
• Assurez-vous de correctement mettre à terre le bloc d'alimentation Tetra
RISQUES D'INCENDIE
• Un espacement minimum de 10 cm (4 po) entre 2 alimentations de
puissance est requis ainsi qu'un espacement minimal de 2,5 cm (1 po)
avec toute enceinte.
• N'utilisez que des fils approuvés pour les entrées/sorties de connexion.
Taille minimum 18 AWG (0.82 mm
• Respectez tous les codes locaux.
• Certaines applications pourraient requérir un espacement additionnel, p.
ex. une température ambiante élevée autour du bloc d'alimentation, un
mauvais contact avec une matière dissipatrice de chaleur, une ventilation
inadéquate ou une exposition directe au soleil.
CAUTION / ATTENTION
RISQUES DE BLESSURE
• Lors de l'exécution des installations décrites, des gants, des lunettes
de sécurité ou des lunettes de protection doivent être portées.
Save These Instructions
FOR UL ONLY
For the latest North American install guides for your product
go to: https://products.LED.com/led-signage-lighting
).
2
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Installation Guide
SIGN186 | GE2022-3612
12
12
Volt
.
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GEPS12W-60 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tetra GEPS12W-60

  • Page 1 • Disconnect power at fuse box or circuit breaker before servicing or • Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant installing product. l’entretien ou l’installation du produit. • Assurez-vous de correctement mettre à terre le bloc d’alimentation Tetra • Properly ground Tetra power supply. ®...
  • Page 2 Tetra Power Supply GEPS12W-60 Installation Guide ® Power Supply Installation Power Supply NOTE: All electrical connections Green with Power Supply should be made within the letter. input wires White (+) yellow stripe Red (+) To power supply Conduit Black (-)
  • Page 3 » If there is no AC voltage, correct the upstream AC issue. Some LEDs appear dim • Ensure the overall length of the Tetra LED System does not exceed the maximum load. ® • Ensure the length of supply wire is equal to or below the recommended remote mounting distance.

Table of Contents