Do you have a question about the LOG200 and is the answer not in the manual?
Questions and answers
Summary of Contents for Praxisdienst LOG200
Page 1
LOG200 / LOG210 / LOG220 Datenlogger für Temperatur, Feuchte* und Druck** Data logger for temperature, humidity* and pressure** Enregistreur de température, d’humidité* et de la pression** 5005-0200 / 5005-0210 / 5005-0220 *nur / only / uniquement LOG210/LOG220 **nur / only / uniquement...
Page 2
Fig. A Fig. C LOG220_16099908_2016-09-27T103123.PDF LOG220 SN 16099908 V 04.00 TEST LOG220 Test FW 4.00 Beta 20.10.2016 Konfiguration/Configuration Benutzer/Operator Intervall/Interval 00:00:30 Start möglich durch/Start possible by Taste/Button Startverzögerung/Start delay 00:00:00 Stopp möglich durch/Stop possible by Verbindung/USB connect Alarmverzögerung/Alarm delay 00:00:00 Alarm unten/Alarm low Alarm...
Battery replacement / Battery status indication 4. Equipment and usage 5.8.1 Set Date and Time after battery replacement via button 28 LOG200/LOG210/LOG220 series logger are suitable for recording, Alerts alarm tracking and displaying of temperature, humidity*, dew point 6. Technical data temperature* and barometric** (*only LOG210/220,** only LOG220) 7.
9. lockable wall holder 5. Sensor compartment Recording Interval: 5 min. LOG210/ LOG220, Fig. B (see page 2) 15 min. LOG200 Battery indication, 1. Units of measurement line 1 Measuring interval: During recording the measurement interval and 2. Measurement line 1...
Page 5
The logger is still active, only the display is switched off. The internal clock runs. 5.2.2 Windows Software for Log200-Series The instruments of series Log200 are already preset and ready for start. It can be used without any software! However, there is a Windows Application free for downloading.
Now the logger is stopped. MOV: Indicates whether instrument has been moved (with date and time) The Logger is shown as removable drive LOG200/LOG210/ LOG220 Signature: Sign PDF if required. : Measurement OK : Measurement failed View PDF and save. PDF will be overwritten 5.6 USB-Connection...
Page 7
Auto-Mode (automatic measurement switching of measurement line 2) tery cover on the rear side. Therefore you LOG200: By pressing the Mode-button until Auto appears in the have to turn the battery cover 20° to the left. measurement line 2 the Minimum (MIN)- and Maximum (MAX) Use a coin to open/close the battery lid.
Page 8
After battery replacement or power interrupt the instrument automa- dostmann-service.de , select Downloads/Software/5005-0200_ tically changes into the configuration mode to set date, time and LOG200/Software/ interval. If no button will be pressed for 20 seconds the unit pro- ceeds with the last date and time in memory: 6. Technical data →...
As a consumer, you are legally required to take them to your 5.2.1.1 Mode d’affichage Power-Save retail store or to an appropriate collection site depending on nati- 5.2.2 Logiciel Windows pour LOG200 onal or local regulations in order to protect the environment. The symbols for the heavy metals contained are: 5.2.2.1 Logiciel de configuration Log Connect...
Need help?
Do you have a question about the LOG200 and is the answer not in the manual?
Questions and answers